Cargando…

Tolerance levels of mass density for adaptive helical tomotherapy using MVCT

Daily dose distributions for adaptive radiotherapy (ART) using helical tomotherapy (HT) are calculated using megavoltage computed tomography (MVCT). Generally, the MVCT number is converted to mass density (MD) using an MD calibration table (MVCT-MD table). The aims of this study are to calculate the...

Descripción completa

Detalles Bibliográficos
Autores principales: Tsunemine, Shogo, Ozawa, Shuichi, Nakao, Minoru, Miura, Hideharu, Saito, Akito, Kawahara, Daisuke, Onishi, Yasuhiko, Onishi, Takashi, Okawa, Fumito, Terai, Atsushi, Hashiguchi, Taiki, Yamasaki, Hidetoshi, Maruta, Tsutomu, Murakami, Yuji, Nagata, Yasushi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9855312/
http://dx.doi.org/10.1093/jrr/rrac071
_version_ 1784873348092657664
author Tsunemine, Shogo
Ozawa, Shuichi
Nakao, Minoru
Miura, Hideharu
Saito, Akito
Kawahara, Daisuke
Onishi, Yasuhiko
Onishi, Takashi
Okawa, Fumito
Terai, Atsushi
Hashiguchi, Taiki
Yamasaki, Hidetoshi
Maruta, Tsutomu
Murakami, Yuji
Nagata, Yasushi
author_facet Tsunemine, Shogo
Ozawa, Shuichi
Nakao, Minoru
Miura, Hideharu
Saito, Akito
Kawahara, Daisuke
Onishi, Yasuhiko
Onishi, Takashi
Okawa, Fumito
Terai, Atsushi
Hashiguchi, Taiki
Yamasaki, Hidetoshi
Maruta, Tsutomu
Murakami, Yuji
Nagata, Yasushi
author_sort Tsunemine, Shogo
collection PubMed
description Daily dose distributions for adaptive radiotherapy (ART) using helical tomotherapy (HT) are calculated using megavoltage computed tomography (MVCT). Generally, the MVCT number is converted to mass density (MD) using an MD calibration table (MVCT-MD table). The aims of this study are to calculate the tolerance levels of the MD for ART and to evaluate the tolerance levels using clinical patient plans. These tolerance levels of MD were calculated based on the tissue maximum ratio (TMR) of 6MV flattening-filter-free (FFF) beam of HT and the effective tissue thickness data from an International Commission on Radiological Protection 110 phantom data for lung, adipose/muscle and cartilage/spongy-bone. These tolerance levels were determined by considering both the MD causing a dose error of 2% and the variation in MVCT numbers. Subsequently, the stability of the MD values was estimated with the standard deviations (SD) in the MVCT number over 6 months. The dose distribution for clinical patient plans was calculated using the MVCT-MD table with added tolerance levels. These tolerance levels were determined as MD differences causing a dose error of 2%, and were ± 0.049 g/cm(3), ± 0.030 g/cm(3) and ± 0.049 g/cm(3) for lung, adipose/muscle and cartilage/spongy-bone, respectively. The calculated dose distribution errors using the MVCT-MD table added tolerance levels were within 2%. We proposed these tolerance levels in MD for the quality control of the MVCT-MD table.
format Online
Article
Text
id pubmed-9855312
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-98553122023-01-23 Tolerance levels of mass density for adaptive helical tomotherapy using MVCT Tsunemine, Shogo Ozawa, Shuichi Nakao, Minoru Miura, Hideharu Saito, Akito Kawahara, Daisuke Onishi, Yasuhiko Onishi, Takashi Okawa, Fumito Terai, Atsushi Hashiguchi, Taiki Yamasaki, Hidetoshi Maruta, Tsutomu Murakami, Yuji Nagata, Yasushi J Radiat Res Announcement Daily dose distributions for adaptive radiotherapy (ART) using helical tomotherapy (HT) are calculated using megavoltage computed tomography (MVCT). Generally, the MVCT number is converted to mass density (MD) using an MD calibration table (MVCT-MD table). The aims of this study are to calculate the tolerance levels of the MD for ART and to evaluate the tolerance levels using clinical patient plans. These tolerance levels of MD were calculated based on the tissue maximum ratio (TMR) of 6MV flattening-filter-free (FFF) beam of HT and the effective tissue thickness data from an International Commission on Radiological Protection 110 phantom data for lung, adipose/muscle and cartilage/spongy-bone. These tolerance levels were determined by considering both the MD causing a dose error of 2% and the variation in MVCT numbers. Subsequently, the stability of the MD values was estimated with the standard deviations (SD) in the MVCT number over 6 months. The dose distribution for clinical patient plans was calculated using the MVCT-MD table with added tolerance levels. These tolerance levels were determined as MD differences causing a dose error of 2%, and were ± 0.049 g/cm(3), ± 0.030 g/cm(3) and ± 0.049 g/cm(3) for lung, adipose/muscle and cartilage/spongy-bone, respectively. The calculated dose distribution errors using the MVCT-MD table added tolerance levels were within 2%. We proposed these tolerance levels in MD for the quality control of the MVCT-MD table. Oxford University Press 2022-11-14 /pmc/articles/PMC9855312/ http://dx.doi.org/10.1093/jrr/rrac071 Text en © The Author(s) 2022. Published by Oxford University Press on behalf of The Japanese Radiation Research Society and Japanese Society for Radiation Oncology. https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Announcement
Tsunemine, Shogo
Ozawa, Shuichi
Nakao, Minoru
Miura, Hideharu
Saito, Akito
Kawahara, Daisuke
Onishi, Yasuhiko
Onishi, Takashi
Okawa, Fumito
Terai, Atsushi
Hashiguchi, Taiki
Yamasaki, Hidetoshi
Maruta, Tsutomu
Murakami, Yuji
Nagata, Yasushi
Tolerance levels of mass density for adaptive helical tomotherapy using MVCT
title Tolerance levels of mass density for adaptive helical tomotherapy using MVCT
title_full Tolerance levels of mass density for adaptive helical tomotherapy using MVCT
title_fullStr Tolerance levels of mass density for adaptive helical tomotherapy using MVCT
title_full_unstemmed Tolerance levels of mass density for adaptive helical tomotherapy using MVCT
title_short Tolerance levels of mass density for adaptive helical tomotherapy using MVCT
title_sort tolerance levels of mass density for adaptive helical tomotherapy using mvct
topic Announcement
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9855312/
http://dx.doi.org/10.1093/jrr/rrac071
work_keys_str_mv AT tsunemineshogo tolerancelevelsofmassdensityforadaptivehelicaltomotherapyusingmvct
AT ozawashuichi tolerancelevelsofmassdensityforadaptivehelicaltomotherapyusingmvct
AT nakaominoru tolerancelevelsofmassdensityforadaptivehelicaltomotherapyusingmvct
AT miurahideharu tolerancelevelsofmassdensityforadaptivehelicaltomotherapyusingmvct
AT saitoakito tolerancelevelsofmassdensityforadaptivehelicaltomotherapyusingmvct
AT kawaharadaisuke tolerancelevelsofmassdensityforadaptivehelicaltomotherapyusingmvct
AT onishiyasuhiko tolerancelevelsofmassdensityforadaptivehelicaltomotherapyusingmvct
AT onishitakashi tolerancelevelsofmassdensityforadaptivehelicaltomotherapyusingmvct
AT okawafumito tolerancelevelsofmassdensityforadaptivehelicaltomotherapyusingmvct
AT teraiatsushi tolerancelevelsofmassdensityforadaptivehelicaltomotherapyusingmvct
AT hashiguchitaiki tolerancelevelsofmassdensityforadaptivehelicaltomotherapyusingmvct
AT yamasakihidetoshi tolerancelevelsofmassdensityforadaptivehelicaltomotherapyusingmvct
AT marutatsutomu tolerancelevelsofmassdensityforadaptivehelicaltomotherapyusingmvct
AT murakamiyuji tolerancelevelsofmassdensityforadaptivehelicaltomotherapyusingmvct
AT nagatayasushi tolerancelevelsofmassdensityforadaptivehelicaltomotherapyusingmvct