Cargando…

Treating Inferior Pole Fracture of Patella with Hand Plating System: First Clinical Results

OBJECTIVE: Inferior pole fractures of patella are notorious fractures where it is difficult to obtain rigid internal fixation by conventional methods. The objective of the study was to introduce the Hand Plating System (HPS), which was a novel surgical technique for inferior pole fractures of patell...

Descripción completa

Detalles Bibliográficos
Autores principales: Ma, Xiang‐Yu, Cui, Dong, Liu, Bing, Wang, Zheng, Yu, Hai‐Long, Yuan, Hong, Xiang, Liang‐Bi, Zhou, Da‐Peng
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley & Sons Australia, Ltd 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9837230/
https://www.ncbi.nlm.nih.gov/pubmed/36331126
http://dx.doi.org/10.1111/os.13539
_version_ 1784869032283865088
author Ma, Xiang‐Yu
Cui, Dong
Liu, Bing
Wang, Zheng
Yu, Hai‐Long
Yuan, Hong
Xiang, Liang‐Bi
Zhou, Da‐Peng
author_facet Ma, Xiang‐Yu
Cui, Dong
Liu, Bing
Wang, Zheng
Yu, Hai‐Long
Yuan, Hong
Xiang, Liang‐Bi
Zhou, Da‐Peng
author_sort Ma, Xiang‐Yu
collection PubMed
description OBJECTIVE: Inferior pole fractures of patella are notorious fractures where it is difficult to obtain rigid internal fixation by conventional methods. The objective of the study was to introduce the Hand Plating System (HPS), which was a novel surgical technique for inferior pole fractures of patella, and to report the radiological and clinical outcomes following the application of the surgical technique. METHODS: The study was designed as a retrospective cohort study. Between July 2017 and December 2018, 30 patients who were diagnosed with inferior pole fracture of the patella without additional orthopaedic injuries were enrolled in this case series. After X‐ray and 3D‐CT examinations, all patients underwent open reduction and internal fixation by HPS with or without supplementary cannulated screw and lag screw stabilization. The bony union time, final range of motion (ROM), Bostman score, visual analog scale (VAS), and complications were measured as the clinical outcomes under a minimum of 12 months of follow‐up. RESULTS: All of the operations went well with the mean operative time of 76.2 ± 15.3 min. Bony union achieved in all the cases at an average of 9.5 ± 1.4 weeks after surgery. There was no loss of reduction, fixative failure, or surgical implant removal during follow‐up. The average range of motion 1 year postoperatively was 0°–123.3°. The mean Bostman Score at the last follow‐up was 26.8 ± 2.1 with the satisfactory rate of 100%. The pain feeling during walking as measured by VAS averaged at 0.9 ± 1.3. No complications developed except for one case of poor incision healing, which healed eventually after surgical debridement. CONCLUSIONS: HPS was demonstrated as a secure fixation and as a kind of tension band for inferior pole fractures of the patella. Satisfactory recovery of knee function and low complication rate, including no need for hardware removal, could be expected.
format Online
Article
Text
id pubmed-9837230
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher John Wiley & Sons Australia, Ltd
record_format MEDLINE/PubMed
spelling pubmed-98372302023-01-18 Treating Inferior Pole Fracture of Patella with Hand Plating System: First Clinical Results Ma, Xiang‐Yu Cui, Dong Liu, Bing Wang, Zheng Yu, Hai‐Long Yuan, Hong Xiang, Liang‐Bi Zhou, Da‐Peng Orthop Surg Research Articles OBJECTIVE: Inferior pole fractures of patella are notorious fractures where it is difficult to obtain rigid internal fixation by conventional methods. The objective of the study was to introduce the Hand Plating System (HPS), which was a novel surgical technique for inferior pole fractures of patella, and to report the radiological and clinical outcomes following the application of the surgical technique. METHODS: The study was designed as a retrospective cohort study. Between July 2017 and December 2018, 30 patients who were diagnosed with inferior pole fracture of the patella without additional orthopaedic injuries were enrolled in this case series. After X‐ray and 3D‐CT examinations, all patients underwent open reduction and internal fixation by HPS with or without supplementary cannulated screw and lag screw stabilization. The bony union time, final range of motion (ROM), Bostman score, visual analog scale (VAS), and complications were measured as the clinical outcomes under a minimum of 12 months of follow‐up. RESULTS: All of the operations went well with the mean operative time of 76.2 ± 15.3 min. Bony union achieved in all the cases at an average of 9.5 ± 1.4 weeks after surgery. There was no loss of reduction, fixative failure, or surgical implant removal during follow‐up. The average range of motion 1 year postoperatively was 0°–123.3°. The mean Bostman Score at the last follow‐up was 26.8 ± 2.1 with the satisfactory rate of 100%. The pain feeling during walking as measured by VAS averaged at 0.9 ± 1.3. No complications developed except for one case of poor incision healing, which healed eventually after surgical debridement. CONCLUSIONS: HPS was demonstrated as a secure fixation and as a kind of tension band for inferior pole fractures of the patella. Satisfactory recovery of knee function and low complication rate, including no need for hardware removal, could be expected. John Wiley & Sons Australia, Ltd 2022-11-04 /pmc/articles/PMC9837230/ /pubmed/36331126 http://dx.doi.org/10.1111/os.13539 Text en © 2022 The Authors. Orthopaedic Surgery published by Tianjin Hospital and John Wiley & Sons Australia, Ltd. https://creativecommons.org/licenses/by-nc/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
spellingShingle Research Articles
Ma, Xiang‐Yu
Cui, Dong
Liu, Bing
Wang, Zheng
Yu, Hai‐Long
Yuan, Hong
Xiang, Liang‐Bi
Zhou, Da‐Peng
Treating Inferior Pole Fracture of Patella with Hand Plating System: First Clinical Results
title Treating Inferior Pole Fracture of Patella with Hand Plating System: First Clinical Results
title_full Treating Inferior Pole Fracture of Patella with Hand Plating System: First Clinical Results
title_fullStr Treating Inferior Pole Fracture of Patella with Hand Plating System: First Clinical Results
title_full_unstemmed Treating Inferior Pole Fracture of Patella with Hand Plating System: First Clinical Results
title_short Treating Inferior Pole Fracture of Patella with Hand Plating System: First Clinical Results
title_sort treating inferior pole fracture of patella with hand plating system: first clinical results
topic Research Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9837230/
https://www.ncbi.nlm.nih.gov/pubmed/36331126
http://dx.doi.org/10.1111/os.13539
work_keys_str_mv AT maxiangyu treatinginferiorpolefractureofpatellawithhandplatingsystemfirstclinicalresults
AT cuidong treatinginferiorpolefractureofpatellawithhandplatingsystemfirstclinicalresults
AT liubing treatinginferiorpolefractureofpatellawithhandplatingsystemfirstclinicalresults
AT wangzheng treatinginferiorpolefractureofpatellawithhandplatingsystemfirstclinicalresults
AT yuhailong treatinginferiorpolefractureofpatellawithhandplatingsystemfirstclinicalresults
AT yuanhong treatinginferiorpolefractureofpatellawithhandplatingsystemfirstclinicalresults
AT xiangliangbi treatinginferiorpolefractureofpatellawithhandplatingsystemfirstclinicalresults
AT zhoudapeng treatinginferiorpolefractureofpatellawithhandplatingsystemfirstclinicalresults