Cargando…

Novel Three‐Holed Titanium Plate Fixation during Open Door Laminoplasty for Cervical Spondylotic Myelopathy: Comparison with Conventional Titanium Plate

OBJECTIVE: For reconstructing the posterior cervical muscular–ligament complex, attachment points and various modified techniques were designed and applied in clinical practice. This study investigated the clinical and radiographic outcomes of open door laminoplasty with modified centerpiece mini‐pl...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Fa‐jing, Liu, Yan‐cheng, Hu, Yong‐cheng, Ding, Xiao‐kun, Miao, Jun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley & Sons Australia, Ltd 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9837288/
https://www.ncbi.nlm.nih.gov/pubmed/36419321
http://dx.doi.org/10.1111/os.13551
_version_ 1784869046615801856
author Liu, Fa‐jing
Liu, Yan‐cheng
Hu, Yong‐cheng
Ding, Xiao‐kun
Miao, Jun
author_facet Liu, Fa‐jing
Liu, Yan‐cheng
Hu, Yong‐cheng
Ding, Xiao‐kun
Miao, Jun
author_sort Liu, Fa‐jing
collection PubMed
description OBJECTIVE: For reconstructing the posterior cervical muscular–ligament complex, attachment points and various modified techniques were designed and applied in clinical practice. This study investigated the clinical and radiographic outcomes of open door laminoplasty with modified centerpiece mini‐plate fixation and extensor attachment point reconstruction in the treatment of cervical spondylotic myelopathy (CSM). METHODS: Sixty‐nine patients with CSM who underwent C3–C7 open door laminoplasty at our hospital from January 2016 to May 2018 were divided into two groups: 37 and 32 patients underwent laminoplasty with modified and conventional centerpiece titanium plate fixation (MPF and CPF groups), respectively. Changes in cervical spinal angle (CSA), cervical range of motion (ROM), posterior cervical muscle atrophy, neurological function (Japanese Orthopaedic Association [JOA] score), Neck Disability Index (NDI), and axial symptom severity were compared between the two groups. RESULTS: There were no significant differences in operative duration (136.7 ± 23.9 vs 128.3 ± 21.5 min, t = 1.525, p > 0.05), volume of intraoperative blood loss (275.9 ± 33.1 vs 268.2 ± 31.6 ml, t = 0.984, p > 0.05), lamina open angle (41.2° ± 4.5° vs 39.4° ± 4.1°, t = 1.726, p > 0.05), and spinal cord drift distance (2.4 ± 0.3 vs 2.3 ± 0.4 mm, t = 1.184, p > 0.05) between the two groups. After surgery, JOA score significantly increased (p < 0.05), and neurological recovery rates were similar (62.7% vs 63.4%, t = 0.208, p > 0.05). The NDI score was significantly decreased in both the groups (p < 0.05); however, the MPF group recovered to a greater degree than the CPF group (8.3 ± 1.2 vs 9.8 ± 1.4) (t = 4.793, p < 0.05). There was no significant change in cervical ROM postoperatively compared with preoperatively in either group (p > 0.05). CSA decreased from 21.7° ± 2.8° to 18.3° ± 2.1°, and posterior cervical muscle cross‐sectional area decreased from 35.2 ± 4.9 cm(2) to 31.0 ± 4.1 cm(2) in the CPF group (p < 0.05), but no significant change was observed in the MPF group (20.6° ± 2.5° to 20.4° ± 2.6°and 35.9 ± 5.1 to 34.1 ± 4.6 cm(2), respectively) (p > 0.05). Postoperative axial symptom severity was significantly worse in the CPF group than in the MPF group (Z = −2.357, p < 0.05). CONCLUSIONS: As an improvement to the conventional titanium plate, the modified centerpiece titanium plate effectively provides an attachment point for the posterior muscle–ligament complex, reducing posterior cervical muscle atrophy and improving neck function, without inflicting additional surgical trauma.
format Online
Article
Text
id pubmed-9837288
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher John Wiley & Sons Australia, Ltd
record_format MEDLINE/PubMed
spelling pubmed-98372882023-01-18 Novel Three‐Holed Titanium Plate Fixation during Open Door Laminoplasty for Cervical Spondylotic Myelopathy: Comparison with Conventional Titanium Plate Liu, Fa‐jing Liu, Yan‐cheng Hu, Yong‐cheng Ding, Xiao‐kun Miao, Jun Orthop Surg Clinical Articles OBJECTIVE: For reconstructing the posterior cervical muscular–ligament complex, attachment points and various modified techniques were designed and applied in clinical practice. This study investigated the clinical and radiographic outcomes of open door laminoplasty with modified centerpiece mini‐plate fixation and extensor attachment point reconstruction in the treatment of cervical spondylotic myelopathy (CSM). METHODS: Sixty‐nine patients with CSM who underwent C3–C7 open door laminoplasty at our hospital from January 2016 to May 2018 were divided into two groups: 37 and 32 patients underwent laminoplasty with modified and conventional centerpiece titanium plate fixation (MPF and CPF groups), respectively. Changes in cervical spinal angle (CSA), cervical range of motion (ROM), posterior cervical muscle atrophy, neurological function (Japanese Orthopaedic Association [JOA] score), Neck Disability Index (NDI), and axial symptom severity were compared between the two groups. RESULTS: There were no significant differences in operative duration (136.7 ± 23.9 vs 128.3 ± 21.5 min, t = 1.525, p > 0.05), volume of intraoperative blood loss (275.9 ± 33.1 vs 268.2 ± 31.6 ml, t = 0.984, p > 0.05), lamina open angle (41.2° ± 4.5° vs 39.4° ± 4.1°, t = 1.726, p > 0.05), and spinal cord drift distance (2.4 ± 0.3 vs 2.3 ± 0.4 mm, t = 1.184, p > 0.05) between the two groups. After surgery, JOA score significantly increased (p < 0.05), and neurological recovery rates were similar (62.7% vs 63.4%, t = 0.208, p > 0.05). The NDI score was significantly decreased in both the groups (p < 0.05); however, the MPF group recovered to a greater degree than the CPF group (8.3 ± 1.2 vs 9.8 ± 1.4) (t = 4.793, p < 0.05). There was no significant change in cervical ROM postoperatively compared with preoperatively in either group (p > 0.05). CSA decreased from 21.7° ± 2.8° to 18.3° ± 2.1°, and posterior cervical muscle cross‐sectional area decreased from 35.2 ± 4.9 cm(2) to 31.0 ± 4.1 cm(2) in the CPF group (p < 0.05), but no significant change was observed in the MPF group (20.6° ± 2.5° to 20.4° ± 2.6°and 35.9 ± 5.1 to 34.1 ± 4.6 cm(2), respectively) (p > 0.05). Postoperative axial symptom severity was significantly worse in the CPF group than in the MPF group (Z = −2.357, p < 0.05). CONCLUSIONS: As an improvement to the conventional titanium plate, the modified centerpiece titanium plate effectively provides an attachment point for the posterior muscle–ligament complex, reducing posterior cervical muscle atrophy and improving neck function, without inflicting additional surgical trauma. John Wiley & Sons Australia, Ltd 2022-11-23 /pmc/articles/PMC9837288/ /pubmed/36419321 http://dx.doi.org/10.1111/os.13551 Text en © 2022 The Authors. Orthopaedic Surgery published by Tianjin Hospital and John Wiley & Sons Australia, Ltd. https://creativecommons.org/licenses/by-nc/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
spellingShingle Clinical Articles
Liu, Fa‐jing
Liu, Yan‐cheng
Hu, Yong‐cheng
Ding, Xiao‐kun
Miao, Jun
Novel Three‐Holed Titanium Plate Fixation during Open Door Laminoplasty for Cervical Spondylotic Myelopathy: Comparison with Conventional Titanium Plate
title Novel Three‐Holed Titanium Plate Fixation during Open Door Laminoplasty for Cervical Spondylotic Myelopathy: Comparison with Conventional Titanium Plate
title_full Novel Three‐Holed Titanium Plate Fixation during Open Door Laminoplasty for Cervical Spondylotic Myelopathy: Comparison with Conventional Titanium Plate
title_fullStr Novel Three‐Holed Titanium Plate Fixation during Open Door Laminoplasty for Cervical Spondylotic Myelopathy: Comparison with Conventional Titanium Plate
title_full_unstemmed Novel Three‐Holed Titanium Plate Fixation during Open Door Laminoplasty for Cervical Spondylotic Myelopathy: Comparison with Conventional Titanium Plate
title_short Novel Three‐Holed Titanium Plate Fixation during Open Door Laminoplasty for Cervical Spondylotic Myelopathy: Comparison with Conventional Titanium Plate
title_sort novel three‐holed titanium plate fixation during open door laminoplasty for cervical spondylotic myelopathy: comparison with conventional titanium plate
topic Clinical Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9837288/
https://www.ncbi.nlm.nih.gov/pubmed/36419321
http://dx.doi.org/10.1111/os.13551
work_keys_str_mv AT liufajing novelthreeholedtitaniumplatefixationduringopendoorlaminoplastyforcervicalspondyloticmyelopathycomparisonwithconventionaltitaniumplate
AT liuyancheng novelthreeholedtitaniumplatefixationduringopendoorlaminoplastyforcervicalspondyloticmyelopathycomparisonwithconventionaltitaniumplate
AT huyongcheng novelthreeholedtitaniumplatefixationduringopendoorlaminoplastyforcervicalspondyloticmyelopathycomparisonwithconventionaltitaniumplate
AT dingxiaokun novelthreeholedtitaniumplatefixationduringopendoorlaminoplastyforcervicalspondyloticmyelopathycomparisonwithconventionaltitaniumplate
AT miaojun novelthreeholedtitaniumplatefixationduringopendoorlaminoplastyforcervicalspondyloticmyelopathycomparisonwithconventionaltitaniumplate