Cargando…
Corrosion Fatigue Degradation Characteristics of Galvanized and Galfan High-Strength Steel Wire
Cables are the main load-bearing components of a cable bridge and typically composed of high strength steel wires with a galvanized coating or Galfan coating. Galfan steel wire has recently started to be widely used because of its better corrosion resistance than galvanized steel wire. The corrosion...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9861807/ https://www.ncbi.nlm.nih.gov/pubmed/36676445 http://dx.doi.org/10.3390/ma16020708 |
_version_ | 1784874933891891200 |
---|---|
author | Zhao, Yue Su, Botong Fan, Xiaobo Yuan, Yangguang Zhu, Yiyun |
author_facet | Zhao, Yue Su, Botong Fan, Xiaobo Yuan, Yangguang Zhu, Yiyun |
author_sort | Zhao, Yue |
collection | PubMed |
description | Cables are the main load-bearing components of a cable bridge and typically composed of high strength steel wires with a galvanized coating or Galfan coating. Galfan steel wire has recently started to be widely used because of its better corrosion resistance than galvanized steel wire. The corrosion characteristics of the coating and the difference in the corrosion fatigue process of the two types of steel wire are unclear. To further improve the service performance and maintenance of cable bridges, this study investigated the corrosion characteristics of galvanized steel wire and Galfan steel wire through accelerated corrosion tests and established a time-varying model of uniform corrosion and pitting corrosion of high-strength steel wire. Then, a long-span suspension bridge was taken as the research object, and the corrosion fatigue degradation of the two kinds of steel wire under a traffic load was analyzed on the basis of traffic monitoring data. The results showed that the uniform corrosion of the two types of steel wire conformed to an exponential development trend, the corrosion coefficient of galvanized steel wire conformed to the normal distribution, and the corrosion coefficient of Galfan steel wire conformed to the Cauchy distribution. The maximum pitting coefficient distribution of the two kinds of steel wire conformed to the generalized extreme value distribution. The location parameters and scale parameters of the two distributions showed an exponential downward trend with the increase of corrosion duration. When the traffic intensity was low, the corrosion characteristics of the steel wire was the main factor affecting its service life, and the average service life of Galfan steel wire was significantly higher than that of galvanized steel wire. Under a dense traffic flow, the service life of the steel wire was mainly controlled by the traffic load, and the service life of Galfan steel wire was slightly improved. Effective anti-corrosion measures are a key factor for improving the service life of steel wire. |
format | Online Article Text |
id | pubmed-9861807 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-98618072023-01-22 Corrosion Fatigue Degradation Characteristics of Galvanized and Galfan High-Strength Steel Wire Zhao, Yue Su, Botong Fan, Xiaobo Yuan, Yangguang Zhu, Yiyun Materials (Basel) Article Cables are the main load-bearing components of a cable bridge and typically composed of high strength steel wires with a galvanized coating or Galfan coating. Galfan steel wire has recently started to be widely used because of its better corrosion resistance than galvanized steel wire. The corrosion characteristics of the coating and the difference in the corrosion fatigue process of the two types of steel wire are unclear. To further improve the service performance and maintenance of cable bridges, this study investigated the corrosion characteristics of galvanized steel wire and Galfan steel wire through accelerated corrosion tests and established a time-varying model of uniform corrosion and pitting corrosion of high-strength steel wire. Then, a long-span suspension bridge was taken as the research object, and the corrosion fatigue degradation of the two kinds of steel wire under a traffic load was analyzed on the basis of traffic monitoring data. The results showed that the uniform corrosion of the two types of steel wire conformed to an exponential development trend, the corrosion coefficient of galvanized steel wire conformed to the normal distribution, and the corrosion coefficient of Galfan steel wire conformed to the Cauchy distribution. The maximum pitting coefficient distribution of the two kinds of steel wire conformed to the generalized extreme value distribution. The location parameters and scale parameters of the two distributions showed an exponential downward trend with the increase of corrosion duration. When the traffic intensity was low, the corrosion characteristics of the steel wire was the main factor affecting its service life, and the average service life of Galfan steel wire was significantly higher than that of galvanized steel wire. Under a dense traffic flow, the service life of the steel wire was mainly controlled by the traffic load, and the service life of Galfan steel wire was slightly improved. Effective anti-corrosion measures are a key factor for improving the service life of steel wire. MDPI 2023-01-11 /pmc/articles/PMC9861807/ /pubmed/36676445 http://dx.doi.org/10.3390/ma16020708 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Zhao, Yue Su, Botong Fan, Xiaobo Yuan, Yangguang Zhu, Yiyun Corrosion Fatigue Degradation Characteristics of Galvanized and Galfan High-Strength Steel Wire |
title | Corrosion Fatigue Degradation Characteristics of Galvanized and Galfan High-Strength Steel Wire |
title_full | Corrosion Fatigue Degradation Characteristics of Galvanized and Galfan High-Strength Steel Wire |
title_fullStr | Corrosion Fatigue Degradation Characteristics of Galvanized and Galfan High-Strength Steel Wire |
title_full_unstemmed | Corrosion Fatigue Degradation Characteristics of Galvanized and Galfan High-Strength Steel Wire |
title_short | Corrosion Fatigue Degradation Characteristics of Galvanized and Galfan High-Strength Steel Wire |
title_sort | corrosion fatigue degradation characteristics of galvanized and galfan high-strength steel wire |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9861807/ https://www.ncbi.nlm.nih.gov/pubmed/36676445 http://dx.doi.org/10.3390/ma16020708 |
work_keys_str_mv | AT zhaoyue corrosionfatiguedegradationcharacteristicsofgalvanizedandgalfanhighstrengthsteelwire AT subotong corrosionfatiguedegradationcharacteristicsofgalvanizedandgalfanhighstrengthsteelwire AT fanxiaobo corrosionfatiguedegradationcharacteristicsofgalvanizedandgalfanhighstrengthsteelwire AT yuanyangguang corrosionfatiguedegradationcharacteristicsofgalvanizedandgalfanhighstrengthsteelwire AT zhuyiyun corrosionfatiguedegradationcharacteristicsofgalvanizedandgalfanhighstrengthsteelwire |