Cargando…

The Role of Daily Implant-Based Multiparametric Telemonitoring in Patients with a Ventricular Assist Device

The telemonitoring of heart failure (HF) patients is becoming increasingly important. This study aimed to evaluate the benefit of telemonitoring in end-stage HF patients with a ventricular-assistance device (VAD). A total of 26 HF-patients (66 ± 11 years, 88% male) on VAD therapy with an implantable...

Descripción completa

Detalles Bibliográficos
Autores principales: Guckel, Denise, El Hamriti, Mustapha, Rojas, Sebastian V., Fox, Henrik, Costard-Jäckle, Angelika, Gummert, Jan, Fink, Thomas, Sciacca, Vanessa, Isgandarova, Khuraman, Braun, Martin, Khalaph, Moneeb, Imnadze, Guram, Schramm, René, Morshuis, Michiel, Sommer, Philipp, Sohns, Christian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9864752/
https://www.ncbi.nlm.nih.gov/pubmed/36675986
http://dx.doi.org/10.3390/life13010038
Descripción
Sumario:The telemonitoring of heart failure (HF) patients is becoming increasingly important. This study aimed to evaluate the benefit of telemonitoring in end-stage HF patients with a ventricular-assistance device (VAD). A total of 26 HF-patients (66 ± 11 years, 88% male) on VAD therapy with an implantable cardioverter-defibrillator (ICD) or a cardiac resynchronization defibrillator (CRT-D) including telemonitoring function were enrolled. The long-term follow-up data (4.10 ± 2.58 years) were assessed. All the patients (n = 26, 100%) received daily ICD/CRT-D telemonitoring. In most of the patients (73%, n = 19), the telemedical center had to take action for a mean of three times. An acute alert due to sustained ventricular arrhythmias (VAs) occurred in 12 patients (63%) with 50% of them (n = 6) requiring ICD shock delivery. Eight patients (67%) were hospitalized due to symptomatic VAs. In 11 patients (92%), immediate medication adjustments were recommended. Relevant lead issues were revealed in thirteen patients (50%), with six patients (46%) undergoing consecutive lead revisions. Most of the events (83%) were detected within 24 h. Daily telemonitoring significantly reduced the number of in-hospital device controls by 44% (p < 0.01). The telemonitoring ensured that cardiac arrhythmias and device/lead problems were identified early, allowing pre-emptive and prompt interventions. In addition, the telemonitoring significantly reduced the number of in-hospital device controls in this cohort of HF patients.