High-Frequency (30 MHz–6 GHz) Breast Tissue Characterization Stabilized by Suction Force for Intraoperative Tumor Margin Assessment
A gigahertz (GHz) range antenna formed by a coaxial probe has been applied for sensing cancerous breast lesions in the scanning platform with the assistance of a suction tube. The sensor structure was a planar central layer and a metallic sheath of size of 3 cm(2) connected to a network analyzer (ke...
Autores principales: | , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9857665/ https://www.ncbi.nlm.nih.gov/pubmed/36672989 http://dx.doi.org/10.3390/diagnostics13020179 |
_version_ | 1784873919831867392 |
---|---|
author | Mokhtari Dowlatabad, Hadi Mamdouh, Amir Yousefpour, Narges Mahdavi, Reihane Zandi, Ashkan Hoseinpour, Parisa Moosavi-Kiasari, Seyed Mohammad Sadegh Abbasvandi, Fereshte Kordehlachin, Yasin Parniani, Mohammad Mohammadpour-Aghdam, Karim Faranoush, Pooya Foroughi-Gilvaee, Mohammad Reza Abdolahad, Mohammad |
author_facet | Mokhtari Dowlatabad, Hadi Mamdouh, Amir Yousefpour, Narges Mahdavi, Reihane Zandi, Ashkan Hoseinpour, Parisa Moosavi-Kiasari, Seyed Mohammad Sadegh Abbasvandi, Fereshte Kordehlachin, Yasin Parniani, Mohammad Mohammadpour-Aghdam, Karim Faranoush, Pooya Foroughi-Gilvaee, Mohammad Reza Abdolahad, Mohammad |
author_sort | Mokhtari Dowlatabad, Hadi |
collection | PubMed |
description | A gigahertz (GHz) range antenna formed by a coaxial probe has been applied for sensing cancerous breast lesions in the scanning platform with the assistance of a suction tube. The sensor structure was a planar central layer and a metallic sheath of size of 3 cm(2) connected to a network analyzer (keySight FieldFox N9918A) with operational bandwidth up to 26.5 GHz. Cancer tumor cells have significantly higher water content (as a dipolar molecule) than normal breast cells, changing their polarization responses and dielectric losses to incoming GHz-based stimulation. Principal component analysis named S(11), related to the dispersion ratio of the input signal, is used as a parameter to identify malignant tumor cells in a mouse model (in vivo) and tumor specimens of breast cancer patients (in vitro) (both central and marginal parts). The results showed that S(11) values in the frequency range from 5 to 6 GHz were significantly higher in cancer-involved breast lesions. Histopathological analysis was the gold standard for achieving the S(11) calibration to distinguish normal from cancerous lesions. Our calibration on tumor specimens presented 82% positive predictive value (PPV), 100% negative predictive value (NPV), and 86% accuracy. Our goal is to apply this system as an in vivo non-invasive tumor margin scanner after further investigations in the future. |
format | Online Article Text |
id | pubmed-9857665 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-98576652023-01-21 High-Frequency (30 MHz–6 GHz) Breast Tissue Characterization Stabilized by Suction Force for Intraoperative Tumor Margin Assessment Mokhtari Dowlatabad, Hadi Mamdouh, Amir Yousefpour, Narges Mahdavi, Reihane Zandi, Ashkan Hoseinpour, Parisa Moosavi-Kiasari, Seyed Mohammad Sadegh Abbasvandi, Fereshte Kordehlachin, Yasin Parniani, Mohammad Mohammadpour-Aghdam, Karim Faranoush, Pooya Foroughi-Gilvaee, Mohammad Reza Abdolahad, Mohammad Diagnostics (Basel) Article A gigahertz (GHz) range antenna formed by a coaxial probe has been applied for sensing cancerous breast lesions in the scanning platform with the assistance of a suction tube. The sensor structure was a planar central layer and a metallic sheath of size of 3 cm(2) connected to a network analyzer (keySight FieldFox N9918A) with operational bandwidth up to 26.5 GHz. Cancer tumor cells have significantly higher water content (as a dipolar molecule) than normal breast cells, changing their polarization responses and dielectric losses to incoming GHz-based stimulation. Principal component analysis named S(11), related to the dispersion ratio of the input signal, is used as a parameter to identify malignant tumor cells in a mouse model (in vivo) and tumor specimens of breast cancer patients (in vitro) (both central and marginal parts). The results showed that S(11) values in the frequency range from 5 to 6 GHz were significantly higher in cancer-involved breast lesions. Histopathological analysis was the gold standard for achieving the S(11) calibration to distinguish normal from cancerous lesions. Our calibration on tumor specimens presented 82% positive predictive value (PPV), 100% negative predictive value (NPV), and 86% accuracy. Our goal is to apply this system as an in vivo non-invasive tumor margin scanner after further investigations in the future. MDPI 2023-01-04 /pmc/articles/PMC9857665/ /pubmed/36672989 http://dx.doi.org/10.3390/diagnostics13020179 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Mokhtari Dowlatabad, Hadi Mamdouh, Amir Yousefpour, Narges Mahdavi, Reihane Zandi, Ashkan Hoseinpour, Parisa Moosavi-Kiasari, Seyed Mohammad Sadegh Abbasvandi, Fereshte Kordehlachin, Yasin Parniani, Mohammad Mohammadpour-Aghdam, Karim Faranoush, Pooya Foroughi-Gilvaee, Mohammad Reza Abdolahad, Mohammad High-Frequency (30 MHz–6 GHz) Breast Tissue Characterization Stabilized by Suction Force for Intraoperative Tumor Margin Assessment |
title | High-Frequency (30 MHz–6 GHz) Breast Tissue Characterization Stabilized by Suction Force for Intraoperative Tumor Margin Assessment |
title_full | High-Frequency (30 MHz–6 GHz) Breast Tissue Characterization Stabilized by Suction Force for Intraoperative Tumor Margin Assessment |
title_fullStr | High-Frequency (30 MHz–6 GHz) Breast Tissue Characterization Stabilized by Suction Force for Intraoperative Tumor Margin Assessment |
title_full_unstemmed | High-Frequency (30 MHz–6 GHz) Breast Tissue Characterization Stabilized by Suction Force for Intraoperative Tumor Margin Assessment |
title_short | High-Frequency (30 MHz–6 GHz) Breast Tissue Characterization Stabilized by Suction Force for Intraoperative Tumor Margin Assessment |
title_sort | high-frequency (30 mhz–6 ghz) breast tissue characterization stabilized by suction force for intraoperative tumor margin assessment |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9857665/ https://www.ncbi.nlm.nih.gov/pubmed/36672989 http://dx.doi.org/10.3390/diagnostics13020179 |
work_keys_str_mv | AT mokhtaridowlatabadhadi highfrequency30mhz6ghzbreasttissuecharacterizationstabilizedbysuctionforceforintraoperativetumormarginassessment AT mamdouhamir highfrequency30mhz6ghzbreasttissuecharacterizationstabilizedbysuctionforceforintraoperativetumormarginassessment AT yousefpournarges highfrequency30mhz6ghzbreasttissuecharacterizationstabilizedbysuctionforceforintraoperativetumormarginassessment AT mahdavireihane highfrequency30mhz6ghzbreasttissuecharacterizationstabilizedbysuctionforceforintraoperativetumormarginassessment AT zandiashkan highfrequency30mhz6ghzbreasttissuecharacterizationstabilizedbysuctionforceforintraoperativetumormarginassessment AT hoseinpourparisa highfrequency30mhz6ghzbreasttissuecharacterizationstabilizedbysuctionforceforintraoperativetumormarginassessment AT moosavikiasariseyedmohammadsadegh highfrequency30mhz6ghzbreasttissuecharacterizationstabilizedbysuctionforceforintraoperativetumormarginassessment AT abbasvandifereshte highfrequency30mhz6ghzbreasttissuecharacterizationstabilizedbysuctionforceforintraoperativetumormarginassessment AT kordehlachinyasin highfrequency30mhz6ghzbreasttissuecharacterizationstabilizedbysuctionforceforintraoperativetumormarginassessment AT parnianimohammad highfrequency30mhz6ghzbreasttissuecharacterizationstabilizedbysuctionforceforintraoperativetumormarginassessment AT mohammadpouraghdamkarim highfrequency30mhz6ghzbreasttissuecharacterizationstabilizedbysuctionforceforintraoperativetumormarginassessment AT faranoushpooya highfrequency30mhz6ghzbreasttissuecharacterizationstabilizedbysuctionforceforintraoperativetumormarginassessment AT foroughigilvaeemohammadreza highfrequency30mhz6ghzbreasttissuecharacterizationstabilizedbysuctionforceforintraoperativetumormarginassessment AT abdolahadmohammad highfrequency30mhz6ghzbreasttissuecharacterizationstabilizedbysuctionforceforintraoperativetumormarginassessment |