Cargando…
Wide-Viewing-Angle Integral Imaging System with Full-Effective-Pixels Elemental Image Array
There exists a defect of the narrow viewing angle in the conventional integral imaging system. One reason for this is that only partial pixels of each elemental image contribute to the viewing angle and the others cause image flips. In this paper, a wide-viewing-angle integral imaging system with a...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9860876/ https://www.ncbi.nlm.nih.gov/pubmed/36677286 http://dx.doi.org/10.3390/mi14010225 |
_version_ | 1784874700129697792 |
---|---|
author | Liu, Zesheng Li, Dahai Deng, Huan |
author_facet | Liu, Zesheng Li, Dahai Deng, Huan |
author_sort | Liu, Zesheng |
collection | PubMed |
description | There exists a defect of the narrow viewing angle in the conventional integral imaging system. One reason for this is that only partial pixels of each elemental image contribute to the viewing angle and the others cause image flips. In this paper, a wide-viewing-angle integral imaging system with a full-effective-pixels elemental image array (FEP-EIA) was proposed. The correspondence between viewpoints and pixel coordinates within the elemental image array was built up, and effective pixel blocks and pixels leading to flipping images were deduced. Then, a pixel replacement method was proposed to generate the FEP-EIAs, which adapt to different viewing distances. As a result, the viewing angle of the proposed integral imaging system was effectively extended through the replacement of the pixels, which caused the image flips. Experiment results demonstrated that wide viewing angles are available for the proposed integral imaging system regardless of the viewing distances. |
format | Online Article Text |
id | pubmed-9860876 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-98608762023-01-22 Wide-Viewing-Angle Integral Imaging System with Full-Effective-Pixels Elemental Image Array Liu, Zesheng Li, Dahai Deng, Huan Micromachines (Basel) Article There exists a defect of the narrow viewing angle in the conventional integral imaging system. One reason for this is that only partial pixels of each elemental image contribute to the viewing angle and the others cause image flips. In this paper, a wide-viewing-angle integral imaging system with a full-effective-pixels elemental image array (FEP-EIA) was proposed. The correspondence between viewpoints and pixel coordinates within the elemental image array was built up, and effective pixel blocks and pixels leading to flipping images were deduced. Then, a pixel replacement method was proposed to generate the FEP-EIAs, which adapt to different viewing distances. As a result, the viewing angle of the proposed integral imaging system was effectively extended through the replacement of the pixels, which caused the image flips. Experiment results demonstrated that wide viewing angles are available for the proposed integral imaging system regardless of the viewing distances. MDPI 2023-01-15 /pmc/articles/PMC9860876/ /pubmed/36677286 http://dx.doi.org/10.3390/mi14010225 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Liu, Zesheng Li, Dahai Deng, Huan Wide-Viewing-Angle Integral Imaging System with Full-Effective-Pixels Elemental Image Array |
title | Wide-Viewing-Angle Integral Imaging System with Full-Effective-Pixels Elemental Image Array |
title_full | Wide-Viewing-Angle Integral Imaging System with Full-Effective-Pixels Elemental Image Array |
title_fullStr | Wide-Viewing-Angle Integral Imaging System with Full-Effective-Pixels Elemental Image Array |
title_full_unstemmed | Wide-Viewing-Angle Integral Imaging System with Full-Effective-Pixels Elemental Image Array |
title_short | Wide-Viewing-Angle Integral Imaging System with Full-Effective-Pixels Elemental Image Array |
title_sort | wide-viewing-angle integral imaging system with full-effective-pixels elemental image array |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9860876/ https://www.ncbi.nlm.nih.gov/pubmed/36677286 http://dx.doi.org/10.3390/mi14010225 |
work_keys_str_mv | AT liuzesheng wideviewingangleintegralimagingsystemwithfulleffectivepixelselementalimagearray AT lidahai wideviewingangleintegralimagingsystemwithfulleffectivepixelselementalimagearray AT denghuan wideviewingangleintegralimagingsystemwithfulleffectivepixelselementalimagearray |