Case Report: Using Medtronic AP360 mechanical prosthesis in mitral valve replacement for patients with mitral insufficiency after primum atrial septal defect repair to reduce left ventricular outflow tract obstruction risk
BACKGROUND: Atrial septal defect is one of the most common congenital heart diseases in adults. Primum atrial septal defect (PASD) accounts for 4%–5% of congenital heart defects. Patients with PASD frequently suffer mitral insufficiency (MI), and thus, mitral valvuloplasty (MVP) or mitral valve repl...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9852323/ https://www.ncbi.nlm.nih.gov/pubmed/36684337 http://dx.doi.org/10.3389/fsurg.2022.1008444 |
_version_ | 1784872609391837184 |
---|---|
author | Guo, Lei Yang, Qiqi Han, Yu Zhao, Haige Chen, Liangwei Zheng, Junnan Ni, Yiming |
author_facet | Guo, Lei Yang, Qiqi Han, Yu Zhao, Haige Chen, Liangwei Zheng, Junnan Ni, Yiming |
author_sort | Guo, Lei |
collection | PubMed |
description | BACKGROUND: Atrial septal defect is one of the most common congenital heart diseases in adults. Primum atrial septal defect (PASD) accounts for 4%–5% of congenital heart defects. Patients with PASD frequently suffer mitral insufficiency (MI), and thus, mitral valvuloplasty (MVP) or mitral valve replacement (MVR) is often required at the time of PASD repair. Unfortunately, recurrent unrepairable severe mitral regurgitation can develop in many patients undergoing PASD repair plus MVP in either short- or long-term after the repair surgery, requiring a re-do MVR. In those patients, the risk of left ventricular outflow tract obstruction (LVOTO) has increased. CASE PRESENTATION: We present five such cases, ranging in age from 24 to 47 years, who had a PASD repair plus MVP or MVR for 14–40 years while suffering moderate to severe mitral regurgitation. Using Medtronic AP360 mechanical mitral prostheses, only one patient experienced mild LVOTO. CONCLUSIONS: The use of Medtronic AP360 mechanical mitral prostheses to perform MVR in patients with MI who had a history of PASD repair can potentially reduce the risk of LVOTO. Long-term follow-up is required to further confirm this clinical benefit associated with AP360 implantation in patients with PASD. |
format | Online Article Text |
id | pubmed-9852323 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-98523232023-01-21 Case Report: Using Medtronic AP360 mechanical prosthesis in mitral valve replacement for patients with mitral insufficiency after primum atrial septal defect repair to reduce left ventricular outflow tract obstruction risk Guo, Lei Yang, Qiqi Han, Yu Zhao, Haige Chen, Liangwei Zheng, Junnan Ni, Yiming Front Surg Surgery BACKGROUND: Atrial septal defect is one of the most common congenital heart diseases in adults. Primum atrial septal defect (PASD) accounts for 4%–5% of congenital heart defects. Patients with PASD frequently suffer mitral insufficiency (MI), and thus, mitral valvuloplasty (MVP) or mitral valve replacement (MVR) is often required at the time of PASD repair. Unfortunately, recurrent unrepairable severe mitral regurgitation can develop in many patients undergoing PASD repair plus MVP in either short- or long-term after the repair surgery, requiring a re-do MVR. In those patients, the risk of left ventricular outflow tract obstruction (LVOTO) has increased. CASE PRESENTATION: We present five such cases, ranging in age from 24 to 47 years, who had a PASD repair plus MVP or MVR for 14–40 years while suffering moderate to severe mitral regurgitation. Using Medtronic AP360 mechanical mitral prostheses, only one patient experienced mild LVOTO. CONCLUSIONS: The use of Medtronic AP360 mechanical mitral prostheses to perform MVR in patients with MI who had a history of PASD repair can potentially reduce the risk of LVOTO. Long-term follow-up is required to further confirm this clinical benefit associated with AP360 implantation in patients with PASD. Frontiers Media S.A. 2023-01-06 /pmc/articles/PMC9852323/ /pubmed/36684337 http://dx.doi.org/10.3389/fsurg.2022.1008444 Text en © 2023 Guo, Yang, Han, Zhao, Chen, Zheng and Ni. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY) (https://creativecommons.org/licenses/by/4.0/) . The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Surgery Guo, Lei Yang, Qiqi Han, Yu Zhao, Haige Chen, Liangwei Zheng, Junnan Ni, Yiming Case Report: Using Medtronic AP360 mechanical prosthesis in mitral valve replacement for patients with mitral insufficiency after primum atrial septal defect repair to reduce left ventricular outflow tract obstruction risk |
title | Case Report: Using Medtronic AP360 mechanical prosthesis in mitral valve replacement for patients with mitral insufficiency after primum atrial septal defect repair to reduce left ventricular outflow tract obstruction risk |
title_full | Case Report: Using Medtronic AP360 mechanical prosthesis in mitral valve replacement for patients with mitral insufficiency after primum atrial septal defect repair to reduce left ventricular outflow tract obstruction risk |
title_fullStr | Case Report: Using Medtronic AP360 mechanical prosthesis in mitral valve replacement for patients with mitral insufficiency after primum atrial septal defect repair to reduce left ventricular outflow tract obstruction risk |
title_full_unstemmed | Case Report: Using Medtronic AP360 mechanical prosthesis in mitral valve replacement for patients with mitral insufficiency after primum atrial septal defect repair to reduce left ventricular outflow tract obstruction risk |
title_short | Case Report: Using Medtronic AP360 mechanical prosthesis in mitral valve replacement for patients with mitral insufficiency after primum atrial septal defect repair to reduce left ventricular outflow tract obstruction risk |
title_sort | case report: using medtronic ap360 mechanical prosthesis in mitral valve replacement for patients with mitral insufficiency after primum atrial septal defect repair to reduce left ventricular outflow tract obstruction risk |
topic | Surgery |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9852323/ https://www.ncbi.nlm.nih.gov/pubmed/36684337 http://dx.doi.org/10.3389/fsurg.2022.1008444 |
work_keys_str_mv | AT guolei casereportusingmedtronicap360mechanicalprosthesisinmitralvalvereplacementforpatientswithmitralinsufficiencyafterprimumatrialseptaldefectrepairtoreduceleftventricularoutflowtractobstructionrisk AT yangqiqi casereportusingmedtronicap360mechanicalprosthesisinmitralvalvereplacementforpatientswithmitralinsufficiencyafterprimumatrialseptaldefectrepairtoreduceleftventricularoutflowtractobstructionrisk AT hanyu casereportusingmedtronicap360mechanicalprosthesisinmitralvalvereplacementforpatientswithmitralinsufficiencyafterprimumatrialseptaldefectrepairtoreduceleftventricularoutflowtractobstructionrisk AT zhaohaige casereportusingmedtronicap360mechanicalprosthesisinmitralvalvereplacementforpatientswithmitralinsufficiencyafterprimumatrialseptaldefectrepairtoreduceleftventricularoutflowtractobstructionrisk AT chenliangwei casereportusingmedtronicap360mechanicalprosthesisinmitralvalvereplacementforpatientswithmitralinsufficiencyafterprimumatrialseptaldefectrepairtoreduceleftventricularoutflowtractobstructionrisk AT zhengjunnan casereportusingmedtronicap360mechanicalprosthesisinmitralvalvereplacementforpatientswithmitralinsufficiencyafterprimumatrialseptaldefectrepairtoreduceleftventricularoutflowtractobstructionrisk AT niyiming casereportusingmedtronicap360mechanicalprosthesisinmitralvalvereplacementforpatientswithmitralinsufficiencyafterprimumatrialseptaldefectrepairtoreduceleftventricularoutflowtractobstructionrisk |