Cargando…

Risk Evaluation for Coating Thickness Conformity Assessment

This paper presents the conformity assessment process of the epoxy coating thickness applied on water pipes made of gray cast iron with the specifications given for this kind of coating appliance. An epoxy coating was applied to prevent a special form of corrosion called the graphitization of cast i...

Descripción completa

Detalles Bibliográficos
Autores principales: Božić, Dubravka, Samardžija, Marina, Kurtela, Marin, Keran, Zdenka, Runje, Biserka
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9861233/
https://www.ncbi.nlm.nih.gov/pubmed/36676496
http://dx.doi.org/10.3390/ma16020758
_version_ 1784874790292553728
author Božić, Dubravka
Samardžija, Marina
Kurtela, Marin
Keran, Zdenka
Runje, Biserka
author_facet Božić, Dubravka
Samardžija, Marina
Kurtela, Marin
Keran, Zdenka
Runje, Biserka
author_sort Božić, Dubravka
collection PubMed
description This paper presents the conformity assessment process of the epoxy coating thickness applied on water pipes made of gray cast iron with the specifications given for this kind of coating appliance. An epoxy coating was applied to prevent a special form of corrosion called the graphitization of cast iron. In order for the pipe to withstand its designed service life, it is necessary to ensure the required thickness of the applied coating. In accordance with the EN 877 norm, the thickness of the epoxy coating on the pipes for the projected corrosiveness of the environment C4 and the durability of 20 years is at least 70 μm and this indicates the required accuracy of the product. To achieve the desired product quality, statistical control of the coating application process was carried out and the impact of uncertainty associated with the measurement result was analyzed. Considering the quality of the coating application process and the quality of the measuring system, and to ensure the quality of products and to reduce consumer risk, the optimal thickness of the coating was determined.
format Online
Article
Text
id pubmed-9861233
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-98612332023-01-22 Risk Evaluation for Coating Thickness Conformity Assessment Božić, Dubravka Samardžija, Marina Kurtela, Marin Keran, Zdenka Runje, Biserka Materials (Basel) Article This paper presents the conformity assessment process of the epoxy coating thickness applied on water pipes made of gray cast iron with the specifications given for this kind of coating appliance. An epoxy coating was applied to prevent a special form of corrosion called the graphitization of cast iron. In order for the pipe to withstand its designed service life, it is necessary to ensure the required thickness of the applied coating. In accordance with the EN 877 norm, the thickness of the epoxy coating on the pipes for the projected corrosiveness of the environment C4 and the durability of 20 years is at least 70 μm and this indicates the required accuracy of the product. To achieve the desired product quality, statistical control of the coating application process was carried out and the impact of uncertainty associated with the measurement result was analyzed. Considering the quality of the coating application process and the quality of the measuring system, and to ensure the quality of products and to reduce consumer risk, the optimal thickness of the coating was determined. MDPI 2023-01-12 /pmc/articles/PMC9861233/ /pubmed/36676496 http://dx.doi.org/10.3390/ma16020758 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Božić, Dubravka
Samardžija, Marina
Kurtela, Marin
Keran, Zdenka
Runje, Biserka
Risk Evaluation for Coating Thickness Conformity Assessment
title Risk Evaluation for Coating Thickness Conformity Assessment
title_full Risk Evaluation for Coating Thickness Conformity Assessment
title_fullStr Risk Evaluation for Coating Thickness Conformity Assessment
title_full_unstemmed Risk Evaluation for Coating Thickness Conformity Assessment
title_short Risk Evaluation for Coating Thickness Conformity Assessment
title_sort risk evaluation for coating thickness conformity assessment
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9861233/
https://www.ncbi.nlm.nih.gov/pubmed/36676496
http://dx.doi.org/10.3390/ma16020758
work_keys_str_mv AT bozicdubravka riskevaluationforcoatingthicknessconformityassessment
AT samardzijamarina riskevaluationforcoatingthicknessconformityassessment
AT kurtelamarin riskevaluationforcoatingthicknessconformityassessment
AT keranzdenka riskevaluationforcoatingthicknessconformityassessment
AT runjebiserka riskevaluationforcoatingthicknessconformityassessment