Cargando…
Combined [68 Ga]Ga-PSMA-11 and low-dose 2-[18F]FDG PET/CT using a long-axial field of view scanner for patients referred for [177Lu]-PSMA-radioligand therapy
PURPOSE: Performing 2-[(18)F]FDG PET/CT in addition to a PSMA-ligand PET/CT can assist in the detection of lesions with low PSMA expression and may help in prognostication and identification of patients who likely benefit from PSMA-radioligand therapy (PSMA-RLT). However, the cost and time needed fo...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9852199/ https://www.ncbi.nlm.nih.gov/pubmed/36136102 http://dx.doi.org/10.1007/s00259-022-05961-z |
_version_ | 1784872561999347712 |
---|---|
author | Alberts, Ian Schepers, Robin Zeimpekis, Konstantinos Sari, Hasan Rominger, Axel Afshar-Oromieh, Ali |
author_facet | Alberts, Ian Schepers, Robin Zeimpekis, Konstantinos Sari, Hasan Rominger, Axel Afshar-Oromieh, Ali |
author_sort | Alberts, Ian |
collection | PubMed |
description | PURPOSE: Performing 2-[(18)F]FDG PET/CT in addition to a PSMA-ligand PET/CT can assist in the detection of lesions with low PSMA expression and may help in prognostication and identification of patients who likely benefit from PSMA-radioligand therapy (PSMA-RLT). However, the cost and time needed for a separate PET/CT examination might hinder its routine implementation. In this communication, we present our initial experiences with additional low-dose 2-[(18)F]FDG PET/CT as part of a dual-tracer and same-day imaging protocol which exploits the higher sensitivity exhibited by long-axial field-of-view (LAFOV) and total-body PET/CT systems and demonstrates its feasibility. METHODS: Fourteen patients referred for evaluation for PSMA-RLT received [(68) Ga]Ga-PSMA-11 PET/CT at 1 h p.i. with a standard activity of 150 MBq and an additional low-dose 2-[(18)F]FDG PET/CT with 40 MBq 1 h thereafter using a long-axial field-of-view PET/CT system in a single sitting and as per institutional protocol. Scans were scrutinized by two experienced nuclear medicine physicians for mismatch findings. RESULTS: The combined protocol identified additional lesions with low or absent PSMA-expression but high FDG-avidity in 1/14 (7%) patients. The protocol was easily implemented and well tolerated by all patients. CONCLUSION: Additional low-dose 2-[(18)F]FDG-PET/CT is feasible as part of a same-day imaging protocol and can help reveal lesions of low PSMA avidity as part of therapy assessment for [(177)Lu]-PSMA radioligand therapy and demonstrates higher sensitivity compared to [(68) Ga]Ga-PSMA-11 PET/CT alone in some patients. |
format | Online Article Text |
id | pubmed-9852199 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-98521992023-01-21 Combined [68 Ga]Ga-PSMA-11 and low-dose 2-[18F]FDG PET/CT using a long-axial field of view scanner for patients referred for [177Lu]-PSMA-radioligand therapy Alberts, Ian Schepers, Robin Zeimpekis, Konstantinos Sari, Hasan Rominger, Axel Afshar-Oromieh, Ali Eur J Nucl Med Mol Imaging Short Communication PURPOSE: Performing 2-[(18)F]FDG PET/CT in addition to a PSMA-ligand PET/CT can assist in the detection of lesions with low PSMA expression and may help in prognostication and identification of patients who likely benefit from PSMA-radioligand therapy (PSMA-RLT). However, the cost and time needed for a separate PET/CT examination might hinder its routine implementation. In this communication, we present our initial experiences with additional low-dose 2-[(18)F]FDG PET/CT as part of a dual-tracer and same-day imaging protocol which exploits the higher sensitivity exhibited by long-axial field-of-view (LAFOV) and total-body PET/CT systems and demonstrates its feasibility. METHODS: Fourteen patients referred for evaluation for PSMA-RLT received [(68) Ga]Ga-PSMA-11 PET/CT at 1 h p.i. with a standard activity of 150 MBq and an additional low-dose 2-[(18)F]FDG PET/CT with 40 MBq 1 h thereafter using a long-axial field-of-view PET/CT system in a single sitting and as per institutional protocol. Scans were scrutinized by two experienced nuclear medicine physicians for mismatch findings. RESULTS: The combined protocol identified additional lesions with low or absent PSMA-expression but high FDG-avidity in 1/14 (7%) patients. The protocol was easily implemented and well tolerated by all patients. CONCLUSION: Additional low-dose 2-[(18)F]FDG-PET/CT is feasible as part of a same-day imaging protocol and can help reveal lesions of low PSMA avidity as part of therapy assessment for [(177)Lu]-PSMA radioligand therapy and demonstrates higher sensitivity compared to [(68) Ga]Ga-PSMA-11 PET/CT alone in some patients. Springer Berlin Heidelberg 2022-09-22 2023 /pmc/articles/PMC9852199/ /pubmed/36136102 http://dx.doi.org/10.1007/s00259-022-05961-z Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Short Communication Alberts, Ian Schepers, Robin Zeimpekis, Konstantinos Sari, Hasan Rominger, Axel Afshar-Oromieh, Ali Combined [68 Ga]Ga-PSMA-11 and low-dose 2-[18F]FDG PET/CT using a long-axial field of view scanner for patients referred for [177Lu]-PSMA-radioligand therapy |
title | Combined [68 Ga]Ga-PSMA-11 and low-dose 2-[18F]FDG PET/CT using a long-axial field of view scanner for patients referred for [177Lu]-PSMA-radioligand therapy |
title_full | Combined [68 Ga]Ga-PSMA-11 and low-dose 2-[18F]FDG PET/CT using a long-axial field of view scanner for patients referred for [177Lu]-PSMA-radioligand therapy |
title_fullStr | Combined [68 Ga]Ga-PSMA-11 and low-dose 2-[18F]FDG PET/CT using a long-axial field of view scanner for patients referred for [177Lu]-PSMA-radioligand therapy |
title_full_unstemmed | Combined [68 Ga]Ga-PSMA-11 and low-dose 2-[18F]FDG PET/CT using a long-axial field of view scanner for patients referred for [177Lu]-PSMA-radioligand therapy |
title_short | Combined [68 Ga]Ga-PSMA-11 and low-dose 2-[18F]FDG PET/CT using a long-axial field of view scanner for patients referred for [177Lu]-PSMA-radioligand therapy |
title_sort | combined [68 ga]ga-psma-11 and low-dose 2-[18f]fdg pet/ct using a long-axial field of view scanner for patients referred for [177lu]-psma-radioligand therapy |
topic | Short Communication |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9852199/ https://www.ncbi.nlm.nih.gov/pubmed/36136102 http://dx.doi.org/10.1007/s00259-022-05961-z |
work_keys_str_mv | AT albertsian combined68gagapsma11andlowdose218ffdgpetctusingalongaxialfieldofviewscannerforpatientsreferredfor177lupsmaradioligandtherapy AT schepersrobin combined68gagapsma11andlowdose218ffdgpetctusingalongaxialfieldofviewscannerforpatientsreferredfor177lupsmaradioligandtherapy AT zeimpekiskonstantinos combined68gagapsma11andlowdose218ffdgpetctusingalongaxialfieldofviewscannerforpatientsreferredfor177lupsmaradioligandtherapy AT sarihasan combined68gagapsma11andlowdose218ffdgpetctusingalongaxialfieldofviewscannerforpatientsreferredfor177lupsmaradioligandtherapy AT romingeraxel combined68gagapsma11andlowdose218ffdgpetctusingalongaxialfieldofviewscannerforpatientsreferredfor177lupsmaradioligandtherapy AT afsharoromiehali combined68gagapsma11andlowdose218ffdgpetctusingalongaxialfieldofviewscannerforpatientsreferredfor177lupsmaradioligandtherapy |