Cargando…

PneumoKITy: A fast, flexible, specific, and sensitive tool for Streptococcus pneumoniae serotype screening and mixed serotype detection from genome sequence data

Determination of serotypes of Streptococcus pneumoniae is essential for monitoring current vaccine programmes. Since October 2017, pneumococcal serotypes in England have been derived from whole genome sequencing (WGS) data using our bioinformatic tool PneumoCaT. That tool was designed for serotype d...

Descripción completa

Detalles Bibliográficos
Autores principales: Sheppard, Carmen L., Manna, Sam, Groves, Natalie, Litt, David J., Amin-Chowdhury, Zahin, Bertran, Marta, Ladhani, Shamez, Satzke, Catherine, Fry, Norman K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Microbiology Society 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9837567/
https://www.ncbi.nlm.nih.gov/pubmed/36748701
http://dx.doi.org/10.1099/mgen.0.000904
_version_ 1784869109464301568
author Sheppard, Carmen L.
Manna, Sam
Groves, Natalie
Litt, David J.
Amin-Chowdhury, Zahin
Bertran, Marta
Ladhani, Shamez
Satzke, Catherine
Fry, Norman K.
author_facet Sheppard, Carmen L.
Manna, Sam
Groves, Natalie
Litt, David J.
Amin-Chowdhury, Zahin
Bertran, Marta
Ladhani, Shamez
Satzke, Catherine
Fry, Norman K.
author_sort Sheppard, Carmen L.
collection PubMed
description Determination of serotypes of Streptococcus pneumoniae is essential for monitoring current vaccine programmes. Since October 2017, pneumococcal serotypes in England have been derived from whole genome sequencing (WGS) data using our bioinformatic tool PneumoCaT. That tool was designed for serotype determination from pure cultures in a reference laboratory. To help determine multiple serotypes in pneumococcal carriage samples, we developed a new software tool named PneumoKITy (Pneumococcal K-mer Integrated Typing) that uses the powerful Mash k-mer screening method for pneumococcal serotyping. Mash k-mer screening is more sequence specific and much faster than the mapping method used in PneumoCaT and can determine 54 (58.1  %) of the 93 serotypes in the SSI Diagnostica phenotypical serotyping scheme to type level with the remainder called to serogroup or subgroup level (e.g., 11A/D). PneumoKITy can be run on both FastQ and assembly input, requiring up to 11× less memory and running up to 29× faster than the current version of PneumoCaT (1.2.1) on FastQ files. PneumoKITy can be used as a rapid, flexible serotype screening method which adds sensitive detection of mixed serotypes, e.g., for nasopharyngeal carriage studies where the presence of multiple serotypes is common. PneumoKITy’s ability to function from assembly file, for pure culture serotype detection, increases its speed. This speed potentially enables the software to be run using low infrastructure overhead via web-based platforms. PneumoKITy could be used as a fast initial screening method with other tools used for those serotypes that could not be fully determined to type level if necessary. PneumoKITy was found to be highly accurate and sensitive when run on a panel of FastQ files derived from mixed cultures with all serotypes in 47/51 (92.2  %) of samples being accurately detected. PneumoKITy was also able to accurately estimate the relative abundance of serotypes in the same sample. Estimates being within a mean relative abundance of 1.5 % of the expected abundance in mixtures with known concentrations. PneumoKITy was able to detect minor serotypes with expected abundance of 1 % in the known mixture serotypes. PneumoKITy is a rapid, flexible tool with wide-ranging applications outside of the pure-culture, reference laboratory serotyping remit of PneumoCaT.
format Online
Article
Text
id pubmed-9837567
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Microbiology Society
record_format MEDLINE/PubMed
spelling pubmed-98375672023-01-13 PneumoKITy: A fast, flexible, specific, and sensitive tool for Streptococcus pneumoniae serotype screening and mixed serotype detection from genome sequence data Sheppard, Carmen L. Manna, Sam Groves, Natalie Litt, David J. Amin-Chowdhury, Zahin Bertran, Marta Ladhani, Shamez Satzke, Catherine Fry, Norman K. Microb Genom Research Articles Determination of serotypes of Streptococcus pneumoniae is essential for monitoring current vaccine programmes. Since October 2017, pneumococcal serotypes in England have been derived from whole genome sequencing (WGS) data using our bioinformatic tool PneumoCaT. That tool was designed for serotype determination from pure cultures in a reference laboratory. To help determine multiple serotypes in pneumococcal carriage samples, we developed a new software tool named PneumoKITy (Pneumococcal K-mer Integrated Typing) that uses the powerful Mash k-mer screening method for pneumococcal serotyping. Mash k-mer screening is more sequence specific and much faster than the mapping method used in PneumoCaT and can determine 54 (58.1  %) of the 93 serotypes in the SSI Diagnostica phenotypical serotyping scheme to type level with the remainder called to serogroup or subgroup level (e.g., 11A/D). PneumoKITy can be run on both FastQ and assembly input, requiring up to 11× less memory and running up to 29× faster than the current version of PneumoCaT (1.2.1) on FastQ files. PneumoKITy can be used as a rapid, flexible serotype screening method which adds sensitive detection of mixed serotypes, e.g., for nasopharyngeal carriage studies where the presence of multiple serotypes is common. PneumoKITy’s ability to function from assembly file, for pure culture serotype detection, increases its speed. This speed potentially enables the software to be run using low infrastructure overhead via web-based platforms. PneumoKITy could be used as a fast initial screening method with other tools used for those serotypes that could not be fully determined to type level if necessary. PneumoKITy was found to be highly accurate and sensitive when run on a panel of FastQ files derived from mixed cultures with all serotypes in 47/51 (92.2  %) of samples being accurately detected. PneumoKITy was also able to accurately estimate the relative abundance of serotypes in the same sample. Estimates being within a mean relative abundance of 1.5 % of the expected abundance in mixtures with known concentrations. PneumoKITy was able to detect minor serotypes with expected abundance of 1 % in the known mixture serotypes. PneumoKITy is a rapid, flexible tool with wide-ranging applications outside of the pure-culture, reference laboratory serotyping remit of PneumoCaT. Microbiology Society 2022-12-14 /pmc/articles/PMC9837567/ /pubmed/36748701 http://dx.doi.org/10.1099/mgen.0.000904 Text en © 2022 Crown copyright https://creativecommons.org/licenses/by/4.0/This information is licensed under the Open Government Licence 3.0. This is an open-access article distributed under the terms of the Creative Commons Attribution License. This article was made open access via a Publish and Read agreement between the Microbiology Society and the corresponding author’s institution.
spellingShingle Research Articles
Sheppard, Carmen L.
Manna, Sam
Groves, Natalie
Litt, David J.
Amin-Chowdhury, Zahin
Bertran, Marta
Ladhani, Shamez
Satzke, Catherine
Fry, Norman K.
PneumoKITy: A fast, flexible, specific, and sensitive tool for Streptococcus pneumoniae serotype screening and mixed serotype detection from genome sequence data
title PneumoKITy: A fast, flexible, specific, and sensitive tool for Streptococcus pneumoniae serotype screening and mixed serotype detection from genome sequence data
title_full PneumoKITy: A fast, flexible, specific, and sensitive tool for Streptococcus pneumoniae serotype screening and mixed serotype detection from genome sequence data
title_fullStr PneumoKITy: A fast, flexible, specific, and sensitive tool for Streptococcus pneumoniae serotype screening and mixed serotype detection from genome sequence data
title_full_unstemmed PneumoKITy: A fast, flexible, specific, and sensitive tool for Streptococcus pneumoniae serotype screening and mixed serotype detection from genome sequence data
title_short PneumoKITy: A fast, flexible, specific, and sensitive tool for Streptococcus pneumoniae serotype screening and mixed serotype detection from genome sequence data
title_sort pneumokity: a fast, flexible, specific, and sensitive tool for streptococcus pneumoniae serotype screening and mixed serotype detection from genome sequence data
topic Research Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9837567/
https://www.ncbi.nlm.nih.gov/pubmed/36748701
http://dx.doi.org/10.1099/mgen.0.000904
work_keys_str_mv AT sheppardcarmenl pneumokityafastflexiblespecificandsensitivetoolforstreptococcuspneumoniaeserotypescreeningandmixedserotypedetectionfromgenomesequencedata
AT mannasam pneumokityafastflexiblespecificandsensitivetoolforstreptococcuspneumoniaeserotypescreeningandmixedserotypedetectionfromgenomesequencedata
AT grovesnatalie pneumokityafastflexiblespecificandsensitivetoolforstreptococcuspneumoniaeserotypescreeningandmixedserotypedetectionfromgenomesequencedata
AT littdavidj pneumokityafastflexiblespecificandsensitivetoolforstreptococcuspneumoniaeserotypescreeningandmixedserotypedetectionfromgenomesequencedata
AT aminchowdhuryzahin pneumokityafastflexiblespecificandsensitivetoolforstreptococcuspneumoniaeserotypescreeningandmixedserotypedetectionfromgenomesequencedata
AT bertranmarta pneumokityafastflexiblespecificandsensitivetoolforstreptococcuspneumoniaeserotypescreeningandmixedserotypedetectionfromgenomesequencedata
AT ladhanishamez pneumokityafastflexiblespecificandsensitivetoolforstreptococcuspneumoniaeserotypescreeningandmixedserotypedetectionfromgenomesequencedata
AT satzkecatherine pneumokityafastflexiblespecificandsensitivetoolforstreptococcuspneumoniaeserotypescreeningandmixedserotypedetectionfromgenomesequencedata
AT frynormank pneumokityafastflexiblespecificandsensitivetoolforstreptococcuspneumoniaeserotypescreeningandmixedserotypedetectionfromgenomesequencedata