Cargando…

A comparison of the changes in serum lactate between surgical repair and transthoracic device closure of ventricular septal defects in pediatric patients

OBJECTIVE: The purpose of this study was to compare the changes in serum lactate between surgical repair and transthoracic device closure of ventricular septal defects (VSDs) in pediatric patients. METHODS: This study was a retrospective analysis, and 314 pediatric patients with simple VSD from Octo...

Descripción completa

Detalles Bibliográficos
Autores principales: Huang, Jiang-Shan, Chen, Yu-Kun, Lin, Shi-Hao, Chen, Qiang, Cao, Hua, Zheng, Yi-Rong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9849590/
https://www.ncbi.nlm.nih.gov/pubmed/36684591
http://dx.doi.org/10.3389/fcvm.2022.961997
Descripción
Sumario:OBJECTIVE: The purpose of this study was to compare the changes in serum lactate between surgical repair and transthoracic device closure of ventricular septal defects (VSDs) in pediatric patients. METHODS: This study was a retrospective analysis, and 314 pediatric patients with simple VSD from October 2019 to October 2021 were selected. The patients were divided into the S group (surgical repair) and the D group (transthoracic device closure). The serum lactate value at ICU admission and 6 h after operation, as well as the highest serum lactate value were collected, and the 6-h serum lactate clearance rate was calculated. RESULT: Through propensity score matching, 43 pairs of cases were successfully matched. Compared with the S group, the D group had a shorter operation duration, ventilation duration, and ICU duration, as well as a lower drainage volume and total hospitalization cost. There was no significant difference between the two groups in the initial and highest serum lactate values after VSD closure, while the 6-h serum lactate value in the D group was significantly lower than that in the S group, and the 6-h serum lactate clearance rate in the D group was five times faster than that in the S group. In addition, the 6-h serum lactate clearance rate in the S group was mainly related to the operation time, CPB time, and ventilation time, while the 6-h serum lactate clearance rate in the D group was only related to the operation time. CONCLUSION: The initial and highest serum lactate levels were not significantly different between surgical repair and transthoracic device closure of VSD, but the 6-h serum lactate clearance rate of device closure was five times faster than that of surgical repair.