Dose Agreement Analysis of Treatment Planning System-Calculated Doses and Markus Chamber-Measured Doses in the Near-Surface Region for Breast Cancer Patients' Conformal Treatment Plans
BACKGROUND: Surface/skin dose measurement is one of the most challenging tasks for clinical dosimetry in radiotherapy and comparison with almost all the commercially available treatment planning systems (TPSs) brings a significant variation with the measured dose. AIMS AND OBJECTIVES: In the current...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9847005/ https://www.ncbi.nlm.nih.gov/pubmed/36684697 http://dx.doi.org/10.4103/jmp.jmp_153_21 |
_version_ | 1784871333937545216 |
---|---|
author | Gaur, Garima Banipal, Raja Paramjeet Singh Garg, Pardeep Gurjar, Om Prakash Kaur, Gurpreet Sachdeva, Sheetal Grover, Romikant Kang, Manraj Singh Dangwal, Vinod Kumar |
author_facet | Gaur, Garima Banipal, Raja Paramjeet Singh Garg, Pardeep Gurjar, Om Prakash Kaur, Gurpreet Sachdeva, Sheetal Grover, Romikant Kang, Manraj Singh Dangwal, Vinod Kumar |
author_sort | Gaur, Garima |
collection | PubMed |
description | BACKGROUND: Surface/skin dose measurement is one of the most challenging tasks for clinical dosimetry in radiotherapy and comparison with almost all the commercially available treatment planning systems (TPSs) brings a significant variation with the measured dose. AIMS AND OBJECTIVES: In the current study, doses calculated from the TPS in the near-surface region for conformal plans (both three-dimensional conformal radiotherapy [3DCRT] and intensity-modulated radiotherapy [IMRT]) of 35 breast cancer patients were evaluated and compared with the doses measured with Markus chamber. MATERIALS AND METHODS: The computed tomography (CT) images of a solid water slab phantom with a Markus chamber (at different depths ranging from 1 mm to 5 mm from the surface) were taken and imported into the TPS. All the conformal treatment plans made in TPS were executed on a linear accelerator and dose agreements between TPS calculated and chamber measured doses were analysed. RESULTS: Results showed that this TPS underestimated the calculated doses in the superficial region by up to 26% and 21%, respectively, with respect to mean and maximum dose values obtained within the effective volume of the chamber used. CONCLUSION: The uncertainty of doses in the superficial region should be kept in mind when evaluating treatment plans for superficial tumours in TPS. |
format | Online Article Text |
id | pubmed-9847005 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-98470052023-01-19 Dose Agreement Analysis of Treatment Planning System-Calculated Doses and Markus Chamber-Measured Doses in the Near-Surface Region for Breast Cancer Patients' Conformal Treatment Plans Gaur, Garima Banipal, Raja Paramjeet Singh Garg, Pardeep Gurjar, Om Prakash Kaur, Gurpreet Sachdeva, Sheetal Grover, Romikant Kang, Manraj Singh Dangwal, Vinod Kumar J Med Phys Original Article BACKGROUND: Surface/skin dose measurement is one of the most challenging tasks for clinical dosimetry in radiotherapy and comparison with almost all the commercially available treatment planning systems (TPSs) brings a significant variation with the measured dose. AIMS AND OBJECTIVES: In the current study, doses calculated from the TPS in the near-surface region for conformal plans (both three-dimensional conformal radiotherapy [3DCRT] and intensity-modulated radiotherapy [IMRT]) of 35 breast cancer patients were evaluated and compared with the doses measured with Markus chamber. MATERIALS AND METHODS: The computed tomography (CT) images of a solid water slab phantom with a Markus chamber (at different depths ranging from 1 mm to 5 mm from the surface) were taken and imported into the TPS. All the conformal treatment plans made in TPS were executed on a linear accelerator and dose agreements between TPS calculated and chamber measured doses were analysed. RESULTS: Results showed that this TPS underestimated the calculated doses in the superficial region by up to 26% and 21%, respectively, with respect to mean and maximum dose values obtained within the effective volume of the chamber used. CONCLUSION: The uncertainty of doses in the superficial region should be kept in mind when evaluating treatment plans for superficial tumours in TPS. Wolters Kluwer - Medknow 2022 2022-11-08 /pmc/articles/PMC9847005/ /pubmed/36684697 http://dx.doi.org/10.4103/jmp.jmp_153_21 Text en Copyright: © 2022 Journal of Medical Physics https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Gaur, Garima Banipal, Raja Paramjeet Singh Garg, Pardeep Gurjar, Om Prakash Kaur, Gurpreet Sachdeva, Sheetal Grover, Romikant Kang, Manraj Singh Dangwal, Vinod Kumar Dose Agreement Analysis of Treatment Planning System-Calculated Doses and Markus Chamber-Measured Doses in the Near-Surface Region for Breast Cancer Patients' Conformal Treatment Plans |
title | Dose Agreement Analysis of Treatment Planning System-Calculated Doses and Markus Chamber-Measured Doses in the Near-Surface Region for Breast Cancer Patients' Conformal Treatment Plans |
title_full | Dose Agreement Analysis of Treatment Planning System-Calculated Doses and Markus Chamber-Measured Doses in the Near-Surface Region for Breast Cancer Patients' Conformal Treatment Plans |
title_fullStr | Dose Agreement Analysis of Treatment Planning System-Calculated Doses and Markus Chamber-Measured Doses in the Near-Surface Region for Breast Cancer Patients' Conformal Treatment Plans |
title_full_unstemmed | Dose Agreement Analysis of Treatment Planning System-Calculated Doses and Markus Chamber-Measured Doses in the Near-Surface Region for Breast Cancer Patients' Conformal Treatment Plans |
title_short | Dose Agreement Analysis of Treatment Planning System-Calculated Doses and Markus Chamber-Measured Doses in the Near-Surface Region for Breast Cancer Patients' Conformal Treatment Plans |
title_sort | dose agreement analysis of treatment planning system-calculated doses and markus chamber-measured doses in the near-surface region for breast cancer patients' conformal treatment plans |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9847005/ https://www.ncbi.nlm.nih.gov/pubmed/36684697 http://dx.doi.org/10.4103/jmp.jmp_153_21 |
work_keys_str_mv | AT gaurgarima doseagreementanalysisoftreatmentplanningsystemcalculateddosesandmarkuschambermeasureddosesinthenearsurfaceregionforbreastcancerpatientsconformaltreatmentplans AT banipalrajaparamjeetsingh doseagreementanalysisoftreatmentplanningsystemcalculateddosesandmarkuschambermeasureddosesinthenearsurfaceregionforbreastcancerpatientsconformaltreatmentplans AT gargpardeep doseagreementanalysisoftreatmentplanningsystemcalculateddosesandmarkuschambermeasureddosesinthenearsurfaceregionforbreastcancerpatientsconformaltreatmentplans AT gurjaromprakash doseagreementanalysisoftreatmentplanningsystemcalculateddosesandmarkuschambermeasureddosesinthenearsurfaceregionforbreastcancerpatientsconformaltreatmentplans AT kaurgurpreet doseagreementanalysisoftreatmentplanningsystemcalculateddosesandmarkuschambermeasureddosesinthenearsurfaceregionforbreastcancerpatientsconformaltreatmentplans AT sachdevasheetal doseagreementanalysisoftreatmentplanningsystemcalculateddosesandmarkuschambermeasureddosesinthenearsurfaceregionforbreastcancerpatientsconformaltreatmentplans AT groverromikant doseagreementanalysisoftreatmentplanningsystemcalculateddosesandmarkuschambermeasureddosesinthenearsurfaceregionforbreastcancerpatientsconformaltreatmentplans AT kangmanrajsingh doseagreementanalysisoftreatmentplanningsystemcalculateddosesandmarkuschambermeasureddosesinthenearsurfaceregionforbreastcancerpatientsconformaltreatmentplans AT dangwalvinodkumar doseagreementanalysisoftreatmentplanningsystemcalculateddosesandmarkuschambermeasureddosesinthenearsurfaceregionforbreastcancerpatientsconformaltreatmentplans |