Cargando…
Volumetric modulated arc therapy based total marrow and lymphoid irradiation: Workflow and clinical experience
BACKGROUND: The aim of this study is to report historical treatment planning experience at our institution for patients receiving total marrow and lymphatic irradiation (TMLI) using volumetric modulated arc therapy (VMAT) as part of the conditioning regimen prior to hematopoietic stem cell transplan...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9849797/ https://www.ncbi.nlm.nih.gov/pubmed/36686805 http://dx.doi.org/10.3389/fonc.2022.1042652 |
_version_ | 1784872031207030784 |
---|---|
author | Ladbury, Colton Han, Chunhui Liu, An Wong, Jeffrey Y. C. |
author_facet | Ladbury, Colton Han, Chunhui Liu, An Wong, Jeffrey Y. C. |
author_sort | Ladbury, Colton |
collection | PubMed |
description | BACKGROUND: The aim of this study is to report historical treatment planning experience at our institution for patients receiving total marrow and lymphatic irradiation (TMLI) using volumetric modulated arc therapy (VMAT) as part of the conditioning regimen prior to hematopoietic stem cell transplant. METHODS: We identified a total of fifteen patients with VMAT TMLI, ten with a prescription dose of 20 Gy (targeting the skeletal bones, lymph nodes, spleen, and spinal canal, with 12 Gy to the brain and liver) and five with a prescription dose of 12-16 Gy (targeting the skeletal bones, lymph nodes, spleen, and spinal canal). Representative dosimetric parameters including total treatment time, mean and median dose, D80, and D10 (dose covering 80% and 10% of the structure volume, respectively) for targets and normal organs were extracted and compared to historical patients treated with helical tomotherapy. RESULTS: The median treatment time for the first and subsequent fractions was 1.5 and 1.1 hours, respectively. All the target volumes had a mean dose greater than the prescribed dose except the ribs, which had an average mean dose of 19.5 Gy. The skeletal bones had an average mean dose of 21.1 Gy. The brain and liver have average mean doses of 14.8 and 14.1 Gy, respectively. The mean lung dose had an average of 7.6 ± 0.6 Gy for the 20-Gy cohort. Relative to the prescription dose of 20 Gy, the average mean dose for the normal organ volumes ranged from 16.5% to 72.0%, and the average median dose for the normal organs ranged from 16.5% to 71.0%. Dosimetry for patients treated to 12-16 Gy fell within expected ranges based on historical helical tomotherapy plans. CONCLUSIONS: Dosimetric data in the VMAT TMLI plans at our institution are summarized for 20 Gy and 12-16 Gy cohorts. Dose distributions and treatment times are overall similar to plans generated with helical tomotherapy. TMLI may be delivered effectively using a VMAT technique, even at escalated doses. |
format | Online Article Text |
id | pubmed-9849797 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-98497972023-01-20 Volumetric modulated arc therapy based total marrow and lymphoid irradiation: Workflow and clinical experience Ladbury, Colton Han, Chunhui Liu, An Wong, Jeffrey Y. C. Front Oncol Oncology BACKGROUND: The aim of this study is to report historical treatment planning experience at our institution for patients receiving total marrow and lymphatic irradiation (TMLI) using volumetric modulated arc therapy (VMAT) as part of the conditioning regimen prior to hematopoietic stem cell transplant. METHODS: We identified a total of fifteen patients with VMAT TMLI, ten with a prescription dose of 20 Gy (targeting the skeletal bones, lymph nodes, spleen, and spinal canal, with 12 Gy to the brain and liver) and five with a prescription dose of 12-16 Gy (targeting the skeletal bones, lymph nodes, spleen, and spinal canal). Representative dosimetric parameters including total treatment time, mean and median dose, D80, and D10 (dose covering 80% and 10% of the structure volume, respectively) for targets and normal organs were extracted and compared to historical patients treated with helical tomotherapy. RESULTS: The median treatment time for the first and subsequent fractions was 1.5 and 1.1 hours, respectively. All the target volumes had a mean dose greater than the prescribed dose except the ribs, which had an average mean dose of 19.5 Gy. The skeletal bones had an average mean dose of 21.1 Gy. The brain and liver have average mean doses of 14.8 and 14.1 Gy, respectively. The mean lung dose had an average of 7.6 ± 0.6 Gy for the 20-Gy cohort. Relative to the prescription dose of 20 Gy, the average mean dose for the normal organ volumes ranged from 16.5% to 72.0%, and the average median dose for the normal organs ranged from 16.5% to 71.0%. Dosimetry for patients treated to 12-16 Gy fell within expected ranges based on historical helical tomotherapy plans. CONCLUSIONS: Dosimetric data in the VMAT TMLI plans at our institution are summarized for 20 Gy and 12-16 Gy cohorts. Dose distributions and treatment times are overall similar to plans generated with helical tomotherapy. TMLI may be delivered effectively using a VMAT technique, even at escalated doses. Frontiers Media S.A. 2023-01-05 /pmc/articles/PMC9849797/ /pubmed/36686805 http://dx.doi.org/10.3389/fonc.2022.1042652 Text en Copyright © 2023 Ladbury, Han, Liu and Wong https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Oncology Ladbury, Colton Han, Chunhui Liu, An Wong, Jeffrey Y. C. Volumetric modulated arc therapy based total marrow and lymphoid irradiation: Workflow and clinical experience |
title | Volumetric modulated arc therapy based total marrow and lymphoid irradiation: Workflow and clinical experience |
title_full | Volumetric modulated arc therapy based total marrow and lymphoid irradiation: Workflow and clinical experience |
title_fullStr | Volumetric modulated arc therapy based total marrow and lymphoid irradiation: Workflow and clinical experience |
title_full_unstemmed | Volumetric modulated arc therapy based total marrow and lymphoid irradiation: Workflow and clinical experience |
title_short | Volumetric modulated arc therapy based total marrow and lymphoid irradiation: Workflow and clinical experience |
title_sort | volumetric modulated arc therapy based total marrow and lymphoid irradiation: workflow and clinical experience |
topic | Oncology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9849797/ https://www.ncbi.nlm.nih.gov/pubmed/36686805 http://dx.doi.org/10.3389/fonc.2022.1042652 |
work_keys_str_mv | AT ladburycolton volumetricmodulatedarctherapybasedtotalmarrowandlymphoidirradiationworkflowandclinicalexperience AT hanchunhui volumetricmodulatedarctherapybasedtotalmarrowandlymphoidirradiationworkflowandclinicalexperience AT liuan volumetricmodulatedarctherapybasedtotalmarrowandlymphoidirradiationworkflowandclinicalexperience AT wongjeffreyyc volumetricmodulatedarctherapybasedtotalmarrowandlymphoidirradiationworkflowandclinicalexperience |