Cargando…
Effects of High-Intensity Laser Therapy (HILT) on Skin Surface Temperature and Vein Diameter in Healthy Racehorses with Clipped and Non-Clipped Coat
SIMPLE SUMMARY: The use of high-intensity laser therapy (HILT) has recently been introduced in equine veterinary medicine. The goal of the research was to evaluate the effects of HILT on skin surface temperature and vein diameter in the carpal joint region in 20 racehorses divided into two groups: w...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9854543/ https://www.ncbi.nlm.nih.gov/pubmed/36670756 http://dx.doi.org/10.3390/ani13020216 |
_version_ | 1784873146631847936 |
---|---|
author | Zielińska, Paulina Soroko-Dubrovina, Maria Śniegucka, Karolina Dudek, Krzysztof Čebulj-Kadunc, Nina |
author_facet | Zielińska, Paulina Soroko-Dubrovina, Maria Śniegucka, Karolina Dudek, Krzysztof Čebulj-Kadunc, Nina |
author_sort | Zielińska, Paulina |
collection | PubMed |
description | SIMPLE SUMMARY: The use of high-intensity laser therapy (HILT) has recently been introduced in equine veterinary medicine. The goal of the research was to evaluate the effects of HILT on skin surface temperature and vein diameter in the carpal joint region in 20 racehorses divided into two groups: with clipped (n = 10) and non-clipped coat (n = 10) in the area of application. The hypothesis was that HILT would lead to a greater increase in skin surface temperature and vein diameter in the clipped coat group than in the non-clipped group. Variations in vein diameter and skin surface temperature were assessed before and after HILT. The HILT treatment resulted in a greater increase in skin surface temperature in the non-clipped coat group horses compared to the clipped group, while vein diameter increased more in the clipped group horses compared to the non-clipped group. Larger increases in skin surface temperature can be achieved with a non-clipped coat. Coat clipping of the treatment area increases vein diameter, while reducing skin surface temperature. Further research is needed to specify the parameters for treatment of skin areas with clipped and non-clipped coat in order to perform effective laser therapy. ABSTRACT: The aim of this study was to investigate the differences in the effects of high-intensity laser therapy (HILT) on skin surface temperature and vein diameter in the carpal joint region in racehorses with clipped and non-clipped treatment areas. The study included 20 Thoroughbreds split into two equal groups: clipped coat and non-clipped coat. Horses underwent thermographic examination to detect changes in skin surface temperature at the medial surface of the carpal joint, followed by ultrasonographic examination to assess changes in the diameter of the medial palmar vein before and after HILT. The increase in skin surface temperature after HILT was significantly lower in the group with clipped coat than in the non-clipped group. The group with clipped coat showed a greater increase in vessel diameter. There was a significantly weak negative correlation between the changes in average skin surface temperature and vein diameter in both groups. In conclusion, an efficient photothermal effect can be achieved in skin with a non-clipped coat and clipping the treatment area increases photobiostimulation of the tissue, while reducing the photothermal effect. Further research is needed to specify the parameters for the treatment of skin with clipped and non-clipped coat in order to perform effective laser therapy. |
format | Online Article Text |
id | pubmed-9854543 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-98545432023-01-21 Effects of High-Intensity Laser Therapy (HILT) on Skin Surface Temperature and Vein Diameter in Healthy Racehorses with Clipped and Non-Clipped Coat Zielińska, Paulina Soroko-Dubrovina, Maria Śniegucka, Karolina Dudek, Krzysztof Čebulj-Kadunc, Nina Animals (Basel) Communication SIMPLE SUMMARY: The use of high-intensity laser therapy (HILT) has recently been introduced in equine veterinary medicine. The goal of the research was to evaluate the effects of HILT on skin surface temperature and vein diameter in the carpal joint region in 20 racehorses divided into two groups: with clipped (n = 10) and non-clipped coat (n = 10) in the area of application. The hypothesis was that HILT would lead to a greater increase in skin surface temperature and vein diameter in the clipped coat group than in the non-clipped group. Variations in vein diameter and skin surface temperature were assessed before and after HILT. The HILT treatment resulted in a greater increase in skin surface temperature in the non-clipped coat group horses compared to the clipped group, while vein diameter increased more in the clipped group horses compared to the non-clipped group. Larger increases in skin surface temperature can be achieved with a non-clipped coat. Coat clipping of the treatment area increases vein diameter, while reducing skin surface temperature. Further research is needed to specify the parameters for treatment of skin areas with clipped and non-clipped coat in order to perform effective laser therapy. ABSTRACT: The aim of this study was to investigate the differences in the effects of high-intensity laser therapy (HILT) on skin surface temperature and vein diameter in the carpal joint region in racehorses with clipped and non-clipped treatment areas. The study included 20 Thoroughbreds split into two equal groups: clipped coat and non-clipped coat. Horses underwent thermographic examination to detect changes in skin surface temperature at the medial surface of the carpal joint, followed by ultrasonographic examination to assess changes in the diameter of the medial palmar vein before and after HILT. The increase in skin surface temperature after HILT was significantly lower in the group with clipped coat than in the non-clipped group. The group with clipped coat showed a greater increase in vessel diameter. There was a significantly weak negative correlation between the changes in average skin surface temperature and vein diameter in both groups. In conclusion, an efficient photothermal effect can be achieved in skin with a non-clipped coat and clipping the treatment area increases photobiostimulation of the tissue, while reducing the photothermal effect. Further research is needed to specify the parameters for the treatment of skin with clipped and non-clipped coat in order to perform effective laser therapy. MDPI 2023-01-06 /pmc/articles/PMC9854543/ /pubmed/36670756 http://dx.doi.org/10.3390/ani13020216 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Communication Zielińska, Paulina Soroko-Dubrovina, Maria Śniegucka, Karolina Dudek, Krzysztof Čebulj-Kadunc, Nina Effects of High-Intensity Laser Therapy (HILT) on Skin Surface Temperature and Vein Diameter in Healthy Racehorses with Clipped and Non-Clipped Coat |
title | Effects of High-Intensity Laser Therapy (HILT) on Skin Surface Temperature and Vein Diameter in Healthy Racehorses with Clipped and Non-Clipped Coat |
title_full | Effects of High-Intensity Laser Therapy (HILT) on Skin Surface Temperature and Vein Diameter in Healthy Racehorses with Clipped and Non-Clipped Coat |
title_fullStr | Effects of High-Intensity Laser Therapy (HILT) on Skin Surface Temperature and Vein Diameter in Healthy Racehorses with Clipped and Non-Clipped Coat |
title_full_unstemmed | Effects of High-Intensity Laser Therapy (HILT) on Skin Surface Temperature and Vein Diameter in Healthy Racehorses with Clipped and Non-Clipped Coat |
title_short | Effects of High-Intensity Laser Therapy (HILT) on Skin Surface Temperature and Vein Diameter in Healthy Racehorses with Clipped and Non-Clipped Coat |
title_sort | effects of high-intensity laser therapy (hilt) on skin surface temperature and vein diameter in healthy racehorses with clipped and non-clipped coat |
topic | Communication |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9854543/ https://www.ncbi.nlm.nih.gov/pubmed/36670756 http://dx.doi.org/10.3390/ani13020216 |
work_keys_str_mv | AT zielinskapaulina effectsofhighintensitylasertherapyhiltonskinsurfacetemperatureandveindiameterinhealthyracehorseswithclippedandnonclippedcoat AT sorokodubrovinamaria effectsofhighintensitylasertherapyhiltonskinsurfacetemperatureandveindiameterinhealthyracehorseswithclippedandnonclippedcoat AT snieguckakarolina effectsofhighintensitylasertherapyhiltonskinsurfacetemperatureandveindiameterinhealthyracehorseswithclippedandnonclippedcoat AT dudekkrzysztof effectsofhighintensitylasertherapyhiltonskinsurfacetemperatureandveindiameterinhealthyracehorseswithclippedandnonclippedcoat AT cebuljkaduncnina effectsofhighintensitylasertherapyhiltonskinsurfacetemperatureandveindiameterinhealthyracehorseswithclippedandnonclippedcoat |