Accurate Detection and Localization of Water Pipe Leaks through Model-Based TDR Inversion
The problem of water scarcity affects many areas of the world due to water mismanagement and overconsumption and, more recently, to climate change. Monitoring the integrity of distribution systems is, therefore, increasingly important to avoid the waste of clean water. This paper presents a new sign...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9861414/ https://www.ncbi.nlm.nih.gov/pubmed/36679507 http://dx.doi.org/10.3390/s23020710 |
_version_ | 1784874835518685184 |
---|---|
author | Scarpetta, Marco Cataldo, Andrea Spadavecchia, Maurizio Piuzzi, Emanuele Masciullo, Antonio Giaquinto, Nicola |
author_facet | Scarpetta, Marco Cataldo, Andrea Spadavecchia, Maurizio Piuzzi, Emanuele Masciullo, Antonio Giaquinto, Nicola |
author_sort | Scarpetta, Marco |
collection | PubMed |
description | The problem of water scarcity affects many areas of the world due to water mismanagement and overconsumption and, more recently, to climate change. Monitoring the integrity of distribution systems is, therefore, increasingly important to avoid the waste of clean water. This paper presents a new signal processing technique for enhancing the performance of the methodology of leak detection in water distribution pipes based on time domain reflectometry (TDR). The new technique is based on a particular kind of TDR inversion (spatial TDR) based on a “gray-box” lumped parameter model of the system. The model does not include, e.g., radiative phenomena, non-TEM (transverse electromagnetic) modes etc. but is capable of reproducing accurately the complicated reflectograms obtained by a TDR leak detection system assuming a proper profile of capacitance per unit length along the sensing element. Even more importantly, the model is identified using only the reflectograms taken by the system with very little prior information about the system components. The developed technique is able to estimate with good accuracy, from reflectograms with unclear or ambiguous interpretation, the position and the extension of a region where water is located. The measurement is obtained without prior electromagnetic characterization of the TDR system components and without the need of modeling or quantifying a number of electromagnetic effects typical of on-site measurements. |
format | Online Article Text |
id | pubmed-9861414 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-98614142023-01-22 Accurate Detection and Localization of Water Pipe Leaks through Model-Based TDR Inversion Scarpetta, Marco Cataldo, Andrea Spadavecchia, Maurizio Piuzzi, Emanuele Masciullo, Antonio Giaquinto, Nicola Sensors (Basel) Article The problem of water scarcity affects many areas of the world due to water mismanagement and overconsumption and, more recently, to climate change. Monitoring the integrity of distribution systems is, therefore, increasingly important to avoid the waste of clean water. This paper presents a new signal processing technique for enhancing the performance of the methodology of leak detection in water distribution pipes based on time domain reflectometry (TDR). The new technique is based on a particular kind of TDR inversion (spatial TDR) based on a “gray-box” lumped parameter model of the system. The model does not include, e.g., radiative phenomena, non-TEM (transverse electromagnetic) modes etc. but is capable of reproducing accurately the complicated reflectograms obtained by a TDR leak detection system assuming a proper profile of capacitance per unit length along the sensing element. Even more importantly, the model is identified using only the reflectograms taken by the system with very little prior information about the system components. The developed technique is able to estimate with good accuracy, from reflectograms with unclear or ambiguous interpretation, the position and the extension of a region where water is located. The measurement is obtained without prior electromagnetic characterization of the TDR system components and without the need of modeling or quantifying a number of electromagnetic effects typical of on-site measurements. MDPI 2023-01-08 /pmc/articles/PMC9861414/ /pubmed/36679507 http://dx.doi.org/10.3390/s23020710 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Scarpetta, Marco Cataldo, Andrea Spadavecchia, Maurizio Piuzzi, Emanuele Masciullo, Antonio Giaquinto, Nicola Accurate Detection and Localization of Water Pipe Leaks through Model-Based TDR Inversion |
title | Accurate Detection and Localization of Water Pipe Leaks through Model-Based TDR Inversion |
title_full | Accurate Detection and Localization of Water Pipe Leaks through Model-Based TDR Inversion |
title_fullStr | Accurate Detection and Localization of Water Pipe Leaks through Model-Based TDR Inversion |
title_full_unstemmed | Accurate Detection and Localization of Water Pipe Leaks through Model-Based TDR Inversion |
title_short | Accurate Detection and Localization of Water Pipe Leaks through Model-Based TDR Inversion |
title_sort | accurate detection and localization of water pipe leaks through model-based tdr inversion |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9861414/ https://www.ncbi.nlm.nih.gov/pubmed/36679507 http://dx.doi.org/10.3390/s23020710 |
work_keys_str_mv | AT scarpettamarco accuratedetectionandlocalizationofwaterpipeleaksthroughmodelbasedtdrinversion AT cataldoandrea accuratedetectionandlocalizationofwaterpipeleaksthroughmodelbasedtdrinversion AT spadavecchiamaurizio accuratedetectionandlocalizationofwaterpipeleaksthroughmodelbasedtdrinversion AT piuzziemanuele accuratedetectionandlocalizationofwaterpipeleaksthroughmodelbasedtdrinversion AT masciulloantonio accuratedetectionandlocalizationofwaterpipeleaksthroughmodelbasedtdrinversion AT giaquintonicola accuratedetectionandlocalizationofwaterpipeleaksthroughmodelbasedtdrinversion |