Cargando…

Palladium Hydroxide (Pearlman’s Catalyst) Doped MXene (Ti(3)C(2)Tx) Composite Modified Electrode for Selective Detection of Nicotine in Human Sweat

High concentrations of nicotine (40 to 60 mg) are more dangerous for adults who weigh about 70 kg. Herein, we developed an electrochemical transducer using an MXene (Ti(3)C(2)Tx)/palladium hydroxide-supported carbon (Pearlman’s catalyst) composite (MXene/Pd(OH)(2)/C) for the identification of nicoti...

Descripción completa

Detalles Bibliográficos
Autores principales: Magesh, Vasanth, Sundramoorthy, Ashok K., Ganapathy, Dhanraj, Atchudan, Raji, Arya, Sandeep, Alshgari, Razan A., Aljuwayid, Ahmed Muteb
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9856038/
https://www.ncbi.nlm.nih.gov/pubmed/36671889
http://dx.doi.org/10.3390/bios13010054
_version_ 1784873523613794304
author Magesh, Vasanth
Sundramoorthy, Ashok K.
Ganapathy, Dhanraj
Atchudan, Raji
Arya, Sandeep
Alshgari, Razan A.
Aljuwayid, Ahmed Muteb
author_facet Magesh, Vasanth
Sundramoorthy, Ashok K.
Ganapathy, Dhanraj
Atchudan, Raji
Arya, Sandeep
Alshgari, Razan A.
Aljuwayid, Ahmed Muteb
author_sort Magesh, Vasanth
collection PubMed
description High concentrations of nicotine (40 to 60 mg) are more dangerous for adults who weigh about 70 kg. Herein, we developed an electrochemical transducer using an MXene (Ti(3)C(2)Tx)/palladium hydroxide-supported carbon (Pearlman’s catalyst) composite (MXene/Pd(OH)(2)/C) for the identification of nicotine levels in human sweat. Firstly, the MXene was doped with Pd(OH)(2)/C (PHC) by mechanical grinding followed by an ultrasonication process to obtain the MXene/PHC composite. Secondly, XRD, Raman, FE-SEM, EDS and E-mapping analysis were utilized to confirm the successful formation of MXene/PHC composite. Using MXene/PHC composite dispersion, an MXene/PHC composite-modified glassy carbon electrode (MXene/PHC/GCE) was prepared, which showed high sensitivity as well as selectivity towards nicotine (300 µM NIC) oxidation in 0.1 M phosphate buffer (pH = 7.4) by cyclic voltammetry (CV) and amperometry. The MXene/PHC/GCE had reduced the over potential of nicotine oxidation (about 200 mV) and also enhanced the oxidation peak current (8.9 µA) compared to bare/GCE (2.1 µA) and MXene/GCE (5.5 µA). Moreover, the optimized experimental condition was used for the quantification of NIC from 0.25 µM to 37.5 µM. The limit of detection (LOD) and sensitivity were 27 nM and 0.286 µA µM(−1) cm(2), respectively. The MXene/PHC/GCE was also tested in the presence of Na(+), Mg(2+), Ca(2+), hydrogen peroxide, acetic acid, ascorbic acid, dopamine and glucose. These molecules were not interfered during NIC analysis, which indicated the good selectivity of the MXene/PHC/GCE sensor. In addition, electrochemical determination of NIC was successfully carried out in the human sweat samples collected from a tobacco smoker. The recovery percentage of NIC in the sweat sample was 97%. Finally, we concluded that the MXene/PHC composite-based sensor can be prepared for the accurate determination of NIC with high sensitivity, selectivity and stability in human sweat samples.
format Online
Article
Text
id pubmed-9856038
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-98560382023-01-21 Palladium Hydroxide (Pearlman’s Catalyst) Doped MXene (Ti(3)C(2)Tx) Composite Modified Electrode for Selective Detection of Nicotine in Human Sweat Magesh, Vasanth Sundramoorthy, Ashok K. Ganapathy, Dhanraj Atchudan, Raji Arya, Sandeep Alshgari, Razan A. Aljuwayid, Ahmed Muteb Biosensors (Basel) Article High concentrations of nicotine (40 to 60 mg) are more dangerous for adults who weigh about 70 kg. Herein, we developed an electrochemical transducer using an MXene (Ti(3)C(2)Tx)/palladium hydroxide-supported carbon (Pearlman’s catalyst) composite (MXene/Pd(OH)(2)/C) for the identification of nicotine levels in human sweat. Firstly, the MXene was doped with Pd(OH)(2)/C (PHC) by mechanical grinding followed by an ultrasonication process to obtain the MXene/PHC composite. Secondly, XRD, Raman, FE-SEM, EDS and E-mapping analysis were utilized to confirm the successful formation of MXene/PHC composite. Using MXene/PHC composite dispersion, an MXene/PHC composite-modified glassy carbon electrode (MXene/PHC/GCE) was prepared, which showed high sensitivity as well as selectivity towards nicotine (300 µM NIC) oxidation in 0.1 M phosphate buffer (pH = 7.4) by cyclic voltammetry (CV) and amperometry. The MXene/PHC/GCE had reduced the over potential of nicotine oxidation (about 200 mV) and also enhanced the oxidation peak current (8.9 µA) compared to bare/GCE (2.1 µA) and MXene/GCE (5.5 µA). Moreover, the optimized experimental condition was used for the quantification of NIC from 0.25 µM to 37.5 µM. The limit of detection (LOD) and sensitivity were 27 nM and 0.286 µA µM(−1) cm(2), respectively. The MXene/PHC/GCE was also tested in the presence of Na(+), Mg(2+), Ca(2+), hydrogen peroxide, acetic acid, ascorbic acid, dopamine and glucose. These molecules were not interfered during NIC analysis, which indicated the good selectivity of the MXene/PHC/GCE sensor. In addition, electrochemical determination of NIC was successfully carried out in the human sweat samples collected from a tobacco smoker. The recovery percentage of NIC in the sweat sample was 97%. Finally, we concluded that the MXene/PHC composite-based sensor can be prepared for the accurate determination of NIC with high sensitivity, selectivity and stability in human sweat samples. MDPI 2022-12-29 /pmc/articles/PMC9856038/ /pubmed/36671889 http://dx.doi.org/10.3390/bios13010054 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Magesh, Vasanth
Sundramoorthy, Ashok K.
Ganapathy, Dhanraj
Atchudan, Raji
Arya, Sandeep
Alshgari, Razan A.
Aljuwayid, Ahmed Muteb
Palladium Hydroxide (Pearlman’s Catalyst) Doped MXene (Ti(3)C(2)Tx) Composite Modified Electrode for Selective Detection of Nicotine in Human Sweat
title Palladium Hydroxide (Pearlman’s Catalyst) Doped MXene (Ti(3)C(2)Tx) Composite Modified Electrode for Selective Detection of Nicotine in Human Sweat
title_full Palladium Hydroxide (Pearlman’s Catalyst) Doped MXene (Ti(3)C(2)Tx) Composite Modified Electrode for Selective Detection of Nicotine in Human Sweat
title_fullStr Palladium Hydroxide (Pearlman’s Catalyst) Doped MXene (Ti(3)C(2)Tx) Composite Modified Electrode for Selective Detection of Nicotine in Human Sweat
title_full_unstemmed Palladium Hydroxide (Pearlman’s Catalyst) Doped MXene (Ti(3)C(2)Tx) Composite Modified Electrode for Selective Detection of Nicotine in Human Sweat
title_short Palladium Hydroxide (Pearlman’s Catalyst) Doped MXene (Ti(3)C(2)Tx) Composite Modified Electrode for Selective Detection of Nicotine in Human Sweat
title_sort palladium hydroxide (pearlman’s catalyst) doped mxene (ti(3)c(2)tx) composite modified electrode for selective detection of nicotine in human sweat
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9856038/
https://www.ncbi.nlm.nih.gov/pubmed/36671889
http://dx.doi.org/10.3390/bios13010054
work_keys_str_mv AT mageshvasanth palladiumhydroxidepearlmanscatalystdopedmxeneti3c2txcompositemodifiedelectrodeforselectivedetectionofnicotineinhumansweat
AT sundramoorthyashokk palladiumhydroxidepearlmanscatalystdopedmxeneti3c2txcompositemodifiedelectrodeforselectivedetectionofnicotineinhumansweat
AT ganapathydhanraj palladiumhydroxidepearlmanscatalystdopedmxeneti3c2txcompositemodifiedelectrodeforselectivedetectionofnicotineinhumansweat
AT atchudanraji palladiumhydroxidepearlmanscatalystdopedmxeneti3c2txcompositemodifiedelectrodeforselectivedetectionofnicotineinhumansweat
AT aryasandeep palladiumhydroxidepearlmanscatalystdopedmxeneti3c2txcompositemodifiedelectrodeforselectivedetectionofnicotineinhumansweat
AT alshgarirazana palladiumhydroxidepearlmanscatalystdopedmxeneti3c2txcompositemodifiedelectrodeforselectivedetectionofnicotineinhumansweat
AT aljuwayidahmedmuteb palladiumhydroxidepearlmanscatalystdopedmxeneti3c2txcompositemodifiedelectrodeforselectivedetectionofnicotineinhumansweat