Cargando…

Mobility recorded by wearable devices and gold standards: the Mobilise-D procedure for data standardization

Wearable devices are used in movement analysis and physical activity research to extract clinically relevant information about an individual’s mobility. Still, heterogeneity in protocols, sensor characteristics, data formats, and gold standards represent a barrier for data sharing, reproducibility,...

Descripción completa

Detalles Bibliográficos
Autores principales: Palmerini, Luca, Reggi, Luca, Bonci, Tecla, Del Din, Silvia, Micó-Amigo, M. Encarna, Salis, Francesca, Bertuletti, Stefano, Caruso, Marco, Cereatti, Andrea, Gazit, Eran, Paraschiv-Ionescu, Anisoara, Soltani, Abolfazl, Kluge, Felix, Küderle, Arne, Ullrich, Martin, Kirk, Cameron, Hiden, Hugo, D’Ascanio, Ilaria, Hansen, Clint, Rochester, Lynn, Mazzà, Claudia, Chiari, Lorenzo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9852581/
https://www.ncbi.nlm.nih.gov/pubmed/36658136
http://dx.doi.org/10.1038/s41597-023-01930-9
_version_ 1784872677588074496
author Palmerini, Luca
Reggi, Luca
Bonci, Tecla
Del Din, Silvia
Micó-Amigo, M. Encarna
Salis, Francesca
Bertuletti, Stefano
Caruso, Marco
Cereatti, Andrea
Gazit, Eran
Paraschiv-Ionescu, Anisoara
Soltani, Abolfazl
Kluge, Felix
Küderle, Arne
Ullrich, Martin
Kirk, Cameron
Hiden, Hugo
D’Ascanio, Ilaria
Hansen, Clint
Rochester, Lynn
Mazzà, Claudia
Chiari, Lorenzo
author_facet Palmerini, Luca
Reggi, Luca
Bonci, Tecla
Del Din, Silvia
Micó-Amigo, M. Encarna
Salis, Francesca
Bertuletti, Stefano
Caruso, Marco
Cereatti, Andrea
Gazit, Eran
Paraschiv-Ionescu, Anisoara
Soltani, Abolfazl
Kluge, Felix
Küderle, Arne
Ullrich, Martin
Kirk, Cameron
Hiden, Hugo
D’Ascanio, Ilaria
Hansen, Clint
Rochester, Lynn
Mazzà, Claudia
Chiari, Lorenzo
author_sort Palmerini, Luca
collection PubMed
description Wearable devices are used in movement analysis and physical activity research to extract clinically relevant information about an individual’s mobility. Still, heterogeneity in protocols, sensor characteristics, data formats, and gold standards represent a barrier for data sharing, reproducibility, and external validation. In this study, we aim at providing an example of how movement data (from the real-world and the laboratory) recorded from different wearables and gold standard technologies can be organized, integrated, and stored. We leveraged on our experience from a large multi-centric study (Mobilise-D) to provide guidelines that can prove useful to access, understand, and re-use the data that will be made available from the study. These guidelines highlight the encountered challenges and the adopted solutions with the final aim of supporting standardization and integration of data in other studies and, in turn, to increase and facilitate comparison of data recorded in the scientific community. We also provide samples of standardized data, so that both the structure of the data and the procedure can be easily understood and reproduced.
format Online
Article
Text
id pubmed-9852581
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-98525812023-01-21 Mobility recorded by wearable devices and gold standards: the Mobilise-D procedure for data standardization Palmerini, Luca Reggi, Luca Bonci, Tecla Del Din, Silvia Micó-Amigo, M. Encarna Salis, Francesca Bertuletti, Stefano Caruso, Marco Cereatti, Andrea Gazit, Eran Paraschiv-Ionescu, Anisoara Soltani, Abolfazl Kluge, Felix Küderle, Arne Ullrich, Martin Kirk, Cameron Hiden, Hugo D’Ascanio, Ilaria Hansen, Clint Rochester, Lynn Mazzà, Claudia Chiari, Lorenzo Sci Data Article Wearable devices are used in movement analysis and physical activity research to extract clinically relevant information about an individual’s mobility. Still, heterogeneity in protocols, sensor characteristics, data formats, and gold standards represent a barrier for data sharing, reproducibility, and external validation. In this study, we aim at providing an example of how movement data (from the real-world and the laboratory) recorded from different wearables and gold standard technologies can be organized, integrated, and stored. We leveraged on our experience from a large multi-centric study (Mobilise-D) to provide guidelines that can prove useful to access, understand, and re-use the data that will be made available from the study. These guidelines highlight the encountered challenges and the adopted solutions with the final aim of supporting standardization and integration of data in other studies and, in turn, to increase and facilitate comparison of data recorded in the scientific community. We also provide samples of standardized data, so that both the structure of the data and the procedure can be easily understood and reproduced. Nature Publishing Group UK 2023-01-19 /pmc/articles/PMC9852581/ /pubmed/36658136 http://dx.doi.org/10.1038/s41597-023-01930-9 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Palmerini, Luca
Reggi, Luca
Bonci, Tecla
Del Din, Silvia
Micó-Amigo, M. Encarna
Salis, Francesca
Bertuletti, Stefano
Caruso, Marco
Cereatti, Andrea
Gazit, Eran
Paraschiv-Ionescu, Anisoara
Soltani, Abolfazl
Kluge, Felix
Küderle, Arne
Ullrich, Martin
Kirk, Cameron
Hiden, Hugo
D’Ascanio, Ilaria
Hansen, Clint
Rochester, Lynn
Mazzà, Claudia
Chiari, Lorenzo
Mobility recorded by wearable devices and gold standards: the Mobilise-D procedure for data standardization
title Mobility recorded by wearable devices and gold standards: the Mobilise-D procedure for data standardization
title_full Mobility recorded by wearable devices and gold standards: the Mobilise-D procedure for data standardization
title_fullStr Mobility recorded by wearable devices and gold standards: the Mobilise-D procedure for data standardization
title_full_unstemmed Mobility recorded by wearable devices and gold standards: the Mobilise-D procedure for data standardization
title_short Mobility recorded by wearable devices and gold standards: the Mobilise-D procedure for data standardization
title_sort mobility recorded by wearable devices and gold standards: the mobilise-d procedure for data standardization
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9852581/
https://www.ncbi.nlm.nih.gov/pubmed/36658136
http://dx.doi.org/10.1038/s41597-023-01930-9
work_keys_str_mv AT palmeriniluca mobilityrecordedbywearabledevicesandgoldstandardsthemobilisedprocedurefordatastandardization
AT reggiluca mobilityrecordedbywearabledevicesandgoldstandardsthemobilisedprocedurefordatastandardization
AT boncitecla mobilityrecordedbywearabledevicesandgoldstandardsthemobilisedprocedurefordatastandardization
AT deldinsilvia mobilityrecordedbywearabledevicesandgoldstandardsthemobilisedprocedurefordatastandardization
AT micoamigomencarna mobilityrecordedbywearabledevicesandgoldstandardsthemobilisedprocedurefordatastandardization
AT salisfrancesca mobilityrecordedbywearabledevicesandgoldstandardsthemobilisedprocedurefordatastandardization
AT bertulettistefano mobilityrecordedbywearabledevicesandgoldstandardsthemobilisedprocedurefordatastandardization
AT carusomarco mobilityrecordedbywearabledevicesandgoldstandardsthemobilisedprocedurefordatastandardization
AT cereattiandrea mobilityrecordedbywearabledevicesandgoldstandardsthemobilisedprocedurefordatastandardization
AT gaziteran mobilityrecordedbywearabledevicesandgoldstandardsthemobilisedprocedurefordatastandardization
AT paraschivionescuanisoara mobilityrecordedbywearabledevicesandgoldstandardsthemobilisedprocedurefordatastandardization
AT soltaniabolfazl mobilityrecordedbywearabledevicesandgoldstandardsthemobilisedprocedurefordatastandardization
AT klugefelix mobilityrecordedbywearabledevicesandgoldstandardsthemobilisedprocedurefordatastandardization
AT kuderlearne mobilityrecordedbywearabledevicesandgoldstandardsthemobilisedprocedurefordatastandardization
AT ullrichmartin mobilityrecordedbywearabledevicesandgoldstandardsthemobilisedprocedurefordatastandardization
AT kirkcameron mobilityrecordedbywearabledevicesandgoldstandardsthemobilisedprocedurefordatastandardization
AT hidenhugo mobilityrecordedbywearabledevicesandgoldstandardsthemobilisedprocedurefordatastandardization
AT dascanioilaria mobilityrecordedbywearabledevicesandgoldstandardsthemobilisedprocedurefordatastandardization
AT hansenclint mobilityrecordedbywearabledevicesandgoldstandardsthemobilisedprocedurefordatastandardization
AT rochesterlynn mobilityrecordedbywearabledevicesandgoldstandardsthemobilisedprocedurefordatastandardization
AT mazzaclaudia mobilityrecordedbywearabledevicesandgoldstandardsthemobilisedprocedurefordatastandardization
AT chiarilorenzo mobilityrecordedbywearabledevicesandgoldstandardsthemobilisedprocedurefordatastandardization