Evaluation of Accuracy and Performance of a Novel, Fully Gantry Integrated 3D Laser System for Computed Tomography Guided Needle Placement: A Phantom Study
The purpose of this phantom study was to compare the accuracy, speed and technical performance of CT guided needle placement using a conventional technique versus a novel, gantry integrated laser guidance system for both an expert and a novice. A total of 80 needle placements were performed in an ab...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9858339/ https://www.ncbi.nlm.nih.gov/pubmed/36673092 http://dx.doi.org/10.3390/diagnostics13020282 |
_version_ | 1784874074937229312 |
---|---|
author | Weigel, Katharina Kubik-Huch, Rahel A. Baer-Beck, Matthias Canstein, Christian Kostrzewa, Michael |
author_facet | Weigel, Katharina Kubik-Huch, Rahel A. Baer-Beck, Matthias Canstein, Christian Kostrzewa, Michael |
author_sort | Weigel, Katharina |
collection | PubMed |
description | The purpose of this phantom study was to compare the accuracy, speed and technical performance of CT guided needle placement using a conventional technique versus a novel, gantry integrated laser guidance system for both an expert and a novice. A total of 80 needle placements were performed in an abdominal phantom using conventional CT guidance and a laser guidance system. Analysis of pooled results of expert and novice showed a significant reduction of time (277 vs. 204 s, p = 0.001) and of the number of needle corrections (3.28 vs. 1.58, p < 0.001) required when using laser guidance versus conventional technique. No significant improvement in absolute (3.81 vs. 3.41 mm, p = 0.213) or angular deviation (2.85 vs. 2.18°, p = 0.079) was found. With either approach, the expert was significantly faster (conventional guidance: 207 s vs. 346 s, p < 0.001; laser guidance: 144 s vs. 264 s, p < 0.001) and required fewer needle corrections (conventional guidance: 4 vs. 3, p = 0.027; laser guidance: 2 vs. 1, p = 0.001) than the novice. The laser guidance system helped both the expert and the novice to perform CT guided interventions in a phantom faster and with fewer needle corrections compared to the conventional technique, while achieving similar accuracy. |
format | Online Article Text |
id | pubmed-9858339 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-98583392023-01-21 Evaluation of Accuracy and Performance of a Novel, Fully Gantry Integrated 3D Laser System for Computed Tomography Guided Needle Placement: A Phantom Study Weigel, Katharina Kubik-Huch, Rahel A. Baer-Beck, Matthias Canstein, Christian Kostrzewa, Michael Diagnostics (Basel) Article The purpose of this phantom study was to compare the accuracy, speed and technical performance of CT guided needle placement using a conventional technique versus a novel, gantry integrated laser guidance system for both an expert and a novice. A total of 80 needle placements were performed in an abdominal phantom using conventional CT guidance and a laser guidance system. Analysis of pooled results of expert and novice showed a significant reduction of time (277 vs. 204 s, p = 0.001) and of the number of needle corrections (3.28 vs. 1.58, p < 0.001) required when using laser guidance versus conventional technique. No significant improvement in absolute (3.81 vs. 3.41 mm, p = 0.213) or angular deviation (2.85 vs. 2.18°, p = 0.079) was found. With either approach, the expert was significantly faster (conventional guidance: 207 s vs. 346 s, p < 0.001; laser guidance: 144 s vs. 264 s, p < 0.001) and required fewer needle corrections (conventional guidance: 4 vs. 3, p = 0.027; laser guidance: 2 vs. 1, p = 0.001) than the novice. The laser guidance system helped both the expert and the novice to perform CT guided interventions in a phantom faster and with fewer needle corrections compared to the conventional technique, while achieving similar accuracy. MDPI 2023-01-12 /pmc/articles/PMC9858339/ /pubmed/36673092 http://dx.doi.org/10.3390/diagnostics13020282 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Weigel, Katharina Kubik-Huch, Rahel A. Baer-Beck, Matthias Canstein, Christian Kostrzewa, Michael Evaluation of Accuracy and Performance of a Novel, Fully Gantry Integrated 3D Laser System for Computed Tomography Guided Needle Placement: A Phantom Study |
title | Evaluation of Accuracy and Performance of a Novel, Fully Gantry Integrated 3D Laser System for Computed Tomography Guided Needle Placement: A Phantom Study |
title_full | Evaluation of Accuracy and Performance of a Novel, Fully Gantry Integrated 3D Laser System for Computed Tomography Guided Needle Placement: A Phantom Study |
title_fullStr | Evaluation of Accuracy and Performance of a Novel, Fully Gantry Integrated 3D Laser System for Computed Tomography Guided Needle Placement: A Phantom Study |
title_full_unstemmed | Evaluation of Accuracy and Performance of a Novel, Fully Gantry Integrated 3D Laser System for Computed Tomography Guided Needle Placement: A Phantom Study |
title_short | Evaluation of Accuracy and Performance of a Novel, Fully Gantry Integrated 3D Laser System for Computed Tomography Guided Needle Placement: A Phantom Study |
title_sort | evaluation of accuracy and performance of a novel, fully gantry integrated 3d laser system for computed tomography guided needle placement: a phantom study |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9858339/ https://www.ncbi.nlm.nih.gov/pubmed/36673092 http://dx.doi.org/10.3390/diagnostics13020282 |
work_keys_str_mv | AT weigelkatharina evaluationofaccuracyandperformanceofanovelfullygantryintegrated3dlasersystemforcomputedtomographyguidedneedleplacementaphantomstudy AT kubikhuchrahela evaluationofaccuracyandperformanceofanovelfullygantryintegrated3dlasersystemforcomputedtomographyguidedneedleplacementaphantomstudy AT baerbeckmatthias evaluationofaccuracyandperformanceofanovelfullygantryintegrated3dlasersystemforcomputedtomographyguidedneedleplacementaphantomstudy AT cansteinchristian evaluationofaccuracyandperformanceofanovelfullygantryintegrated3dlasersystemforcomputedtomographyguidedneedleplacementaphantomstudy AT kostrzewamichael evaluationofaccuracyandperformanceofanovelfullygantryintegrated3dlasersystemforcomputedtomographyguidedneedleplacementaphantomstudy |