Cargando…

Simultaneous Method for Selected PBDEs and HBCDDs in Foodstuffs Using Gas Chromatography—Tandem Mass Spectrometry and Liquid Chromatography—Tandem Mass Spectrometry

Flame retardants are added to consumer products to retard the ignition of combustible materials. Technical mixtures of polybrominated diphenyl ethers (PBDEs) and hexabromocyclododecane (HBCDD) were massively used for several decades. They are bioaccumulative, persistent, and have adverse effects on...

Descripción completa

Detalles Bibliográficos
Autores principales: Lipičar, Eva, Fras, Danijela, Javernik, Nino, Prosen, Helena
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9862769/
https://www.ncbi.nlm.nih.gov/pubmed/36668741
http://dx.doi.org/10.3390/toxics11010015
_version_ 1784875172563517440
author Lipičar, Eva
Fras, Danijela
Javernik, Nino
Prosen, Helena
author_facet Lipičar, Eva
Fras, Danijela
Javernik, Nino
Prosen, Helena
author_sort Lipičar, Eva
collection PubMed
description Flame retardants are added to consumer products to retard the ignition of combustible materials. Technical mixtures of polybrominated diphenyl ethers (PBDEs) and hexabromocyclododecane (HBCDD) were massively used for several decades. They are bioaccumulative, persistent, and have adverse effects on organisms. Recognised as persistent organic pollutants, they are banned almost worldwide. Food is the principal source of human exposure. Yet, no maximum residue limits for food have been established in the EU. Nevertheless, monitoring of specific congeners is recommended. Simultaneous analysis of HBCDDs and PBDEs is rarely encountered, especially including BDE-209, as this thermally unstable congener is particularly challenging for analysis. We have developed a method for the simultaneous determination of all relevant PBDEs and HBCDDs recommended for monitoring by the EU. In the method, single sample preparation is used for different types of foodstuffs, applying ultrasound-assisted extraction, clean-up by gel permeation, and adsorption chromatography. Analyses were performed on the same extract, first by GC-MS/MS(EI) method for PBDEs and followed by LC-MS/MS(ESI) method for HBCDDs. The analytical method was validated on a blank sample of milk formula at 2–3 fortification levels, including recommended LOQ level of 0.01 µg/kg wet weight. Satisfactory accuracy with recoveries 85–119%, intra-day precision (1.5–11.3%), and inter-day precision (4.3–18.4%) was obtained. The method ensures LOQs that are compliant with the EU recommendations for all PBDEs and HBCDDs, including BDE-209. Method applicability was further confirmed on proficiency testing samples of baby food, fish, and citrus.
format Online
Article
Text
id pubmed-9862769
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-98627692023-01-22 Simultaneous Method for Selected PBDEs and HBCDDs in Foodstuffs Using Gas Chromatography—Tandem Mass Spectrometry and Liquid Chromatography—Tandem Mass Spectrometry Lipičar, Eva Fras, Danijela Javernik, Nino Prosen, Helena Toxics Article Flame retardants are added to consumer products to retard the ignition of combustible materials. Technical mixtures of polybrominated diphenyl ethers (PBDEs) and hexabromocyclododecane (HBCDD) were massively used for several decades. They are bioaccumulative, persistent, and have adverse effects on organisms. Recognised as persistent organic pollutants, they are banned almost worldwide. Food is the principal source of human exposure. Yet, no maximum residue limits for food have been established in the EU. Nevertheless, monitoring of specific congeners is recommended. Simultaneous analysis of HBCDDs and PBDEs is rarely encountered, especially including BDE-209, as this thermally unstable congener is particularly challenging for analysis. We have developed a method for the simultaneous determination of all relevant PBDEs and HBCDDs recommended for monitoring by the EU. In the method, single sample preparation is used for different types of foodstuffs, applying ultrasound-assisted extraction, clean-up by gel permeation, and adsorption chromatography. Analyses were performed on the same extract, first by GC-MS/MS(EI) method for PBDEs and followed by LC-MS/MS(ESI) method for HBCDDs. The analytical method was validated on a blank sample of milk formula at 2–3 fortification levels, including recommended LOQ level of 0.01 µg/kg wet weight. Satisfactory accuracy with recoveries 85–119%, intra-day precision (1.5–11.3%), and inter-day precision (4.3–18.4%) was obtained. The method ensures LOQs that are compliant with the EU recommendations for all PBDEs and HBCDDs, including BDE-209. Method applicability was further confirmed on proficiency testing samples of baby food, fish, and citrus. MDPI 2022-12-24 /pmc/articles/PMC9862769/ /pubmed/36668741 http://dx.doi.org/10.3390/toxics11010015 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Lipičar, Eva
Fras, Danijela
Javernik, Nino
Prosen, Helena
Simultaneous Method for Selected PBDEs and HBCDDs in Foodstuffs Using Gas Chromatography—Tandem Mass Spectrometry and Liquid Chromatography—Tandem Mass Spectrometry
title Simultaneous Method for Selected PBDEs and HBCDDs in Foodstuffs Using Gas Chromatography—Tandem Mass Spectrometry and Liquid Chromatography—Tandem Mass Spectrometry
title_full Simultaneous Method for Selected PBDEs and HBCDDs in Foodstuffs Using Gas Chromatography—Tandem Mass Spectrometry and Liquid Chromatography—Tandem Mass Spectrometry
title_fullStr Simultaneous Method for Selected PBDEs and HBCDDs in Foodstuffs Using Gas Chromatography—Tandem Mass Spectrometry and Liquid Chromatography—Tandem Mass Spectrometry
title_full_unstemmed Simultaneous Method for Selected PBDEs and HBCDDs in Foodstuffs Using Gas Chromatography—Tandem Mass Spectrometry and Liquid Chromatography—Tandem Mass Spectrometry
title_short Simultaneous Method for Selected PBDEs and HBCDDs in Foodstuffs Using Gas Chromatography—Tandem Mass Spectrometry and Liquid Chromatography—Tandem Mass Spectrometry
title_sort simultaneous method for selected pbdes and hbcdds in foodstuffs using gas chromatography—tandem mass spectrometry and liquid chromatography—tandem mass spectrometry
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9862769/
https://www.ncbi.nlm.nih.gov/pubmed/36668741
http://dx.doi.org/10.3390/toxics11010015
work_keys_str_mv AT lipicareva simultaneousmethodforselectedpbdesandhbcddsinfoodstuffsusinggaschromatographytandemmassspectrometryandliquidchromatographytandemmassspectrometry
AT frasdanijela simultaneousmethodforselectedpbdesandhbcddsinfoodstuffsusinggaschromatographytandemmassspectrometryandliquidchromatographytandemmassspectrometry
AT javerniknino simultaneousmethodforselectedpbdesandhbcddsinfoodstuffsusinggaschromatographytandemmassspectrometryandliquidchromatographytandemmassspectrometry
AT prosenhelena simultaneousmethodforselectedpbdesandhbcddsinfoodstuffsusinggaschromatographytandemmassspectrometryandliquidchromatographytandemmassspectrometry