Cargando…

Demonstration of Accuracy and Feasibility of Remotely Delivered Oximetry: A Blinded, Controlled, Real-World Study of Regional/Rural Children with Obstructive Sleep Apnoea

Objectives: Evaluate diagnostic accuracy and feasibility of a mail-out home oximetry kit. Design: Patients were referred for both the tertiary/quaternary-centre hospital-delivered oximetry (HDO) and for the mail-out remotely-delivered oximetry (RDO). Quantitative and qualitative data were collected....

Descripción completa

Detalles Bibliográficos
Autores principales: Begley, Ryan, Kanagasingam, Yogesan, Chan, Chun, Perera, Chandrashan, Vandeleur, Moya, Paddle, Paul
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9859066/
https://www.ncbi.nlm.nih.gov/pubmed/36673646
http://dx.doi.org/10.3390/healthcare11020278
_version_ 1784874262866165760
author Begley, Ryan
Kanagasingam, Yogesan
Chan, Chun
Perera, Chandrashan
Vandeleur, Moya
Paddle, Paul
author_facet Begley, Ryan
Kanagasingam, Yogesan
Chan, Chun
Perera, Chandrashan
Vandeleur, Moya
Paddle, Paul
author_sort Begley, Ryan
collection PubMed
description Objectives: Evaluate diagnostic accuracy and feasibility of a mail-out home oximetry kit. Design: Patients were referred for both the tertiary/quaternary-centre hospital-delivered oximetry (HDO) and for the mail-out remotely-delivered oximetry (RDO). Quantitative and qualitative data were collected. The COVID-19 pandemic began during this study; therefore, necessary methodological adjustments were implemented. Setting: Patients were first evaluated in Swan Hill, Victoria. RDO kits were sent to home addresses. For the HDO, patients travelled to the Melbourne city area, received the kit, stayed overnight, and returned the kit the following morning. Participants: All consecutive paediatric patients (aged 2–18), diagnosed by a specialist in Swan Hill with obstructive sleep apnoea (OSA) on history/examination, and booked for tonsillectomy +/− adenoidectomy, were recruited. Main outcome measures: Diagnostic accuracy (i.e., comparison of RDO to HDO results) and test delivery time (i.e., days from consent signature to oximetry delivery) were recorded. Patient travel distances for HDO collection were calculated using home/delivery address postcodes and Google(®) Maps data. Qualitative data were collected with two digital follow-up surveys. Results: All 32 patients that had both the HDO and RDO had identical oximetry results. The HDO mean delivery time was 87.7 days, while the RDO mean delivery time was 23.6 days (p value: <0.001). Qualitatively, 3/28 preferred the HDO, while 25/28 preferred the RDO (n = 28). Conclusions: The remote option is as accurate as the hospital option, strongly preferred by patients, more rapidly completed, and also an ideal investigation delivery method during certain emergencies, such as the COVID-19 pandemic.
format Online
Article
Text
id pubmed-9859066
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-98590662023-01-21 Demonstration of Accuracy and Feasibility of Remotely Delivered Oximetry: A Blinded, Controlled, Real-World Study of Regional/Rural Children with Obstructive Sleep Apnoea Begley, Ryan Kanagasingam, Yogesan Chan, Chun Perera, Chandrashan Vandeleur, Moya Paddle, Paul Healthcare (Basel) Article Objectives: Evaluate diagnostic accuracy and feasibility of a mail-out home oximetry kit. Design: Patients were referred for both the tertiary/quaternary-centre hospital-delivered oximetry (HDO) and for the mail-out remotely-delivered oximetry (RDO). Quantitative and qualitative data were collected. The COVID-19 pandemic began during this study; therefore, necessary methodological adjustments were implemented. Setting: Patients were first evaluated in Swan Hill, Victoria. RDO kits were sent to home addresses. For the HDO, patients travelled to the Melbourne city area, received the kit, stayed overnight, and returned the kit the following morning. Participants: All consecutive paediatric patients (aged 2–18), diagnosed by a specialist in Swan Hill with obstructive sleep apnoea (OSA) on history/examination, and booked for tonsillectomy +/− adenoidectomy, were recruited. Main outcome measures: Diagnostic accuracy (i.e., comparison of RDO to HDO results) and test delivery time (i.e., days from consent signature to oximetry delivery) were recorded. Patient travel distances for HDO collection were calculated using home/delivery address postcodes and Google(®) Maps data. Qualitative data were collected with two digital follow-up surveys. Results: All 32 patients that had both the HDO and RDO had identical oximetry results. The HDO mean delivery time was 87.7 days, while the RDO mean delivery time was 23.6 days (p value: <0.001). Qualitatively, 3/28 preferred the HDO, while 25/28 preferred the RDO (n = 28). Conclusions: The remote option is as accurate as the hospital option, strongly preferred by patients, more rapidly completed, and also an ideal investigation delivery method during certain emergencies, such as the COVID-19 pandemic. MDPI 2023-01-16 /pmc/articles/PMC9859066/ /pubmed/36673646 http://dx.doi.org/10.3390/healthcare11020278 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Begley, Ryan
Kanagasingam, Yogesan
Chan, Chun
Perera, Chandrashan
Vandeleur, Moya
Paddle, Paul
Demonstration of Accuracy and Feasibility of Remotely Delivered Oximetry: A Blinded, Controlled, Real-World Study of Regional/Rural Children with Obstructive Sleep Apnoea
title Demonstration of Accuracy and Feasibility of Remotely Delivered Oximetry: A Blinded, Controlled, Real-World Study of Regional/Rural Children with Obstructive Sleep Apnoea
title_full Demonstration of Accuracy and Feasibility of Remotely Delivered Oximetry: A Blinded, Controlled, Real-World Study of Regional/Rural Children with Obstructive Sleep Apnoea
title_fullStr Demonstration of Accuracy and Feasibility of Remotely Delivered Oximetry: A Blinded, Controlled, Real-World Study of Regional/Rural Children with Obstructive Sleep Apnoea
title_full_unstemmed Demonstration of Accuracy and Feasibility of Remotely Delivered Oximetry: A Blinded, Controlled, Real-World Study of Regional/Rural Children with Obstructive Sleep Apnoea
title_short Demonstration of Accuracy and Feasibility of Remotely Delivered Oximetry: A Blinded, Controlled, Real-World Study of Regional/Rural Children with Obstructive Sleep Apnoea
title_sort demonstration of accuracy and feasibility of remotely delivered oximetry: a blinded, controlled, real-world study of regional/rural children with obstructive sleep apnoea
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9859066/
https://www.ncbi.nlm.nih.gov/pubmed/36673646
http://dx.doi.org/10.3390/healthcare11020278
work_keys_str_mv AT begleyryan demonstrationofaccuracyandfeasibilityofremotelydeliveredoximetryablindedcontrolledrealworldstudyofregionalruralchildrenwithobstructivesleepapnoea
AT kanagasingamyogesan demonstrationofaccuracyandfeasibilityofremotelydeliveredoximetryablindedcontrolledrealworldstudyofregionalruralchildrenwithobstructivesleepapnoea
AT chanchun demonstrationofaccuracyandfeasibilityofremotelydeliveredoximetryablindedcontrolledrealworldstudyofregionalruralchildrenwithobstructivesleepapnoea
AT pererachandrashan demonstrationofaccuracyandfeasibilityofremotelydeliveredoximetryablindedcontrolledrealworldstudyofregionalruralchildrenwithobstructivesleepapnoea
AT vandeleurmoya demonstrationofaccuracyandfeasibilityofremotelydeliveredoximetryablindedcontrolledrealworldstudyofregionalruralchildrenwithobstructivesleepapnoea
AT paddlepaul demonstrationofaccuracyandfeasibilityofremotelydeliveredoximetryablindedcontrolledrealworldstudyofregionalruralchildrenwithobstructivesleepapnoea