Cargando…
A feasibility study of reduced full-of-view synthetic high-b-value diffusion-weighted imaging in uterine tumors
OBJECTIVES: This study aimed to evaluate the feasibility of reduced full-of-view synthetic high-b value diffusion-weighted images (rFOV-syDWIs) in the clinical application of cervical cancer based on image quality and diagnostic efficacy. METHODS: We retrospectively evaluated the data of 35 patients...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Vienna
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9842823/ https://www.ncbi.nlm.nih.gov/pubmed/36645541 http://dx.doi.org/10.1186/s13244-022-01350-0 |
_version_ | 1784870232557355008 |
---|---|
author | Tang, Qian Zhou, Qiqi Chen, Wen Sang, Ling Xing, Yu Liu, Chao Wang, Kejun Liu, Weiyin Vivian Xu, Lin |
author_facet | Tang, Qian Zhou, Qiqi Chen, Wen Sang, Ling Xing, Yu Liu, Chao Wang, Kejun Liu, Weiyin Vivian Xu, Lin |
author_sort | Tang, Qian |
collection | PubMed |
description | OBJECTIVES: This study aimed to evaluate the feasibility of reduced full-of-view synthetic high-b value diffusion-weighted images (rFOV-syDWIs) in the clinical application of cervical cancer based on image quality and diagnostic efficacy. METHODS: We retrospectively evaluated the data of 35 patients with cervical cancer and 35 healthy volunteers from May to November 2021. All patients and volunteers underwent rFOV-DWI scans, including a 13b-protocol: b = 0, 25, 50, 75, 100, 150, 200, 400, 600, 800, 1000, 1200, and 1500 s/mm(2) and a 5b-protocol: b = 0, 100, 400, 800,1500 s/mm(2). rFOV-syDWIs with b values of 1200 (rFOV-syDWI(b=1200)) and 1500 (rFOV-syDWI(b=1500)) were generated from two different multiple-b-value image datasets using a mono-exponential fitting algorithm. According to homoscedasticity and normality assessed by the Levene’s test and Shapiro–Wilk test, the inter-modality differences of quantitative measurements were, respectively, examined by Wilcoxon signed-rank test or paired t test and the inter-group differences of ADC values were examined by independent t test or Mann–Whitney U test. RESULTS: A higher inter-reader agreement between SNRs and CNRs was found in 13b-protocol and 5b-protocol rFOV-syDWI(b=1200/1500) compared to 13b-protocol rFOV-sDWI(b=1200/1500) (p < 0.05). AUC of 5b-protocol syADC(mean,b=1200/1500) and syADC(minimum,b=1200/1500) was equal or higher than that of 13b-protocol sADC(mean,b=1200/1500) and sADC(minimum,b=1200/1500). CONCLUSIONS: rFOV-syDWIs provide better lesion clarity and higher image quality than rFOV-sDWIs. 5b-protocol rFOV-syDWIs shorten scan time, and synthetic ADCs offer reliable diagnosis value as scanned 13b-protocol DWIs. |
format | Online Article Text |
id | pubmed-9842823 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Springer Vienna |
record_format | MEDLINE/PubMed |
spelling | pubmed-98428232023-01-18 A feasibility study of reduced full-of-view synthetic high-b-value diffusion-weighted imaging in uterine tumors Tang, Qian Zhou, Qiqi Chen, Wen Sang, Ling Xing, Yu Liu, Chao Wang, Kejun Liu, Weiyin Vivian Xu, Lin Insights Imaging Original Article OBJECTIVES: This study aimed to evaluate the feasibility of reduced full-of-view synthetic high-b value diffusion-weighted images (rFOV-syDWIs) in the clinical application of cervical cancer based on image quality and diagnostic efficacy. METHODS: We retrospectively evaluated the data of 35 patients with cervical cancer and 35 healthy volunteers from May to November 2021. All patients and volunteers underwent rFOV-DWI scans, including a 13b-protocol: b = 0, 25, 50, 75, 100, 150, 200, 400, 600, 800, 1000, 1200, and 1500 s/mm(2) and a 5b-protocol: b = 0, 100, 400, 800,1500 s/mm(2). rFOV-syDWIs with b values of 1200 (rFOV-syDWI(b=1200)) and 1500 (rFOV-syDWI(b=1500)) were generated from two different multiple-b-value image datasets using a mono-exponential fitting algorithm. According to homoscedasticity and normality assessed by the Levene’s test and Shapiro–Wilk test, the inter-modality differences of quantitative measurements were, respectively, examined by Wilcoxon signed-rank test or paired t test and the inter-group differences of ADC values were examined by independent t test or Mann–Whitney U test. RESULTS: A higher inter-reader agreement between SNRs and CNRs was found in 13b-protocol and 5b-protocol rFOV-syDWI(b=1200/1500) compared to 13b-protocol rFOV-sDWI(b=1200/1500) (p < 0.05). AUC of 5b-protocol syADC(mean,b=1200/1500) and syADC(minimum,b=1200/1500) was equal or higher than that of 13b-protocol sADC(mean,b=1200/1500) and sADC(minimum,b=1200/1500). CONCLUSIONS: rFOV-syDWIs provide better lesion clarity and higher image quality than rFOV-sDWIs. 5b-protocol rFOV-syDWIs shorten scan time, and synthetic ADCs offer reliable diagnosis value as scanned 13b-protocol DWIs. Springer Vienna 2023-01-16 /pmc/articles/PMC9842823/ /pubmed/36645541 http://dx.doi.org/10.1186/s13244-022-01350-0 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Original Article Tang, Qian Zhou, Qiqi Chen, Wen Sang, Ling Xing, Yu Liu, Chao Wang, Kejun Liu, Weiyin Vivian Xu, Lin A feasibility study of reduced full-of-view synthetic high-b-value diffusion-weighted imaging in uterine tumors |
title | A feasibility study of reduced full-of-view synthetic high-b-value diffusion-weighted imaging in uterine tumors |
title_full | A feasibility study of reduced full-of-view synthetic high-b-value diffusion-weighted imaging in uterine tumors |
title_fullStr | A feasibility study of reduced full-of-view synthetic high-b-value diffusion-weighted imaging in uterine tumors |
title_full_unstemmed | A feasibility study of reduced full-of-view synthetic high-b-value diffusion-weighted imaging in uterine tumors |
title_short | A feasibility study of reduced full-of-view synthetic high-b-value diffusion-weighted imaging in uterine tumors |
title_sort | feasibility study of reduced full-of-view synthetic high-b-value diffusion-weighted imaging in uterine tumors |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9842823/ https://www.ncbi.nlm.nih.gov/pubmed/36645541 http://dx.doi.org/10.1186/s13244-022-01350-0 |
work_keys_str_mv | AT tangqian afeasibilitystudyofreducedfullofviewsynthetichighbvaluediffusionweightedimaginginuterinetumors AT zhouqiqi afeasibilitystudyofreducedfullofviewsynthetichighbvaluediffusionweightedimaginginuterinetumors AT chenwen afeasibilitystudyofreducedfullofviewsynthetichighbvaluediffusionweightedimaginginuterinetumors AT sangling afeasibilitystudyofreducedfullofviewsynthetichighbvaluediffusionweightedimaginginuterinetumors AT xingyu afeasibilitystudyofreducedfullofviewsynthetichighbvaluediffusionweightedimaginginuterinetumors AT liuchao afeasibilitystudyofreducedfullofviewsynthetichighbvaluediffusionweightedimaginginuterinetumors AT wangkejun afeasibilitystudyofreducedfullofviewsynthetichighbvaluediffusionweightedimaginginuterinetumors AT liuweiyinvivian afeasibilitystudyofreducedfullofviewsynthetichighbvaluediffusionweightedimaginginuterinetumors AT xulin afeasibilitystudyofreducedfullofviewsynthetichighbvaluediffusionweightedimaginginuterinetumors AT tangqian feasibilitystudyofreducedfullofviewsynthetichighbvaluediffusionweightedimaginginuterinetumors AT zhouqiqi feasibilitystudyofreducedfullofviewsynthetichighbvaluediffusionweightedimaginginuterinetumors AT chenwen feasibilitystudyofreducedfullofviewsynthetichighbvaluediffusionweightedimaginginuterinetumors AT sangling feasibilitystudyofreducedfullofviewsynthetichighbvaluediffusionweightedimaginginuterinetumors AT xingyu feasibilitystudyofreducedfullofviewsynthetichighbvaluediffusionweightedimaginginuterinetumors AT liuchao feasibilitystudyofreducedfullofviewsynthetichighbvaluediffusionweightedimaginginuterinetumors AT wangkejun feasibilitystudyofreducedfullofviewsynthetichighbvaluediffusionweightedimaginginuterinetumors AT liuweiyinvivian feasibilitystudyofreducedfullofviewsynthetichighbvaluediffusionweightedimaginginuterinetumors AT xulin feasibilitystudyofreducedfullofviewsynthetichighbvaluediffusionweightedimaginginuterinetumors |