Cargando…

Conventional ultrasonography and elastosonography in diagnosis of malignant thyroid nodules: A systematic review and meta-analysis

PURPOSE: To evaluate the diagnostic value of conventional ultrasound and elastosonography in malignant thyroid nodules by meta-analysis. METHODS: The literature included in the Cochrane Library, PubMed, and Embase were searched by using “elastosonography, ultrasonography, thyroid nodules” as the key...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Dian, Wang, Xiao-Na, Jiang, Li, Yu, Chun-Xia, Chen, Yue-Nan, Yu, Xue-Juan, Pan, Mei-Fang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9859672/
https://www.ncbi.nlm.nih.gov/pubmed/36686488
http://dx.doi.org/10.3389/fendo.2022.1082881
_version_ 1784874412437143552
author Zhang, Dian
Wang, Xiao-Na
Jiang, Li
Yu, Chun-Xia
Chen, Yue-Nan
Yu, Xue-Juan
Pan, Mei-Fang
author_facet Zhang, Dian
Wang, Xiao-Na
Jiang, Li
Yu, Chun-Xia
Chen, Yue-Nan
Yu, Xue-Juan
Pan, Mei-Fang
author_sort Zhang, Dian
collection PubMed
description PURPOSE: To evaluate the diagnostic value of conventional ultrasound and elastosonography in malignant thyroid nodules by meta-analysis. METHODS: The literature included in the Cochrane Library, PubMed, and Embase were searched by using “elastosonography, ultrasonography, thyroid nodules” as the keywords. The clinical studies using elastosonography and conventional ultrasound to diagnose thyroid nodules were selected, and histopathology of thyroid nodules was used as reference standards. The quality evaluation and heterogeneity test were performed on the literature that met the requirements, the combined specificity and sensitivity were pooled, and a comprehensive ROC curve analysis was performed. The Quality Assessment of Diagnostic Accuracy Studies (QUADAS) tool was utilized to evaluate the quality of each included study. Meta-DiSc version 1.4, StataSE 12 and Review Manager 5.4 were used. RESULTS: A total of nine studies assessed 3066 thyroid nodules (2043 benign and 1023 malignant). The pooled sensitivity, specificity, PLR, NLR, and DOR of conventional ultrasound for the diagnose of malignant thyroid nodules were 0.833 (95% CI 0.809-0.855), 0.818 (95% CI 0.801-0.835), 4.85 (95% CI 4.36-5.39), 0.20 (95% CI 0.17-0.23), and 29.38 (95% CI 23.28-37.08), respectively, with an AUC of 0.9068. Also, the pooled sensitivity, specificity, PLR, NLR, and DOR of elastosonography were 0.774 (95% CI 0.741-0.804), 0.737 (95% CI 0.715-0.758), 3.14(95% CI 2.85-3.47), 0.29 (95% CI 0.25-0.34), and 9.35 (95% CI 7.63-11.46), respectively, with an AUC of 0.8801. Three studies provided data regarding the conventional ultrasound and elastosonography. The pooled sensitivity, specificity, PLR, NLR, DOR, and AUC were 0.902 (95% CI 0.870-0.928), 0.649 (95% CI 0.616-0.681), 2.72 (95% CI 2.46-3.00), 0.14 (95% CI 0.11-0.19), 25.51 (95%CI 17.11–38.03), and 0.9294. CONCLUSION: The existing evidence shows that elastosonography cannot completely replace conventional ultrasound in the diagnosis of malignant thyroid nodules, and the combination of elastosonography and conventional ultrasound gives a better diagnostic precision. SYSTEMATIC REVIEW REGISTRATION: www.crd.york.ac.uk, identifier PROSPERO CRD42022375808.
format Online
Article
Text
id pubmed-9859672
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-98596722023-01-21 Conventional ultrasonography and elastosonography in diagnosis of malignant thyroid nodules: A systematic review and meta-analysis Zhang, Dian Wang, Xiao-Na Jiang, Li Yu, Chun-Xia Chen, Yue-Nan Yu, Xue-Juan Pan, Mei-Fang Front Endocrinol (Lausanne) Endocrinology PURPOSE: To evaluate the diagnostic value of conventional ultrasound and elastosonography in malignant thyroid nodules by meta-analysis. METHODS: The literature included in the Cochrane Library, PubMed, and Embase were searched by using “elastosonography, ultrasonography, thyroid nodules” as the keywords. The clinical studies using elastosonography and conventional ultrasound to diagnose thyroid nodules were selected, and histopathology of thyroid nodules was used as reference standards. The quality evaluation and heterogeneity test were performed on the literature that met the requirements, the combined specificity and sensitivity were pooled, and a comprehensive ROC curve analysis was performed. The Quality Assessment of Diagnostic Accuracy Studies (QUADAS) tool was utilized to evaluate the quality of each included study. Meta-DiSc version 1.4, StataSE 12 and Review Manager 5.4 were used. RESULTS: A total of nine studies assessed 3066 thyroid nodules (2043 benign and 1023 malignant). The pooled sensitivity, specificity, PLR, NLR, and DOR of conventional ultrasound for the diagnose of malignant thyroid nodules were 0.833 (95% CI 0.809-0.855), 0.818 (95% CI 0.801-0.835), 4.85 (95% CI 4.36-5.39), 0.20 (95% CI 0.17-0.23), and 29.38 (95% CI 23.28-37.08), respectively, with an AUC of 0.9068. Also, the pooled sensitivity, specificity, PLR, NLR, and DOR of elastosonography were 0.774 (95% CI 0.741-0.804), 0.737 (95% CI 0.715-0.758), 3.14(95% CI 2.85-3.47), 0.29 (95% CI 0.25-0.34), and 9.35 (95% CI 7.63-11.46), respectively, with an AUC of 0.8801. Three studies provided data regarding the conventional ultrasound and elastosonography. The pooled sensitivity, specificity, PLR, NLR, DOR, and AUC were 0.902 (95% CI 0.870-0.928), 0.649 (95% CI 0.616-0.681), 2.72 (95% CI 2.46-3.00), 0.14 (95% CI 0.11-0.19), 25.51 (95%CI 17.11–38.03), and 0.9294. CONCLUSION: The existing evidence shows that elastosonography cannot completely replace conventional ultrasound in the diagnosis of malignant thyroid nodules, and the combination of elastosonography and conventional ultrasound gives a better diagnostic precision. SYSTEMATIC REVIEW REGISTRATION: www.crd.york.ac.uk, identifier PROSPERO CRD42022375808. Frontiers Media S.A. 2023-01-06 /pmc/articles/PMC9859672/ /pubmed/36686488 http://dx.doi.org/10.3389/fendo.2022.1082881 Text en Copyright © 2023 Zhang, Wang, Jiang, Yu, Chen, Yu and Pan https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Endocrinology
Zhang, Dian
Wang, Xiao-Na
Jiang, Li
Yu, Chun-Xia
Chen, Yue-Nan
Yu, Xue-Juan
Pan, Mei-Fang
Conventional ultrasonography and elastosonography in diagnosis of malignant thyroid nodules: A systematic review and meta-analysis
title Conventional ultrasonography and elastosonography in diagnosis of malignant thyroid nodules: A systematic review and meta-analysis
title_full Conventional ultrasonography and elastosonography in diagnosis of malignant thyroid nodules: A systematic review and meta-analysis
title_fullStr Conventional ultrasonography and elastosonography in diagnosis of malignant thyroid nodules: A systematic review and meta-analysis
title_full_unstemmed Conventional ultrasonography and elastosonography in diagnosis of malignant thyroid nodules: A systematic review and meta-analysis
title_short Conventional ultrasonography and elastosonography in diagnosis of malignant thyroid nodules: A systematic review and meta-analysis
title_sort conventional ultrasonography and elastosonography in diagnosis of malignant thyroid nodules: a systematic review and meta-analysis
topic Endocrinology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9859672/
https://www.ncbi.nlm.nih.gov/pubmed/36686488
http://dx.doi.org/10.3389/fendo.2022.1082881
work_keys_str_mv AT zhangdian conventionalultrasonographyandelastosonographyindiagnosisofmalignantthyroidnodulesasystematicreviewandmetaanalysis
AT wangxiaona conventionalultrasonographyandelastosonographyindiagnosisofmalignantthyroidnodulesasystematicreviewandmetaanalysis
AT jiangli conventionalultrasonographyandelastosonographyindiagnosisofmalignantthyroidnodulesasystematicreviewandmetaanalysis
AT yuchunxia conventionalultrasonographyandelastosonographyindiagnosisofmalignantthyroidnodulesasystematicreviewandmetaanalysis
AT chenyuenan conventionalultrasonographyandelastosonographyindiagnosisofmalignantthyroidnodulesasystematicreviewandmetaanalysis
AT yuxuejuan conventionalultrasonographyandelastosonographyindiagnosisofmalignantthyroidnodulesasystematicreviewandmetaanalysis
AT panmeifang conventionalultrasonographyandelastosonographyindiagnosisofmalignantthyroidnodulesasystematicreviewandmetaanalysis