Cargando…

Augmentation Index in Patients with Thoracic Aortic Aneurysm: A Matched Case-Control Study

Thoracic aortic aneurysms (TAA) may be associated with complications such as rupture and dissection, which can lead to a fatal outcome. Increased central arterial stiffness has been proposed to be present in patients with TAA compared to unmatched controls. We aimed to assess whether wall properties...

Descripción completa

Detalles Bibliográficos
Autores principales: Baumgartner, Patrick, Rejmer, Protazy, Osswald, Martin, Malesevic, Stefan, Sievi, Noriane A., Roeder, Maurice, Herth, Jonas, Stämpfli, Simon F., Clarenbach, Christian F., Tanner, Felix C., Gaisl, Thomas, Kohler, Malcolm
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9861448/
https://www.ncbi.nlm.nih.gov/pubmed/36661901
http://dx.doi.org/10.3390/jcdd10010006
_version_ 1784874844058288128
author Baumgartner, Patrick
Rejmer, Protazy
Osswald, Martin
Malesevic, Stefan
Sievi, Noriane A.
Roeder, Maurice
Herth, Jonas
Stämpfli, Simon F.
Clarenbach, Christian F.
Tanner, Felix C.
Gaisl, Thomas
Kohler, Malcolm
author_facet Baumgartner, Patrick
Rejmer, Protazy
Osswald, Martin
Malesevic, Stefan
Sievi, Noriane A.
Roeder, Maurice
Herth, Jonas
Stämpfli, Simon F.
Clarenbach, Christian F.
Tanner, Felix C.
Gaisl, Thomas
Kohler, Malcolm
author_sort Baumgartner, Patrick
collection PubMed
description Thoracic aortic aneurysms (TAA) may be associated with complications such as rupture and dissection, which can lead to a fatal outcome. Increased central arterial stiffness has been proposed to be present in patients with TAA compared to unmatched controls. We aimed to assess whether wall properties in patients with TAA are also altered when compared to a matched control group. Applanation tonometry was performed in 74 adults with TAA and 74 sex, age, weight, height, and left ventricular ejection fraction matched controls. Subsequently analysis of the pulse wave was done using the SphygmoCor System. For comparing the two groups, AIx was adjusted to a heart rate of 75/min (AIx@75). 148 1-to-1 matched participants were included in the final model. There was no significant difference in the Alx@75 between the TAA group and the matched control group [mean (SD) of 24.7 (11.2) % and 22.8 (11.2) %, p = 0.240]. Adjusted for known cardiovascular risk factors, there was no association between TAA and AIx@75. Patients with TAA showed comparable arterial wall properties to cardiovascular risk factor matched controls. Since higher arterial stiffness is associated with TAA progression, it remains to be investigated if increased central arterial stiffness is a relevant factor of TAA emergence.
format Online
Article
Text
id pubmed-9861448
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-98614482023-01-22 Augmentation Index in Patients with Thoracic Aortic Aneurysm: A Matched Case-Control Study Baumgartner, Patrick Rejmer, Protazy Osswald, Martin Malesevic, Stefan Sievi, Noriane A. Roeder, Maurice Herth, Jonas Stämpfli, Simon F. Clarenbach, Christian F. Tanner, Felix C. Gaisl, Thomas Kohler, Malcolm J Cardiovasc Dev Dis Article Thoracic aortic aneurysms (TAA) may be associated with complications such as rupture and dissection, which can lead to a fatal outcome. Increased central arterial stiffness has been proposed to be present in patients with TAA compared to unmatched controls. We aimed to assess whether wall properties in patients with TAA are also altered when compared to a matched control group. Applanation tonometry was performed in 74 adults with TAA and 74 sex, age, weight, height, and left ventricular ejection fraction matched controls. Subsequently analysis of the pulse wave was done using the SphygmoCor System. For comparing the two groups, AIx was adjusted to a heart rate of 75/min (AIx@75). 148 1-to-1 matched participants were included in the final model. There was no significant difference in the Alx@75 between the TAA group and the matched control group [mean (SD) of 24.7 (11.2) % and 22.8 (11.2) %, p = 0.240]. Adjusted for known cardiovascular risk factors, there was no association between TAA and AIx@75. Patients with TAA showed comparable arterial wall properties to cardiovascular risk factor matched controls. Since higher arterial stiffness is associated with TAA progression, it remains to be investigated if increased central arterial stiffness is a relevant factor of TAA emergence. MDPI 2022-12-23 /pmc/articles/PMC9861448/ /pubmed/36661901 http://dx.doi.org/10.3390/jcdd10010006 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Baumgartner, Patrick
Rejmer, Protazy
Osswald, Martin
Malesevic, Stefan
Sievi, Noriane A.
Roeder, Maurice
Herth, Jonas
Stämpfli, Simon F.
Clarenbach, Christian F.
Tanner, Felix C.
Gaisl, Thomas
Kohler, Malcolm
Augmentation Index in Patients with Thoracic Aortic Aneurysm: A Matched Case-Control Study
title Augmentation Index in Patients with Thoracic Aortic Aneurysm: A Matched Case-Control Study
title_full Augmentation Index in Patients with Thoracic Aortic Aneurysm: A Matched Case-Control Study
title_fullStr Augmentation Index in Patients with Thoracic Aortic Aneurysm: A Matched Case-Control Study
title_full_unstemmed Augmentation Index in Patients with Thoracic Aortic Aneurysm: A Matched Case-Control Study
title_short Augmentation Index in Patients with Thoracic Aortic Aneurysm: A Matched Case-Control Study
title_sort augmentation index in patients with thoracic aortic aneurysm: a matched case-control study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9861448/
https://www.ncbi.nlm.nih.gov/pubmed/36661901
http://dx.doi.org/10.3390/jcdd10010006
work_keys_str_mv AT baumgartnerpatrick augmentationindexinpatientswiththoracicaorticaneurysmamatchedcasecontrolstudy
AT rejmerprotazy augmentationindexinpatientswiththoracicaorticaneurysmamatchedcasecontrolstudy
AT osswaldmartin augmentationindexinpatientswiththoracicaorticaneurysmamatchedcasecontrolstudy
AT malesevicstefan augmentationindexinpatientswiththoracicaorticaneurysmamatchedcasecontrolstudy
AT sievinorianea augmentationindexinpatientswiththoracicaorticaneurysmamatchedcasecontrolstudy
AT roedermaurice augmentationindexinpatientswiththoracicaorticaneurysmamatchedcasecontrolstudy
AT herthjonas augmentationindexinpatientswiththoracicaorticaneurysmamatchedcasecontrolstudy
AT stampflisimonf augmentationindexinpatientswiththoracicaorticaneurysmamatchedcasecontrolstudy
AT clarenbachchristianf augmentationindexinpatientswiththoracicaorticaneurysmamatchedcasecontrolstudy
AT tannerfelixc augmentationindexinpatientswiththoracicaorticaneurysmamatchedcasecontrolstudy
AT gaislthomas augmentationindexinpatientswiththoracicaorticaneurysmamatchedcasecontrolstudy
AT kohlermalcolm augmentationindexinpatientswiththoracicaorticaneurysmamatchedcasecontrolstudy