Cargando…

An insight to the internal quality control of blood components separated using the latest whole blood collection and processing systems: Experience from a tertiary care hospital blood transfusion service in Eastern India

BACKGROUND: With blood component therapy becoming the standard of care in transfusion medicine globally, the quality control (QC) of these components has become a routine and mandatory program in all blood centers. Extensive utilization of blood components has been observed in our multidisciplinary...

Descripción completa

Detalles Bibliográficos
Autores principales: Das, Sudipta Sekhar, Biswas, Rathindra Nath, Sardar, Tirtha Pratim, Safi, Mahammad
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9855214/
https://www.ncbi.nlm.nih.gov/pubmed/36687542
http://dx.doi.org/10.4103/ajts.ajts_52_21
_version_ 1784873325141426176
author Das, Sudipta Sekhar
Biswas, Rathindra Nath
Sardar, Tirtha Pratim
Safi, Mahammad
author_facet Das, Sudipta Sekhar
Biswas, Rathindra Nath
Sardar, Tirtha Pratim
Safi, Mahammad
author_sort Das, Sudipta Sekhar
collection PubMed
description BACKGROUND: With blood component therapy becoming the standard of care in transfusion medicine globally, the quality control (QC) of these components has become a routine and mandatory program in all blood centers. Extensive utilization of blood components has been observed in our multidisciplinary tertiary care hospital. We use quadruple bag systems and automated component extraction facilities for collection and processing of whole blood (WB). In this study, we analyzed our data relating to QC of all blood components which we prepare and issue for transfusion. MATERIALS AND METHODS: The retrospective 5-year study comprised 47,430 WB collections which were separated into blood components using quadruple bags and automated component extraction machine. A total of 90 units of WB were processed into blood components for the machine calibration and validation. Routine use of the system was started once the calibration and validation results were acceptable. At least 1% of each component prepared was subjected to QC as per departmental standard operating procedures. Statistical analysis was done using the SPSS statistical package. RESULTS: The mean volume, hematocrit (Hct), platelet (PLT), and white blood cell (WBC) in 350 and 450 mL WB units were 394.63 mL, 39.43%, 0.93 × 10(11), and 3.12 × 10(9) and 507.75 mL, 40.72%, 1.13 × 10(11), and 3.45 × 10(9), respectively, with mean recovery of PLT and WBC in buffy coat being 95.54% and 68.63% and 97.87% and 74.51%, respectively. As high as 89.91% RBC recovery was noted in the packed red blood cell units which were subjected to QC. QC of random donor platelets was performed in 979 (2.36%) units with acceptable results. The mean fibrinogen and FVIII values were estimated to be 469.17 mg and 217.34 IU (1.07 IU/mL) and 600.21 mg and 273.39 IU (1.11 IU/mL) in fresh frozen plasma units prepared from 350 and 450 mL WB, respectively. A total of 578 (1.62%) units of cryoprecipitate were investigated for QC with favorable results. CONCLUSION: We conclude that QC data generated in this study will provide invaluable information about the performance of the latest blood collection systems. QC of all blood components under study complied with both national and international standards. We opine that all blood centers should establish a complete QC program and adhere to departmental protocols and manufacturer's instructions for its execution and effective outcome.
format Online
Article
Text
id pubmed-9855214
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-98552142023-01-21 An insight to the internal quality control of blood components separated using the latest whole blood collection and processing systems: Experience from a tertiary care hospital blood transfusion service in Eastern India Das, Sudipta Sekhar Biswas, Rathindra Nath Sardar, Tirtha Pratim Safi, Mahammad Asian J Transfus Sci Original Article BACKGROUND: With blood component therapy becoming the standard of care in transfusion medicine globally, the quality control (QC) of these components has become a routine and mandatory program in all blood centers. Extensive utilization of blood components has been observed in our multidisciplinary tertiary care hospital. We use quadruple bag systems and automated component extraction facilities for collection and processing of whole blood (WB). In this study, we analyzed our data relating to QC of all blood components which we prepare and issue for transfusion. MATERIALS AND METHODS: The retrospective 5-year study comprised 47,430 WB collections which were separated into blood components using quadruple bags and automated component extraction machine. A total of 90 units of WB were processed into blood components for the machine calibration and validation. Routine use of the system was started once the calibration and validation results were acceptable. At least 1% of each component prepared was subjected to QC as per departmental standard operating procedures. Statistical analysis was done using the SPSS statistical package. RESULTS: The mean volume, hematocrit (Hct), platelet (PLT), and white blood cell (WBC) in 350 and 450 mL WB units were 394.63 mL, 39.43%, 0.93 × 10(11), and 3.12 × 10(9) and 507.75 mL, 40.72%, 1.13 × 10(11), and 3.45 × 10(9), respectively, with mean recovery of PLT and WBC in buffy coat being 95.54% and 68.63% and 97.87% and 74.51%, respectively. As high as 89.91% RBC recovery was noted in the packed red blood cell units which were subjected to QC. QC of random donor platelets was performed in 979 (2.36%) units with acceptable results. The mean fibrinogen and FVIII values were estimated to be 469.17 mg and 217.34 IU (1.07 IU/mL) and 600.21 mg and 273.39 IU (1.11 IU/mL) in fresh frozen plasma units prepared from 350 and 450 mL WB, respectively. A total of 578 (1.62%) units of cryoprecipitate were investigated for QC with favorable results. CONCLUSION: We conclude that QC data generated in this study will provide invaluable information about the performance of the latest blood collection systems. QC of all blood components under study complied with both national and international standards. We opine that all blood centers should establish a complete QC program and adhere to departmental protocols and manufacturer's instructions for its execution and effective outcome. Wolters Kluwer - Medknow 2022 2022-05-26 /pmc/articles/PMC9855214/ /pubmed/36687542 http://dx.doi.org/10.4103/ajts.ajts_52_21 Text en Copyright: © 2022 Asian Journal of Transfusion Science https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Das, Sudipta Sekhar
Biswas, Rathindra Nath
Sardar, Tirtha Pratim
Safi, Mahammad
An insight to the internal quality control of blood components separated using the latest whole blood collection and processing systems: Experience from a tertiary care hospital blood transfusion service in Eastern India
title An insight to the internal quality control of blood components separated using the latest whole blood collection and processing systems: Experience from a tertiary care hospital blood transfusion service in Eastern India
title_full An insight to the internal quality control of blood components separated using the latest whole blood collection and processing systems: Experience from a tertiary care hospital blood transfusion service in Eastern India
title_fullStr An insight to the internal quality control of blood components separated using the latest whole blood collection and processing systems: Experience from a tertiary care hospital blood transfusion service in Eastern India
title_full_unstemmed An insight to the internal quality control of blood components separated using the latest whole blood collection and processing systems: Experience from a tertiary care hospital blood transfusion service in Eastern India
title_short An insight to the internal quality control of blood components separated using the latest whole blood collection and processing systems: Experience from a tertiary care hospital blood transfusion service in Eastern India
title_sort insight to the internal quality control of blood components separated using the latest whole blood collection and processing systems: experience from a tertiary care hospital blood transfusion service in eastern india
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9855214/
https://www.ncbi.nlm.nih.gov/pubmed/36687542
http://dx.doi.org/10.4103/ajts.ajts_52_21
work_keys_str_mv AT dassudiptasekhar aninsighttotheinternalqualitycontrolofbloodcomponentsseparatedusingthelatestwholebloodcollectionandprocessingsystemsexperiencefromatertiarycarehospitalbloodtransfusionserviceineasternindia
AT biswasrathindranath aninsighttotheinternalqualitycontrolofbloodcomponentsseparatedusingthelatestwholebloodcollectionandprocessingsystemsexperiencefromatertiarycarehospitalbloodtransfusionserviceineasternindia
AT sardartirthapratim aninsighttotheinternalqualitycontrolofbloodcomponentsseparatedusingthelatestwholebloodcollectionandprocessingsystemsexperiencefromatertiarycarehospitalbloodtransfusionserviceineasternindia
AT safimahammad aninsighttotheinternalqualitycontrolofbloodcomponentsseparatedusingthelatestwholebloodcollectionandprocessingsystemsexperiencefromatertiarycarehospitalbloodtransfusionserviceineasternindia
AT dassudiptasekhar insighttotheinternalqualitycontrolofbloodcomponentsseparatedusingthelatestwholebloodcollectionandprocessingsystemsexperiencefromatertiarycarehospitalbloodtransfusionserviceineasternindia
AT biswasrathindranath insighttotheinternalqualitycontrolofbloodcomponentsseparatedusingthelatestwholebloodcollectionandprocessingsystemsexperiencefromatertiarycarehospitalbloodtransfusionserviceineasternindia
AT sardartirthapratim insighttotheinternalqualitycontrolofbloodcomponentsseparatedusingthelatestwholebloodcollectionandprocessingsystemsexperiencefromatertiarycarehospitalbloodtransfusionserviceineasternindia
AT safimahammad insighttotheinternalqualitycontrolofbloodcomponentsseparatedusingthelatestwholebloodcollectionandprocessingsystemsexperiencefromatertiarycarehospitalbloodtransfusionserviceineasternindia