Cargando…
Inter-Observer Variability in MR-Based Target Volume Delineation of Uveal Melanoma
PURPOSE: Several efforts are being undertaken toward MRI-based treatment planning for ocular proton therapy for uveal melanoma (UM). The interobserver variability of the gross target volume (GTV) on magnetic resonance imaging (MRI) is one of the important parameters to design safety margins for a re...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9860418/ https://www.ncbi.nlm.nih.gov/pubmed/36691449 http://dx.doi.org/10.1016/j.adro.2022.101149 |
_version_ | 1784874578017779712 |
---|---|
author | Jaarsma-Coes, Myriam G. Klaassen, Lisa Verbist, Berit M. Vu, T.H. Khanh Klaver, Yvonne L.B. Rodrigues, Myra F. Nabarro, Claire Luyten, Gregorius P.M. Rasch, Coen R.N. van Herk, Marcel Beenakker, Jan-Willem M. |
author_facet | Jaarsma-Coes, Myriam G. Klaassen, Lisa Verbist, Berit M. Vu, T.H. Khanh Klaver, Yvonne L.B. Rodrigues, Myra F. Nabarro, Claire Luyten, Gregorius P.M. Rasch, Coen R.N. van Herk, Marcel Beenakker, Jan-Willem M. |
author_sort | Jaarsma-Coes, Myriam G. |
collection | PubMed |
description | PURPOSE: Several efforts are being undertaken toward MRI-based treatment planning for ocular proton therapy for uveal melanoma (UM). The interobserver variability of the gross target volume (GTV) on magnetic resonance imaging (MRI) is one of the important parameters to design safety margins for a reliable treatment. Therefore, this study assessed the interobserver variation in GTV delineation of UM on MRI. METHODS AND MATERIALS: Six observers delineated the GTV in 10 different patients using the Big Brother contouring software. Patients were scanned at 3T MRI with a surface coil, and tumors were delineated separately on contrast enhanced 3DT1 (T1gd) and 3DT2-weighted scans with an isotropic acquisition resolution of 0.8 mm. Volume difference and overall local variation (median standard deviation of the distance between the delineated contours and the median contour) were analyzed for each GTV. Additionally, the local variation was analyzed for 4 interfaces: sclera, vitreous, retinal detachment, and tumor-choroid interface. RESULTS: The average GTV was significantly larger on T1gd (0.57cm(3)) compared with T2 (0.51cm(3), P = .01). A not significant higher interobserver variation was found on T1gd (0.41 mm) compared with T2 (0.35 mm). The largest variations were found at the tumor-choroid interface due to peritumoral enhancement (T1gd, 0.62 mm; T2, 0.52 mm). As a result, a larger part of this tumor-choroid interface appeared to be included on T1gd-based GTVs compared with T2, explaining the smaller volumes on T2. CONCLUSIONS: The interobserver variation of 0.4 mm on MRI are low with respect to the voxel size of 0.8 mm, enabling small treatment margins. We recommend delineation based on the T1gd-weighted scans, as choroidal tumor extensions might be missed. |
format | Online Article Text |
id | pubmed-9860418 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-98604182023-01-22 Inter-Observer Variability in MR-Based Target Volume Delineation of Uveal Melanoma Jaarsma-Coes, Myriam G. Klaassen, Lisa Verbist, Berit M. Vu, T.H. Khanh Klaver, Yvonne L.B. Rodrigues, Myra F. Nabarro, Claire Luyten, Gregorius P.M. Rasch, Coen R.N. van Herk, Marcel Beenakker, Jan-Willem M. Adv Radiat Oncol Scientific Article PURPOSE: Several efforts are being undertaken toward MRI-based treatment planning for ocular proton therapy for uveal melanoma (UM). The interobserver variability of the gross target volume (GTV) on magnetic resonance imaging (MRI) is one of the important parameters to design safety margins for a reliable treatment. Therefore, this study assessed the interobserver variation in GTV delineation of UM on MRI. METHODS AND MATERIALS: Six observers delineated the GTV in 10 different patients using the Big Brother contouring software. Patients were scanned at 3T MRI with a surface coil, and tumors were delineated separately on contrast enhanced 3DT1 (T1gd) and 3DT2-weighted scans with an isotropic acquisition resolution of 0.8 mm. Volume difference and overall local variation (median standard deviation of the distance between the delineated contours and the median contour) were analyzed for each GTV. Additionally, the local variation was analyzed for 4 interfaces: sclera, vitreous, retinal detachment, and tumor-choroid interface. RESULTS: The average GTV was significantly larger on T1gd (0.57cm(3)) compared with T2 (0.51cm(3), P = .01). A not significant higher interobserver variation was found on T1gd (0.41 mm) compared with T2 (0.35 mm). The largest variations were found at the tumor-choroid interface due to peritumoral enhancement (T1gd, 0.62 mm; T2, 0.52 mm). As a result, a larger part of this tumor-choroid interface appeared to be included on T1gd-based GTVs compared with T2, explaining the smaller volumes on T2. CONCLUSIONS: The interobserver variation of 0.4 mm on MRI are low with respect to the voxel size of 0.8 mm, enabling small treatment margins. We recommend delineation based on the T1gd-weighted scans, as choroidal tumor extensions might be missed. Elsevier 2022-12-24 /pmc/articles/PMC9860418/ /pubmed/36691449 http://dx.doi.org/10.1016/j.adro.2022.101149 Text en © 2022 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Scientific Article Jaarsma-Coes, Myriam G. Klaassen, Lisa Verbist, Berit M. Vu, T.H. Khanh Klaver, Yvonne L.B. Rodrigues, Myra F. Nabarro, Claire Luyten, Gregorius P.M. Rasch, Coen R.N. van Herk, Marcel Beenakker, Jan-Willem M. Inter-Observer Variability in MR-Based Target Volume Delineation of Uveal Melanoma |
title | Inter-Observer Variability in MR-Based Target Volume Delineation of Uveal Melanoma |
title_full | Inter-Observer Variability in MR-Based Target Volume Delineation of Uveal Melanoma |
title_fullStr | Inter-Observer Variability in MR-Based Target Volume Delineation of Uveal Melanoma |
title_full_unstemmed | Inter-Observer Variability in MR-Based Target Volume Delineation of Uveal Melanoma |
title_short | Inter-Observer Variability in MR-Based Target Volume Delineation of Uveal Melanoma |
title_sort | inter-observer variability in mr-based target volume delineation of uveal melanoma |
topic | Scientific Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9860418/ https://www.ncbi.nlm.nih.gov/pubmed/36691449 http://dx.doi.org/10.1016/j.adro.2022.101149 |
work_keys_str_mv | AT jaarsmacoesmyriamg interobservervariabilityinmrbasedtargetvolumedelineationofuvealmelanoma AT klaassenlisa interobservervariabilityinmrbasedtargetvolumedelineationofuvealmelanoma AT verbistberitm interobservervariabilityinmrbasedtargetvolumedelineationofuvealmelanoma AT vuthkhanh interobservervariabilityinmrbasedtargetvolumedelineationofuvealmelanoma AT klaveryvonnelb interobservervariabilityinmrbasedtargetvolumedelineationofuvealmelanoma AT rodriguesmyraf interobservervariabilityinmrbasedtargetvolumedelineationofuvealmelanoma AT nabarroclaire interobservervariabilityinmrbasedtargetvolumedelineationofuvealmelanoma AT luytengregoriuspm interobservervariabilityinmrbasedtargetvolumedelineationofuvealmelanoma AT raschcoenrn interobservervariabilityinmrbasedtargetvolumedelineationofuvealmelanoma AT vanherkmarcel interobservervariabilityinmrbasedtargetvolumedelineationofuvealmelanoma AT beenakkerjanwillemm interobservervariabilityinmrbasedtargetvolumedelineationofuvealmelanoma |