Cargando…

Performance of the bispectral index and electroencephalograph derived parameters of anesthetic depth during emergence from xenon and sevoflurane anesthesia

Many processed EEG monitors (pEEG) are unreliable when non-GABAergic anesthetic agents are used. The primary aim of the study was to compare the response of the Bispectral Index (BIS) during emergence from anesthesia maintained by xenon and sevoflurane. To better understand the variation in response...

Descripción completa

Detalles Bibliográficos
Autores principales: McGuigan, Steven, Scott, David A., Evered, Lisbeth, Silbert, Brendan, Liley, David T. J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Netherlands 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9852153/
https://www.ncbi.nlm.nih.gov/pubmed/35441313
http://dx.doi.org/10.1007/s10877-022-00860-y
_version_ 1784872549527584768
author McGuigan, Steven
Scott, David A.
Evered, Lisbeth
Silbert, Brendan
Liley, David T. J.
author_facet McGuigan, Steven
Scott, David A.
Evered, Lisbeth
Silbert, Brendan
Liley, David T. J.
author_sort McGuigan, Steven
collection PubMed
description Many processed EEG monitors (pEEG) are unreliable when non-GABAergic anesthetic agents are used. The primary aim of the study was to compare the response of the Bispectral Index (BIS) during emergence from anesthesia maintained by xenon and sevoflurane. To better understand the variation in response of pEEG to these agents, we also compared several EEG derived parameters relevant to pEEG monitoring during emergence. Twenty-four participants scheduled for lithotripsy were randomized to receive xenon or sevoflurane anesthesia. Participants were monitored with the BIS and had simultaneous raw EEG collected. BIS index values were compared at three key emergence timepoints: first response, eyes open and removal of airway. Two sets of EEG derived parameters, three related to the BIS: relative beta ratio, SynchFastSlow and SynchFastSlow biocoherence, and two unrelated to the BIS: spectral edge frequency and the composite cortical state, were calculated for comparison. BIS index values were significantly lower in the xenon group than the sevoflurane group at each emergence timepoint. The relative beta ratio parameter increased significantly during emergence in the sevoflurane group but not in the xenon group. The spectral edge frequency and composite cortical state parameters increased significantly in both groups during emergence. The BIS index is lower at equivalent stages of behavioural response during emergence from xenon anesthesia when compared to sevoflurane anesthesia, most likely due to differences in how these two agents influence the relative beta ratio. The spectral edge frequency and composite cortical state might better reflect emergence from xenon anaesthesia. Clinical trial number and registry Australia New Zealand Clinical Trials Registry Number: ACTRN12618000916246. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s10877-022-00860-y.
format Online
Article
Text
id pubmed-9852153
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Springer Netherlands
record_format MEDLINE/PubMed
spelling pubmed-98521532023-01-21 Performance of the bispectral index and electroencephalograph derived parameters of anesthetic depth during emergence from xenon and sevoflurane anesthesia McGuigan, Steven Scott, David A. Evered, Lisbeth Silbert, Brendan Liley, David T. J. J Clin Monit Comput Original Research Many processed EEG monitors (pEEG) are unreliable when non-GABAergic anesthetic agents are used. The primary aim of the study was to compare the response of the Bispectral Index (BIS) during emergence from anesthesia maintained by xenon and sevoflurane. To better understand the variation in response of pEEG to these agents, we also compared several EEG derived parameters relevant to pEEG monitoring during emergence. Twenty-four participants scheduled for lithotripsy were randomized to receive xenon or sevoflurane anesthesia. Participants were monitored with the BIS and had simultaneous raw EEG collected. BIS index values were compared at three key emergence timepoints: first response, eyes open and removal of airway. Two sets of EEG derived parameters, three related to the BIS: relative beta ratio, SynchFastSlow and SynchFastSlow biocoherence, and two unrelated to the BIS: spectral edge frequency and the composite cortical state, were calculated for comparison. BIS index values were significantly lower in the xenon group than the sevoflurane group at each emergence timepoint. The relative beta ratio parameter increased significantly during emergence in the sevoflurane group but not in the xenon group. The spectral edge frequency and composite cortical state parameters increased significantly in both groups during emergence. The BIS index is lower at equivalent stages of behavioural response during emergence from xenon anesthesia when compared to sevoflurane anesthesia, most likely due to differences in how these two agents influence the relative beta ratio. The spectral edge frequency and composite cortical state might better reflect emergence from xenon anaesthesia. Clinical trial number and registry Australia New Zealand Clinical Trials Registry Number: ACTRN12618000916246. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s10877-022-00860-y. Springer Netherlands 2022-04-19 2023 /pmc/articles/PMC9852153/ /pubmed/35441313 http://dx.doi.org/10.1007/s10877-022-00860-y Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Research
McGuigan, Steven
Scott, David A.
Evered, Lisbeth
Silbert, Brendan
Liley, David T. J.
Performance of the bispectral index and electroencephalograph derived parameters of anesthetic depth during emergence from xenon and sevoflurane anesthesia
title Performance of the bispectral index and electroencephalograph derived parameters of anesthetic depth during emergence from xenon and sevoflurane anesthesia
title_full Performance of the bispectral index and electroencephalograph derived parameters of anesthetic depth during emergence from xenon and sevoflurane anesthesia
title_fullStr Performance of the bispectral index and electroencephalograph derived parameters of anesthetic depth during emergence from xenon and sevoflurane anesthesia
title_full_unstemmed Performance of the bispectral index and electroencephalograph derived parameters of anesthetic depth during emergence from xenon and sevoflurane anesthesia
title_short Performance of the bispectral index and electroencephalograph derived parameters of anesthetic depth during emergence from xenon and sevoflurane anesthesia
title_sort performance of the bispectral index and electroencephalograph derived parameters of anesthetic depth during emergence from xenon and sevoflurane anesthesia
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9852153/
https://www.ncbi.nlm.nih.gov/pubmed/35441313
http://dx.doi.org/10.1007/s10877-022-00860-y
work_keys_str_mv AT mcguigansteven performanceofthebispectralindexandelectroencephalographderivedparametersofanestheticdepthduringemergencefromxenonandsevofluraneanesthesia
AT scottdavida performanceofthebispectralindexandelectroencephalographderivedparametersofanestheticdepthduringemergencefromxenonandsevofluraneanesthesia
AT everedlisbeth performanceofthebispectralindexandelectroencephalographderivedparametersofanestheticdepthduringemergencefromxenonandsevofluraneanesthesia
AT silbertbrendan performanceofthebispectralindexandelectroencephalographderivedparametersofanestheticdepthduringemergencefromxenonandsevofluraneanesthesia
AT lileydavidtj performanceofthebispectralindexandelectroencephalographderivedparametersofanestheticdepthduringemergencefromxenonandsevofluraneanesthesia