Cargando…
Accuracy of Augmented Reality–Assisted Navigation in Dental Implant Surgery: Systematic Review and Meta-analysis
BACKGROUND: The novel concept of immersive 3D augmented reality (AR) surgical navigation has recently been introduced in the medical field. This method allows surgeons to directly focus on the surgical objective without having to look at a separate monitor. In the dental field, the recently develope...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
JMIR Publications
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9856431/ https://www.ncbi.nlm.nih.gov/pubmed/36598798 http://dx.doi.org/10.2196/42040 |
_version_ | 1784873627986952192 |
---|---|
author | Mai, Hang-Nga Dam, Van Viet Lee, Du-Hyeong |
author_facet | Mai, Hang-Nga Dam, Van Viet Lee, Du-Hyeong |
author_sort | Mai, Hang-Nga |
collection | PubMed |
description | BACKGROUND: The novel concept of immersive 3D augmented reality (AR) surgical navigation has recently been introduced in the medical field. This method allows surgeons to directly focus on the surgical objective without having to look at a separate monitor. In the dental field, the recently developed AR-assisted dental implant navigation system (AR navigation), which uses innovative image technology to directly visualize and track a presurgical plan over an actual surgical site, has attracted great interest. OBJECTIVE: This study is the first systematic review and meta-analysis study that aimed to assess the accuracy of dental implants placed by AR navigation and compare it with that of the widely used implant placement methods, including the freehand method (FH), template-based static guidance (TG), and conventional navigation (CN). METHODS: Individual search strategies were used in PubMed (MEDLINE), Scopus, ScienceDirect, Cochrane Library, and Google Scholar to search for articles published until March 21, 2022. This study was performed in accordance with the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines and registered in the International Prospective Register of Systematic Reviews (PROSPERO) database. Peer-reviewed journal articles evaluating the positional deviations of dental implants placed using AR-assisted implant navigation systems were included. Cohen d statistical power analysis was used to investigate the effect size estimate and CIs of standardized mean differences (SMDs) between data sets. RESULTS: Among the 425 articles retrieved, 15 articles were considered eligible for narrative review, 8 articles were considered for single-arm meta-analysis, and 4 were included in a 2-arm meta-analysis. The mean lateral, global, depth, and angular deviations of the dental implant placed using AR navigation were 0.90 (95% CI 0.78-1.02) mm, 1.18 (95% CI 0.95-1.41) mm, 0.78 (95% CI 0.48-1.08) mm, and 3.96° (95% CI 3.45°-4.48°), respectively. The accuracy of AR navigation was significantly higher than that of the FH method (SMD=−1.01; 95% CI −1.47 to −0.55; P<.001) and CN method (SMD=−0.46; 95% CI −0.64 to −0.29; P<.001). However, the accuracies of the AR navigation and TG methods were similar (SMD=0.06; 95% CI −0.62 to 0.74; P=.73). CONCLUSIONS: The positional deviations of AR-navigated implant placements were within the safety zone, suggesting clinically acceptable accuracy of the AR navigation method. Moreover, the accuracy of AR implant navigation was comparable with that of the highly recommended dental implant–guided surgery method, TG, and superior to that of the conventional FH and CN methods. This review highlights the possibility of using AR navigation as an effective and accurate immersive surgical guide for dental implant placement. |
format | Online Article Text |
id | pubmed-9856431 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | JMIR Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-98564312023-01-21 Accuracy of Augmented Reality–Assisted Navigation in Dental Implant Surgery: Systematic Review and Meta-analysis Mai, Hang-Nga Dam, Van Viet Lee, Du-Hyeong J Med Internet Res Review BACKGROUND: The novel concept of immersive 3D augmented reality (AR) surgical navigation has recently been introduced in the medical field. This method allows surgeons to directly focus on the surgical objective without having to look at a separate monitor. In the dental field, the recently developed AR-assisted dental implant navigation system (AR navigation), which uses innovative image technology to directly visualize and track a presurgical plan over an actual surgical site, has attracted great interest. OBJECTIVE: This study is the first systematic review and meta-analysis study that aimed to assess the accuracy of dental implants placed by AR navigation and compare it with that of the widely used implant placement methods, including the freehand method (FH), template-based static guidance (TG), and conventional navigation (CN). METHODS: Individual search strategies were used in PubMed (MEDLINE), Scopus, ScienceDirect, Cochrane Library, and Google Scholar to search for articles published until March 21, 2022. This study was performed in accordance with the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines and registered in the International Prospective Register of Systematic Reviews (PROSPERO) database. Peer-reviewed journal articles evaluating the positional deviations of dental implants placed using AR-assisted implant navigation systems were included. Cohen d statistical power analysis was used to investigate the effect size estimate and CIs of standardized mean differences (SMDs) between data sets. RESULTS: Among the 425 articles retrieved, 15 articles were considered eligible for narrative review, 8 articles were considered for single-arm meta-analysis, and 4 were included in a 2-arm meta-analysis. The mean lateral, global, depth, and angular deviations of the dental implant placed using AR navigation were 0.90 (95% CI 0.78-1.02) mm, 1.18 (95% CI 0.95-1.41) mm, 0.78 (95% CI 0.48-1.08) mm, and 3.96° (95% CI 3.45°-4.48°), respectively. The accuracy of AR navigation was significantly higher than that of the FH method (SMD=−1.01; 95% CI −1.47 to −0.55; P<.001) and CN method (SMD=−0.46; 95% CI −0.64 to −0.29; P<.001). However, the accuracies of the AR navigation and TG methods were similar (SMD=0.06; 95% CI −0.62 to 0.74; P=.73). CONCLUSIONS: The positional deviations of AR-navigated implant placements were within the safety zone, suggesting clinically acceptable accuracy of the AR navigation method. Moreover, the accuracy of AR implant navigation was comparable with that of the highly recommended dental implant–guided surgery method, TG, and superior to that of the conventional FH and CN methods. This review highlights the possibility of using AR navigation as an effective and accurate immersive surgical guide for dental implant placement. JMIR Publications 2023-01-04 /pmc/articles/PMC9856431/ /pubmed/36598798 http://dx.doi.org/10.2196/42040 Text en ©Hang-Nga Mai, Van Viet Dam, Du-Hyeong Lee. Originally published in the Journal of Medical Internet Research (https://www.jmir.org), 04.01.2023. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work, first published in the Journal of Medical Internet Research, is properly cited. The complete bibliographic information, a link to the original publication on https://www.jmir.org/, as well as this copyright and license information must be included. |
spellingShingle | Review Mai, Hang-Nga Dam, Van Viet Lee, Du-Hyeong Accuracy of Augmented Reality–Assisted Navigation in Dental Implant Surgery: Systematic Review and Meta-analysis |
title | Accuracy of Augmented Reality–Assisted Navigation in Dental Implant Surgery: Systematic Review and Meta-analysis |
title_full | Accuracy of Augmented Reality–Assisted Navigation in Dental Implant Surgery: Systematic Review and Meta-analysis |
title_fullStr | Accuracy of Augmented Reality–Assisted Navigation in Dental Implant Surgery: Systematic Review and Meta-analysis |
title_full_unstemmed | Accuracy of Augmented Reality–Assisted Navigation in Dental Implant Surgery: Systematic Review and Meta-analysis |
title_short | Accuracy of Augmented Reality–Assisted Navigation in Dental Implant Surgery: Systematic Review and Meta-analysis |
title_sort | accuracy of augmented reality–assisted navigation in dental implant surgery: systematic review and meta-analysis |
topic | Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9856431/ https://www.ncbi.nlm.nih.gov/pubmed/36598798 http://dx.doi.org/10.2196/42040 |
work_keys_str_mv | AT maihangnga accuracyofaugmentedrealityassistednavigationindentalimplantsurgerysystematicreviewandmetaanalysis AT damvanviet accuracyofaugmentedrealityassistednavigationindentalimplantsurgerysystematicreviewandmetaanalysis AT leeduhyeong accuracyofaugmentedrealityassistednavigationindentalimplantsurgerysystematicreviewandmetaanalysis |