Cargando…

Test–Retest Reliability of the Functional Electromechanical Dynamometer for Squat Exercise

Background: the main objective of this study was to evaluate the test-retest reliability of two different functional electromechanical dynamometry (FEMD)-controlled squat training protocols. Methods: twenty-eight healthy young adults volunteered to participate in this study. They attended the labora...

Descripción completa

Detalles Bibliográficos
Autores principales: del-Cuerpo, Indya, Jerez-Mayorga, Daniel, Delgado-Floody, Pedro, Morenas-Aguilar, María Dolores, Chirosa-Ríos, Luis Javier
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9859296/
https://www.ncbi.nlm.nih.gov/pubmed/36674047
http://dx.doi.org/10.3390/ijerph20021289
_version_ 1784874319778676736
author del-Cuerpo, Indya
Jerez-Mayorga, Daniel
Delgado-Floody, Pedro
Morenas-Aguilar, María Dolores
Chirosa-Ríos, Luis Javier
author_facet del-Cuerpo, Indya
Jerez-Mayorga, Daniel
Delgado-Floody, Pedro
Morenas-Aguilar, María Dolores
Chirosa-Ríos, Luis Javier
author_sort del-Cuerpo, Indya
collection PubMed
description Background: the main objective of this study was to evaluate the test-retest reliability of two different functional electromechanical dynamometry (FEMD)-controlled squat training protocols. Methods: twenty-eight healthy young adults volunteered to participate in this study. They attended the laboratory on four different days and performed four sessions: two of three sets of 12 repetitions at 75% 1RM and two of three sets of 30 repetitions at 50% 1RM. The range of movement (ROM), mean dynamic strength (MDS), peak dynamic strength (PDS), mean velocity (MV), peak velocity (PV), mean potency (MP), peak potency (PP), work (W), and impulse (I) were recorded. To evaluate the reliability of FEMD, the intraclass correlation coefficient (ICC), standard error of measurement (SEM), and coefficient of variation (CV) were obtained. Results: reliability was very high for ROM (CV: 3.72%, ICC: 0.95), MDS (CV: 1.09%, ICC: 1.00), PDS (CV: 1.97%, ICC: 1.00), and W (CV: 4.69%, ICC: 1.00) conditions at 50% 1RM and for ROM (CV: 3.90%, ICC: 0.95), MDS (CV: 0.52, ICC: 1.00), PDS (CV: 1.49%, ICC: 0.98), and W (CV: 4.14%, ICC: 1.00) conditions at 75% 1RM and high for the rest of variables at 50 and 75% 1RM. Conclusions: this study demonstrates that FEMD is a reliable instrument to measure ROM, MDS, PDS, MV, PV, PV, MP, MP, W, and I during both squat protocols (50 and 75% 1RM) in healthy young adults.
format Online
Article
Text
id pubmed-9859296
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-98592962023-01-21 Test–Retest Reliability of the Functional Electromechanical Dynamometer for Squat Exercise del-Cuerpo, Indya Jerez-Mayorga, Daniel Delgado-Floody, Pedro Morenas-Aguilar, María Dolores Chirosa-Ríos, Luis Javier Int J Environ Res Public Health Article Background: the main objective of this study was to evaluate the test-retest reliability of two different functional electromechanical dynamometry (FEMD)-controlled squat training protocols. Methods: twenty-eight healthy young adults volunteered to participate in this study. They attended the laboratory on four different days and performed four sessions: two of three sets of 12 repetitions at 75% 1RM and two of three sets of 30 repetitions at 50% 1RM. The range of movement (ROM), mean dynamic strength (MDS), peak dynamic strength (PDS), mean velocity (MV), peak velocity (PV), mean potency (MP), peak potency (PP), work (W), and impulse (I) were recorded. To evaluate the reliability of FEMD, the intraclass correlation coefficient (ICC), standard error of measurement (SEM), and coefficient of variation (CV) were obtained. Results: reliability was very high for ROM (CV: 3.72%, ICC: 0.95), MDS (CV: 1.09%, ICC: 1.00), PDS (CV: 1.97%, ICC: 1.00), and W (CV: 4.69%, ICC: 1.00) conditions at 50% 1RM and for ROM (CV: 3.90%, ICC: 0.95), MDS (CV: 0.52, ICC: 1.00), PDS (CV: 1.49%, ICC: 0.98), and W (CV: 4.14%, ICC: 1.00) conditions at 75% 1RM and high for the rest of variables at 50 and 75% 1RM. Conclusions: this study demonstrates that FEMD is a reliable instrument to measure ROM, MDS, PDS, MV, PV, PV, MP, MP, W, and I during both squat protocols (50 and 75% 1RM) in healthy young adults. MDPI 2023-01-11 /pmc/articles/PMC9859296/ /pubmed/36674047 http://dx.doi.org/10.3390/ijerph20021289 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
del-Cuerpo, Indya
Jerez-Mayorga, Daniel
Delgado-Floody, Pedro
Morenas-Aguilar, María Dolores
Chirosa-Ríos, Luis Javier
Test–Retest Reliability of the Functional Electromechanical Dynamometer for Squat Exercise
title Test–Retest Reliability of the Functional Electromechanical Dynamometer for Squat Exercise
title_full Test–Retest Reliability of the Functional Electromechanical Dynamometer for Squat Exercise
title_fullStr Test–Retest Reliability of the Functional Electromechanical Dynamometer for Squat Exercise
title_full_unstemmed Test–Retest Reliability of the Functional Electromechanical Dynamometer for Squat Exercise
title_short Test–Retest Reliability of the Functional Electromechanical Dynamometer for Squat Exercise
title_sort test–retest reliability of the functional electromechanical dynamometer for squat exercise
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9859296/
https://www.ncbi.nlm.nih.gov/pubmed/36674047
http://dx.doi.org/10.3390/ijerph20021289
work_keys_str_mv AT delcuerpoindya testretestreliabilityofthefunctionalelectromechanicaldynamometerforsquatexercise
AT jerezmayorgadaniel testretestreliabilityofthefunctionalelectromechanicaldynamometerforsquatexercise
AT delgadofloodypedro testretestreliabilityofthefunctionalelectromechanicaldynamometerforsquatexercise
AT morenasaguilarmariadolores testretestreliabilityofthefunctionalelectromechanicaldynamometerforsquatexercise
AT chirosariosluisjavier testretestreliabilityofthefunctionalelectromechanicaldynamometerforsquatexercise