Cargando…

Inter-Observer Variability in MR-Based Target Volume Delineation of Uveal Melanoma

PURPOSE: Several efforts are being undertaken toward MRI-based treatment planning for ocular proton therapy for uveal melanoma (UM). The interobserver variability of the gross target volume (GTV) on magnetic resonance imaging (MRI) is one of the important parameters to design safety margins for a re...

Descripción completa

Detalles Bibliográficos
Autores principales: Jaarsma-Coes, Myriam G., Klaassen, Lisa, Verbist, Berit M., Vu, T.H. Khanh, Klaver, Yvonne L.B., Rodrigues, Myra F., Nabarro, Claire, Luyten, Gregorius P.M., Rasch, Coen R.N., van Herk, Marcel, Beenakker, Jan-Willem M.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9860418/
https://www.ncbi.nlm.nih.gov/pubmed/36691449
http://dx.doi.org/10.1016/j.adro.2022.101149
_version_ 1784874578017779712
author Jaarsma-Coes, Myriam G.
Klaassen, Lisa
Verbist, Berit M.
Vu, T.H. Khanh
Klaver, Yvonne L.B.
Rodrigues, Myra F.
Nabarro, Claire
Luyten, Gregorius P.M.
Rasch, Coen R.N.
van Herk, Marcel
Beenakker, Jan-Willem M.
author_facet Jaarsma-Coes, Myriam G.
Klaassen, Lisa
Verbist, Berit M.
Vu, T.H. Khanh
Klaver, Yvonne L.B.
Rodrigues, Myra F.
Nabarro, Claire
Luyten, Gregorius P.M.
Rasch, Coen R.N.
van Herk, Marcel
Beenakker, Jan-Willem M.
author_sort Jaarsma-Coes, Myriam G.
collection PubMed
description PURPOSE: Several efforts are being undertaken toward MRI-based treatment planning for ocular proton therapy for uveal melanoma (UM). The interobserver variability of the gross target volume (GTV) on magnetic resonance imaging (MRI) is one of the important parameters to design safety margins for a reliable treatment. Therefore, this study assessed the interobserver variation in GTV delineation of UM on MRI. METHODS AND MATERIALS: Six observers delineated the GTV in 10 different patients using the Big Brother contouring software. Patients were scanned at 3T MRI with a surface coil, and tumors were delineated separately on contrast enhanced 3DT1 (T1gd) and 3DT2-weighted scans with an isotropic acquisition resolution of 0.8 mm. Volume difference and overall local variation (median standard deviation of the distance between the delineated contours and the median contour) were analyzed for each GTV. Additionally, the local variation was analyzed for 4 interfaces: sclera, vitreous, retinal detachment, and tumor-choroid interface. RESULTS: The average GTV was significantly larger on T1gd (0.57cm(3)) compared with T2 (0.51cm(3), P = .01). A not significant higher interobserver variation was found on T1gd (0.41 mm) compared with T2 (0.35 mm). The largest variations were found at the tumor-choroid interface due to peritumoral enhancement (T1gd, 0.62 mm; T2, 0.52 mm). As a result, a larger part of this tumor-choroid interface appeared to be included on T1gd-based GTVs compared with T2, explaining the smaller volumes on T2. CONCLUSIONS: The interobserver variation of 0.4 mm on MRI are low with respect to the voxel size of 0.8 mm, enabling small treatment margins. We recommend delineation based on the T1gd-weighted scans, as choroidal tumor extensions might be missed.
format Online
Article
Text
id pubmed-9860418
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-98604182023-01-22 Inter-Observer Variability in MR-Based Target Volume Delineation of Uveal Melanoma Jaarsma-Coes, Myriam G. Klaassen, Lisa Verbist, Berit M. Vu, T.H. Khanh Klaver, Yvonne L.B. Rodrigues, Myra F. Nabarro, Claire Luyten, Gregorius P.M. Rasch, Coen R.N. van Herk, Marcel Beenakker, Jan-Willem M. Adv Radiat Oncol Scientific Article PURPOSE: Several efforts are being undertaken toward MRI-based treatment planning for ocular proton therapy for uveal melanoma (UM). The interobserver variability of the gross target volume (GTV) on magnetic resonance imaging (MRI) is one of the important parameters to design safety margins for a reliable treatment. Therefore, this study assessed the interobserver variation in GTV delineation of UM on MRI. METHODS AND MATERIALS: Six observers delineated the GTV in 10 different patients using the Big Brother contouring software. Patients were scanned at 3T MRI with a surface coil, and tumors were delineated separately on contrast enhanced 3DT1 (T1gd) and 3DT2-weighted scans with an isotropic acquisition resolution of 0.8 mm. Volume difference and overall local variation (median standard deviation of the distance between the delineated contours and the median contour) were analyzed for each GTV. Additionally, the local variation was analyzed for 4 interfaces: sclera, vitreous, retinal detachment, and tumor-choroid interface. RESULTS: The average GTV was significantly larger on T1gd (0.57cm(3)) compared with T2 (0.51cm(3), P = .01). A not significant higher interobserver variation was found on T1gd (0.41 mm) compared with T2 (0.35 mm). The largest variations were found at the tumor-choroid interface due to peritumoral enhancement (T1gd, 0.62 mm; T2, 0.52 mm). As a result, a larger part of this tumor-choroid interface appeared to be included on T1gd-based GTVs compared with T2, explaining the smaller volumes on T2. CONCLUSIONS: The interobserver variation of 0.4 mm on MRI are low with respect to the voxel size of 0.8 mm, enabling small treatment margins. We recommend delineation based on the T1gd-weighted scans, as choroidal tumor extensions might be missed. Elsevier 2022-12-24 /pmc/articles/PMC9860418/ /pubmed/36691449 http://dx.doi.org/10.1016/j.adro.2022.101149 Text en © 2022 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Scientific Article
Jaarsma-Coes, Myriam G.
Klaassen, Lisa
Verbist, Berit M.
Vu, T.H. Khanh
Klaver, Yvonne L.B.
Rodrigues, Myra F.
Nabarro, Claire
Luyten, Gregorius P.M.
Rasch, Coen R.N.
van Herk, Marcel
Beenakker, Jan-Willem M.
Inter-Observer Variability in MR-Based Target Volume Delineation of Uveal Melanoma
title Inter-Observer Variability in MR-Based Target Volume Delineation of Uveal Melanoma
title_full Inter-Observer Variability in MR-Based Target Volume Delineation of Uveal Melanoma
title_fullStr Inter-Observer Variability in MR-Based Target Volume Delineation of Uveal Melanoma
title_full_unstemmed Inter-Observer Variability in MR-Based Target Volume Delineation of Uveal Melanoma
title_short Inter-Observer Variability in MR-Based Target Volume Delineation of Uveal Melanoma
title_sort inter-observer variability in mr-based target volume delineation of uveal melanoma
topic Scientific Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9860418/
https://www.ncbi.nlm.nih.gov/pubmed/36691449
http://dx.doi.org/10.1016/j.adro.2022.101149
work_keys_str_mv AT jaarsmacoesmyriamg interobservervariabilityinmrbasedtargetvolumedelineationofuvealmelanoma
AT klaassenlisa interobservervariabilityinmrbasedtargetvolumedelineationofuvealmelanoma
AT verbistberitm interobservervariabilityinmrbasedtargetvolumedelineationofuvealmelanoma
AT vuthkhanh interobservervariabilityinmrbasedtargetvolumedelineationofuvealmelanoma
AT klaveryvonnelb interobservervariabilityinmrbasedtargetvolumedelineationofuvealmelanoma
AT rodriguesmyraf interobservervariabilityinmrbasedtargetvolumedelineationofuvealmelanoma
AT nabarroclaire interobservervariabilityinmrbasedtargetvolumedelineationofuvealmelanoma
AT luytengregoriuspm interobservervariabilityinmrbasedtargetvolumedelineationofuvealmelanoma
AT raschcoenrn interobservervariabilityinmrbasedtargetvolumedelineationofuvealmelanoma
AT vanherkmarcel interobservervariabilityinmrbasedtargetvolumedelineationofuvealmelanoma
AT beenakkerjanwillemm interobservervariabilityinmrbasedtargetvolumedelineationofuvealmelanoma