Cargando…

A feasibility study of reduced full-of-view synthetic high-b-value diffusion-weighted imaging in uterine tumors

OBJECTIVES: This study aimed to evaluate the feasibility of reduced full-of-view synthetic high-b value diffusion-weighted images (rFOV-syDWIs) in the clinical application of cervical cancer based on image quality and diagnostic efficacy. METHODS: We retrospectively evaluated the data of 35 patients...

Descripción completa

Detalles Bibliográficos
Autores principales: Tang, Qian, Zhou, Qiqi, Chen, Wen, Sang, Ling, Xing, Yu, Liu, Chao, Wang, Kejun, Liu, Weiyin Vivian, Xu, Lin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Vienna 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9842823/
https://www.ncbi.nlm.nih.gov/pubmed/36645541
http://dx.doi.org/10.1186/s13244-022-01350-0
_version_ 1784870232557355008
author Tang, Qian
Zhou, Qiqi
Chen, Wen
Sang, Ling
Xing, Yu
Liu, Chao
Wang, Kejun
Liu, Weiyin Vivian
Xu, Lin
author_facet Tang, Qian
Zhou, Qiqi
Chen, Wen
Sang, Ling
Xing, Yu
Liu, Chao
Wang, Kejun
Liu, Weiyin Vivian
Xu, Lin
author_sort Tang, Qian
collection PubMed
description OBJECTIVES: This study aimed to evaluate the feasibility of reduced full-of-view synthetic high-b value diffusion-weighted images (rFOV-syDWIs) in the clinical application of cervical cancer based on image quality and diagnostic efficacy. METHODS: We retrospectively evaluated the data of 35 patients with cervical cancer and 35 healthy volunteers from May to November 2021. All patients and volunteers underwent rFOV-DWI scans, including a 13b-protocol: b = 0, 25, 50, 75, 100, 150, 200, 400, 600, 800, 1000, 1200, and 1500 s/mm(2) and a 5b-protocol: b = 0, 100, 400, 800,1500 s/mm(2). rFOV-syDWIs with b values of 1200 (rFOV-syDWI(b=1200)) and 1500 (rFOV-syDWI(b=1500)) were generated from two different multiple-b-value image datasets using a mono-exponential fitting algorithm. According to homoscedasticity and normality assessed by the Levene’s test and Shapiro–Wilk test, the inter-modality differences of quantitative measurements were, respectively, examined by Wilcoxon signed-rank test or paired t test and the inter-group differences of ADC values were examined by independent t test or Mann–Whitney U test. RESULTS: A higher inter-reader agreement between SNRs and CNRs was found in 13b-protocol and 5b-protocol rFOV-syDWI(b=1200/1500) compared to 13b-protocol rFOV-sDWI(b=1200/1500) (p < 0.05). AUC of 5b-protocol syADC(mean,b=1200/1500) and syADC(minimum,b=1200/1500) was equal or higher than that of 13b-protocol sADC(mean,b=1200/1500) and sADC(minimum,b=1200/1500). CONCLUSIONS: rFOV-syDWIs provide better lesion clarity and higher image quality than rFOV-sDWIs. 5b-protocol rFOV-syDWIs shorten scan time, and synthetic ADCs offer reliable diagnosis value as scanned 13b-protocol DWIs.
format Online
Article
Text
id pubmed-9842823
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Springer Vienna
record_format MEDLINE/PubMed
spelling pubmed-98428232023-01-18 A feasibility study of reduced full-of-view synthetic high-b-value diffusion-weighted imaging in uterine tumors Tang, Qian Zhou, Qiqi Chen, Wen Sang, Ling Xing, Yu Liu, Chao Wang, Kejun Liu, Weiyin Vivian Xu, Lin Insights Imaging Original Article OBJECTIVES: This study aimed to evaluate the feasibility of reduced full-of-view synthetic high-b value diffusion-weighted images (rFOV-syDWIs) in the clinical application of cervical cancer based on image quality and diagnostic efficacy. METHODS: We retrospectively evaluated the data of 35 patients with cervical cancer and 35 healthy volunteers from May to November 2021. All patients and volunteers underwent rFOV-DWI scans, including a 13b-protocol: b = 0, 25, 50, 75, 100, 150, 200, 400, 600, 800, 1000, 1200, and 1500 s/mm(2) and a 5b-protocol: b = 0, 100, 400, 800,1500 s/mm(2). rFOV-syDWIs with b values of 1200 (rFOV-syDWI(b=1200)) and 1500 (rFOV-syDWI(b=1500)) were generated from two different multiple-b-value image datasets using a mono-exponential fitting algorithm. According to homoscedasticity and normality assessed by the Levene’s test and Shapiro–Wilk test, the inter-modality differences of quantitative measurements were, respectively, examined by Wilcoxon signed-rank test or paired t test and the inter-group differences of ADC values were examined by independent t test or Mann–Whitney U test. RESULTS: A higher inter-reader agreement between SNRs and CNRs was found in 13b-protocol and 5b-protocol rFOV-syDWI(b=1200/1500) compared to 13b-protocol rFOV-sDWI(b=1200/1500) (p < 0.05). AUC of 5b-protocol syADC(mean,b=1200/1500) and syADC(minimum,b=1200/1500) was equal or higher than that of 13b-protocol sADC(mean,b=1200/1500) and sADC(minimum,b=1200/1500). CONCLUSIONS: rFOV-syDWIs provide better lesion clarity and higher image quality than rFOV-sDWIs. 5b-protocol rFOV-syDWIs shorten scan time, and synthetic ADCs offer reliable diagnosis value as scanned 13b-protocol DWIs. Springer Vienna 2023-01-16 /pmc/articles/PMC9842823/ /pubmed/36645541 http://dx.doi.org/10.1186/s13244-022-01350-0 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Article
Tang, Qian
Zhou, Qiqi
Chen, Wen
Sang, Ling
Xing, Yu
Liu, Chao
Wang, Kejun
Liu, Weiyin Vivian
Xu, Lin
A feasibility study of reduced full-of-view synthetic high-b-value diffusion-weighted imaging in uterine tumors
title A feasibility study of reduced full-of-view synthetic high-b-value diffusion-weighted imaging in uterine tumors
title_full A feasibility study of reduced full-of-view synthetic high-b-value diffusion-weighted imaging in uterine tumors
title_fullStr A feasibility study of reduced full-of-view synthetic high-b-value diffusion-weighted imaging in uterine tumors
title_full_unstemmed A feasibility study of reduced full-of-view synthetic high-b-value diffusion-weighted imaging in uterine tumors
title_short A feasibility study of reduced full-of-view synthetic high-b-value diffusion-weighted imaging in uterine tumors
title_sort feasibility study of reduced full-of-view synthetic high-b-value diffusion-weighted imaging in uterine tumors
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9842823/
https://www.ncbi.nlm.nih.gov/pubmed/36645541
http://dx.doi.org/10.1186/s13244-022-01350-0
work_keys_str_mv AT tangqian afeasibilitystudyofreducedfullofviewsynthetichighbvaluediffusionweightedimaginginuterinetumors
AT zhouqiqi afeasibilitystudyofreducedfullofviewsynthetichighbvaluediffusionweightedimaginginuterinetumors
AT chenwen afeasibilitystudyofreducedfullofviewsynthetichighbvaluediffusionweightedimaginginuterinetumors
AT sangling afeasibilitystudyofreducedfullofviewsynthetichighbvaluediffusionweightedimaginginuterinetumors
AT xingyu afeasibilitystudyofreducedfullofviewsynthetichighbvaluediffusionweightedimaginginuterinetumors
AT liuchao afeasibilitystudyofreducedfullofviewsynthetichighbvaluediffusionweightedimaginginuterinetumors
AT wangkejun afeasibilitystudyofreducedfullofviewsynthetichighbvaluediffusionweightedimaginginuterinetumors
AT liuweiyinvivian afeasibilitystudyofreducedfullofviewsynthetichighbvaluediffusionweightedimaginginuterinetumors
AT xulin afeasibilitystudyofreducedfullofviewsynthetichighbvaluediffusionweightedimaginginuterinetumors
AT tangqian feasibilitystudyofreducedfullofviewsynthetichighbvaluediffusionweightedimaginginuterinetumors
AT zhouqiqi feasibilitystudyofreducedfullofviewsynthetichighbvaluediffusionweightedimaginginuterinetumors
AT chenwen feasibilitystudyofreducedfullofviewsynthetichighbvaluediffusionweightedimaginginuterinetumors
AT sangling feasibilitystudyofreducedfullofviewsynthetichighbvaluediffusionweightedimaginginuterinetumors
AT xingyu feasibilitystudyofreducedfullofviewsynthetichighbvaluediffusionweightedimaginginuterinetumors
AT liuchao feasibilitystudyofreducedfullofviewsynthetichighbvaluediffusionweightedimaginginuterinetumors
AT wangkejun feasibilitystudyofreducedfullofviewsynthetichighbvaluediffusionweightedimaginginuterinetumors
AT liuweiyinvivian feasibilitystudyofreducedfullofviewsynthetichighbvaluediffusionweightedimaginginuterinetumors
AT xulin feasibilitystudyofreducedfullofviewsynthetichighbvaluediffusionweightedimaginginuterinetumors