Cargando…
Versatile electrical stimulator for cardiac tissue engineering—Investigation of charge-balanced monophasic and biphasic electrical stimulations
The application of biomimetic physical stimuli replicating the in vivo dynamic microenvironment is crucial for the in vitro development of functional cardiac tissues. In particular, pulsed electrical stimulation (ES) has been shown to improve the functional properties of in vitro cultured cardiomyoc...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9846083/ https://www.ncbi.nlm.nih.gov/pubmed/36686253 http://dx.doi.org/10.3389/fbioe.2022.1031183 |
_version_ | 1784871076471242752 |
---|---|
author | Gabetti, Stefano Sileo, Antonio Montrone, Federica Putame, Giovanni Audenino, Alberto L. Marsano, Anna Massai, Diana |
author_facet | Gabetti, Stefano Sileo, Antonio Montrone, Federica Putame, Giovanni Audenino, Alberto L. Marsano, Anna Massai, Diana |
author_sort | Gabetti, Stefano |
collection | PubMed |
description | The application of biomimetic physical stimuli replicating the in vivo dynamic microenvironment is crucial for the in vitro development of functional cardiac tissues. In particular, pulsed electrical stimulation (ES) has been shown to improve the functional properties of in vitro cultured cardiomyocytes. However, commercially available electrical stimulators are expensive and cumbersome devices while customized solutions often allow limited parameter tunability, constraining the investigation of different ES protocols. The goal of this study was to develop a versatile compact electrical stimulator (ELETTRA) for biomimetic cardiac tissue engineering approaches, designed for delivering controlled parallelizable ES at a competitive cost. ELETTRA is based on an open-source micro-controller running custom software and is combinable with different cell/tissue culture set-ups, allowing simultaneously testing different ES patterns on multiple samples. In particular, customized culture chambers were appositely designed and manufactured for investigating the influence of monophasic and biphasic pulsed ES on cardiac cell monolayers. Finite element analysis was performed for characterizing the spatial distributions of the electrical field and the current density within the culture chamber. Performance tests confirmed the accuracy, compliance, and reliability of the ES parameters delivered by ELETTRA. Biological tests were performed on neonatal rat cardiac cells, electrically stimulated for 4 days, by comparing, for the first time, the monophasic waveform (electric field = 5 V/cm) to biphasic waveforms by matching either the absolute value of the electric field variation (biphasic ES at ±2.5 V/cm) or the total delivered charge (biphasic ES at ±5 V/cm). Findings suggested that monophasic ES at 5 V/cm and, particularly, charge-balanced biphasic ES at ±5 V/cm were effective in enhancing electrical functionality of stimulated cardiac cells and in promoting synchronous contraction. |
format | Online Article Text |
id | pubmed-9846083 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-98460832023-01-19 Versatile electrical stimulator for cardiac tissue engineering—Investigation of charge-balanced monophasic and biphasic electrical stimulations Gabetti, Stefano Sileo, Antonio Montrone, Federica Putame, Giovanni Audenino, Alberto L. Marsano, Anna Massai, Diana Front Bioeng Biotechnol Bioengineering and Biotechnology The application of biomimetic physical stimuli replicating the in vivo dynamic microenvironment is crucial for the in vitro development of functional cardiac tissues. In particular, pulsed electrical stimulation (ES) has been shown to improve the functional properties of in vitro cultured cardiomyocytes. However, commercially available electrical stimulators are expensive and cumbersome devices while customized solutions often allow limited parameter tunability, constraining the investigation of different ES protocols. The goal of this study was to develop a versatile compact electrical stimulator (ELETTRA) for biomimetic cardiac tissue engineering approaches, designed for delivering controlled parallelizable ES at a competitive cost. ELETTRA is based on an open-source micro-controller running custom software and is combinable with different cell/tissue culture set-ups, allowing simultaneously testing different ES patterns on multiple samples. In particular, customized culture chambers were appositely designed and manufactured for investigating the influence of monophasic and biphasic pulsed ES on cardiac cell monolayers. Finite element analysis was performed for characterizing the spatial distributions of the electrical field and the current density within the culture chamber. Performance tests confirmed the accuracy, compliance, and reliability of the ES parameters delivered by ELETTRA. Biological tests were performed on neonatal rat cardiac cells, electrically stimulated for 4 days, by comparing, for the first time, the monophasic waveform (electric field = 5 V/cm) to biphasic waveforms by matching either the absolute value of the electric field variation (biphasic ES at ±2.5 V/cm) or the total delivered charge (biphasic ES at ±5 V/cm). Findings suggested that monophasic ES at 5 V/cm and, particularly, charge-balanced biphasic ES at ±5 V/cm were effective in enhancing electrical functionality of stimulated cardiac cells and in promoting synchronous contraction. Frontiers Media S.A. 2023-01-04 /pmc/articles/PMC9846083/ /pubmed/36686253 http://dx.doi.org/10.3389/fbioe.2022.1031183 Text en Copyright © 2023 Gabetti, Sileo, Montrone, Putame, Audenino, Marsano and Massai. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Bioengineering and Biotechnology Gabetti, Stefano Sileo, Antonio Montrone, Federica Putame, Giovanni Audenino, Alberto L. Marsano, Anna Massai, Diana Versatile electrical stimulator for cardiac tissue engineering—Investigation of charge-balanced monophasic and biphasic electrical stimulations |
title | Versatile electrical stimulator for cardiac tissue engineering—Investigation of charge-balanced monophasic and biphasic electrical stimulations |
title_full | Versatile electrical stimulator for cardiac tissue engineering—Investigation of charge-balanced monophasic and biphasic electrical stimulations |
title_fullStr | Versatile electrical stimulator for cardiac tissue engineering—Investigation of charge-balanced monophasic and biphasic electrical stimulations |
title_full_unstemmed | Versatile electrical stimulator for cardiac tissue engineering—Investigation of charge-balanced monophasic and biphasic electrical stimulations |
title_short | Versatile electrical stimulator for cardiac tissue engineering—Investigation of charge-balanced monophasic and biphasic electrical stimulations |
title_sort | versatile electrical stimulator for cardiac tissue engineering—investigation of charge-balanced monophasic and biphasic electrical stimulations |
topic | Bioengineering and Biotechnology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9846083/ https://www.ncbi.nlm.nih.gov/pubmed/36686253 http://dx.doi.org/10.3389/fbioe.2022.1031183 |
work_keys_str_mv | AT gabettistefano versatileelectricalstimulatorforcardiactissueengineeringinvestigationofchargebalancedmonophasicandbiphasicelectricalstimulations AT sileoantonio versatileelectricalstimulatorforcardiactissueengineeringinvestigationofchargebalancedmonophasicandbiphasicelectricalstimulations AT montronefederica versatileelectricalstimulatorforcardiactissueengineeringinvestigationofchargebalancedmonophasicandbiphasicelectricalstimulations AT putamegiovanni versatileelectricalstimulatorforcardiactissueengineeringinvestigationofchargebalancedmonophasicandbiphasicelectricalstimulations AT audeninoalbertol versatileelectricalstimulatorforcardiactissueengineeringinvestigationofchargebalancedmonophasicandbiphasicelectricalstimulations AT marsanoanna versatileelectricalstimulatorforcardiactissueengineeringinvestigationofchargebalancedmonophasicandbiphasicelectricalstimulations AT massaidiana versatileelectricalstimulatorforcardiactissueengineeringinvestigationofchargebalancedmonophasicandbiphasicelectricalstimulations |