Performance of the HiberGene Group B Streptococcus kit, a loop-mediated isothermal amplification–based assay for GBS screening during pregnancy

Timely and accurate detection of Group B Streptococcus (GBS) carriage in pregnant women allows for targeted peripartum prophylaxis. Replacing culture-based screening by molecular biology assays enables faster results obtention, better targeted antibiotic prophylaxis, and reduces the laboratory workl...

Descripción completa

Detalles Bibliográficos
Autores principales: Tittel-Elmer, Mireille, de Tejada, Begoña Martinez, Renzi, Gesuele, Schrenzel, Jacques
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9836968/
https://www.ncbi.nlm.nih.gov/pubmed/36449147
http://dx.doi.org/10.1007/s10096-022-04534-0
Descripción
Sumario:Timely and accurate detection of Group B Streptococcus (GBS) carriage in pregnant women allows for targeted peripartum prophylaxis. Replacing culture-based screening by molecular biology assays enables faster results obtention, better targeted antibiotic prophylaxis, and reduces the laboratory workload. Here, we present a comparative analysis between a Loop Mediated Isothermal Amplification assay (HiberGene GBS kit) and culture (gold-standard). The HiberGene GBS kit showed a sensitivity of 97.9% and a specificity of 96.8% compared with culture. The limit of detection was estimated at 10(3) cfu/ml and results were obtained within 30 min. HiberGene GBS assay can be used for peripartum GBS screening and targeted antibiotic prophylaxis provided sample processing can be swiftly performed around the clock.