Cargando…
Tolerance levels of mass density for adaptive helical tomotherapy using MVCT
Daily dose distributions for adaptive radiotherapy (ART) using helical tomotherapy (HT) are calculated using megavoltage computed tomography (MVCT). Generally, the MVCT number is converted to mass density (MD) using an MD calibration table (MVCT-MD table). The aims of this study are to calculate the...
Autores principales: | , , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Oxford University Press
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9855312/ http://dx.doi.org/10.1093/jrr/rrac071 |
_version_ | 1784873348092657664 |
---|---|
author | Tsunemine, Shogo Ozawa, Shuichi Nakao, Minoru Miura, Hideharu Saito, Akito Kawahara, Daisuke Onishi, Yasuhiko Onishi, Takashi Okawa, Fumito Terai, Atsushi Hashiguchi, Taiki Yamasaki, Hidetoshi Maruta, Tsutomu Murakami, Yuji Nagata, Yasushi |
author_facet | Tsunemine, Shogo Ozawa, Shuichi Nakao, Minoru Miura, Hideharu Saito, Akito Kawahara, Daisuke Onishi, Yasuhiko Onishi, Takashi Okawa, Fumito Terai, Atsushi Hashiguchi, Taiki Yamasaki, Hidetoshi Maruta, Tsutomu Murakami, Yuji Nagata, Yasushi |
author_sort | Tsunemine, Shogo |
collection | PubMed |
description | Daily dose distributions for adaptive radiotherapy (ART) using helical tomotherapy (HT) are calculated using megavoltage computed tomography (MVCT). Generally, the MVCT number is converted to mass density (MD) using an MD calibration table (MVCT-MD table). The aims of this study are to calculate the tolerance levels of the MD for ART and to evaluate the tolerance levels using clinical patient plans. These tolerance levels of MD were calculated based on the tissue maximum ratio (TMR) of 6MV flattening-filter-free (FFF) beam of HT and the effective tissue thickness data from an International Commission on Radiological Protection 110 phantom data for lung, adipose/muscle and cartilage/spongy-bone. These tolerance levels were determined by considering both the MD causing a dose error of 2% and the variation in MVCT numbers. Subsequently, the stability of the MD values was estimated with the standard deviations (SD) in the MVCT number over 6 months. The dose distribution for clinical patient plans was calculated using the MVCT-MD table with added tolerance levels. These tolerance levels were determined as MD differences causing a dose error of 2%, and were ± 0.049 g/cm(3), ± 0.030 g/cm(3) and ± 0.049 g/cm(3) for lung, adipose/muscle and cartilage/spongy-bone, respectively. The calculated dose distribution errors using the MVCT-MD table added tolerance levels were within 2%. We proposed these tolerance levels in MD for the quality control of the MVCT-MD table. |
format | Online Article Text |
id | pubmed-9855312 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Oxford University Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-98553122023-01-23 Tolerance levels of mass density for adaptive helical tomotherapy using MVCT Tsunemine, Shogo Ozawa, Shuichi Nakao, Minoru Miura, Hideharu Saito, Akito Kawahara, Daisuke Onishi, Yasuhiko Onishi, Takashi Okawa, Fumito Terai, Atsushi Hashiguchi, Taiki Yamasaki, Hidetoshi Maruta, Tsutomu Murakami, Yuji Nagata, Yasushi J Radiat Res Announcement Daily dose distributions for adaptive radiotherapy (ART) using helical tomotherapy (HT) are calculated using megavoltage computed tomography (MVCT). Generally, the MVCT number is converted to mass density (MD) using an MD calibration table (MVCT-MD table). The aims of this study are to calculate the tolerance levels of the MD for ART and to evaluate the tolerance levels using clinical patient plans. These tolerance levels of MD were calculated based on the tissue maximum ratio (TMR) of 6MV flattening-filter-free (FFF) beam of HT and the effective tissue thickness data from an International Commission on Radiological Protection 110 phantom data for lung, adipose/muscle and cartilage/spongy-bone. These tolerance levels were determined by considering both the MD causing a dose error of 2% and the variation in MVCT numbers. Subsequently, the stability of the MD values was estimated with the standard deviations (SD) in the MVCT number over 6 months. The dose distribution for clinical patient plans was calculated using the MVCT-MD table with added tolerance levels. These tolerance levels were determined as MD differences causing a dose error of 2%, and were ± 0.049 g/cm(3), ± 0.030 g/cm(3) and ± 0.049 g/cm(3) for lung, adipose/muscle and cartilage/spongy-bone, respectively. The calculated dose distribution errors using the MVCT-MD table added tolerance levels were within 2%. We proposed these tolerance levels in MD for the quality control of the MVCT-MD table. Oxford University Press 2022-11-14 /pmc/articles/PMC9855312/ http://dx.doi.org/10.1093/jrr/rrac071 Text en © The Author(s) 2022. Published by Oxford University Press on behalf of The Japanese Radiation Research Society and Japanese Society for Radiation Oncology. https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Announcement Tsunemine, Shogo Ozawa, Shuichi Nakao, Minoru Miura, Hideharu Saito, Akito Kawahara, Daisuke Onishi, Yasuhiko Onishi, Takashi Okawa, Fumito Terai, Atsushi Hashiguchi, Taiki Yamasaki, Hidetoshi Maruta, Tsutomu Murakami, Yuji Nagata, Yasushi Tolerance levels of mass density for adaptive helical tomotherapy using MVCT |
title | Tolerance levels of mass density for adaptive helical tomotherapy using MVCT |
title_full | Tolerance levels of mass density for adaptive helical tomotherapy using MVCT |
title_fullStr | Tolerance levels of mass density for adaptive helical tomotherapy using MVCT |
title_full_unstemmed | Tolerance levels of mass density for adaptive helical tomotherapy using MVCT |
title_short | Tolerance levels of mass density for adaptive helical tomotherapy using MVCT |
title_sort | tolerance levels of mass density for adaptive helical tomotherapy using mvct |
topic | Announcement |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9855312/ http://dx.doi.org/10.1093/jrr/rrac071 |
work_keys_str_mv | AT tsunemineshogo tolerancelevelsofmassdensityforadaptivehelicaltomotherapyusingmvct AT ozawashuichi tolerancelevelsofmassdensityforadaptivehelicaltomotherapyusingmvct AT nakaominoru tolerancelevelsofmassdensityforadaptivehelicaltomotherapyusingmvct AT miurahideharu tolerancelevelsofmassdensityforadaptivehelicaltomotherapyusingmvct AT saitoakito tolerancelevelsofmassdensityforadaptivehelicaltomotherapyusingmvct AT kawaharadaisuke tolerancelevelsofmassdensityforadaptivehelicaltomotherapyusingmvct AT onishiyasuhiko tolerancelevelsofmassdensityforadaptivehelicaltomotherapyusingmvct AT onishitakashi tolerancelevelsofmassdensityforadaptivehelicaltomotherapyusingmvct AT okawafumito tolerancelevelsofmassdensityforadaptivehelicaltomotherapyusingmvct AT teraiatsushi tolerancelevelsofmassdensityforadaptivehelicaltomotherapyusingmvct AT hashiguchitaiki tolerancelevelsofmassdensityforadaptivehelicaltomotherapyusingmvct AT yamasakihidetoshi tolerancelevelsofmassdensityforadaptivehelicaltomotherapyusingmvct AT marutatsutomu tolerancelevelsofmassdensityforadaptivehelicaltomotherapyusingmvct AT murakamiyuji tolerancelevelsofmassdensityforadaptivehelicaltomotherapyusingmvct AT nagatayasushi tolerancelevelsofmassdensityforadaptivehelicaltomotherapyusingmvct |