Cargando…

Comparison of X-ray Radiant Power Absolute Measurement between a Free-Air Ionization Chamber and a Cryogenic Electrical Substitution Radiometer

Absolute measurement of radiant power in the X-ray region is essential for many applications in astrophysics, spectroscopy, and X-ray diagnostics. Comparison between different measuring methods is an effective way to check their reliability. In the present work, a comparison of X-ray radiant power a...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Fan, Zhao, Yidong, Wang, Peiwei, Tang, Kun, Zheng, Lei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9864874/
https://www.ncbi.nlm.nih.gov/pubmed/36679803
http://dx.doi.org/10.3390/s23021006
_version_ 1784875693258047488
author Li, Fan
Zhao, Yidong
Wang, Peiwei
Tang, Kun
Zheng, Lei
author_facet Li, Fan
Zhao, Yidong
Wang, Peiwei
Tang, Kun
Zheng, Lei
author_sort Li, Fan
collection PubMed
description Absolute measurement of radiant power in the X-ray region is essential for many applications in astrophysics, spectroscopy, and X-ray diagnostics. Comparison between different measuring methods is an effective way to check their reliability. In the present work, a comparison of X-ray radiant power absolute measurement between a free-air ionization chamber and a cryogenic electrical substitution radiometer was performed at Beijing Synchrotron Radiation Facility. The absolute radiant power obtained by these two methods were mutually compared via a transfer standard detector’s spectral responsivity at a photon energy of 10 keV. The result of the comparison showed that the difference was 0.47%. A conclusion was reached that the free-air ionization chamber and the cryogenic electrical substitution radiometer agreed within the combined relative uncertainty of 3.35%.
format Online
Article
Text
id pubmed-9864874
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-98648742023-01-22 Comparison of X-ray Radiant Power Absolute Measurement between a Free-Air Ionization Chamber and a Cryogenic Electrical Substitution Radiometer Li, Fan Zhao, Yidong Wang, Peiwei Tang, Kun Zheng, Lei Sensors (Basel) Article Absolute measurement of radiant power in the X-ray region is essential for many applications in astrophysics, spectroscopy, and X-ray diagnostics. Comparison between different measuring methods is an effective way to check their reliability. In the present work, a comparison of X-ray radiant power absolute measurement between a free-air ionization chamber and a cryogenic electrical substitution radiometer was performed at Beijing Synchrotron Radiation Facility. The absolute radiant power obtained by these two methods were mutually compared via a transfer standard detector’s spectral responsivity at a photon energy of 10 keV. The result of the comparison showed that the difference was 0.47%. A conclusion was reached that the free-air ionization chamber and the cryogenic electrical substitution radiometer agreed within the combined relative uncertainty of 3.35%. MDPI 2023-01-15 /pmc/articles/PMC9864874/ /pubmed/36679803 http://dx.doi.org/10.3390/s23021006 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Li, Fan
Zhao, Yidong
Wang, Peiwei
Tang, Kun
Zheng, Lei
Comparison of X-ray Radiant Power Absolute Measurement between a Free-Air Ionization Chamber and a Cryogenic Electrical Substitution Radiometer
title Comparison of X-ray Radiant Power Absolute Measurement between a Free-Air Ionization Chamber and a Cryogenic Electrical Substitution Radiometer
title_full Comparison of X-ray Radiant Power Absolute Measurement between a Free-Air Ionization Chamber and a Cryogenic Electrical Substitution Radiometer
title_fullStr Comparison of X-ray Radiant Power Absolute Measurement between a Free-Air Ionization Chamber and a Cryogenic Electrical Substitution Radiometer
title_full_unstemmed Comparison of X-ray Radiant Power Absolute Measurement between a Free-Air Ionization Chamber and a Cryogenic Electrical Substitution Radiometer
title_short Comparison of X-ray Radiant Power Absolute Measurement between a Free-Air Ionization Chamber and a Cryogenic Electrical Substitution Radiometer
title_sort comparison of x-ray radiant power absolute measurement between a free-air ionization chamber and a cryogenic electrical substitution radiometer
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9864874/
https://www.ncbi.nlm.nih.gov/pubmed/36679803
http://dx.doi.org/10.3390/s23021006
work_keys_str_mv AT lifan comparisonofxrayradiantpowerabsolutemeasurementbetweenafreeairionizationchamberandacryogenicelectricalsubstitutionradiometer
AT zhaoyidong comparisonofxrayradiantpowerabsolutemeasurementbetweenafreeairionizationchamberandacryogenicelectricalsubstitutionradiometer
AT wangpeiwei comparisonofxrayradiantpowerabsolutemeasurementbetweenafreeairionizationchamberandacryogenicelectricalsubstitutionradiometer
AT tangkun comparisonofxrayradiantpowerabsolutemeasurementbetweenafreeairionizationchamberandacryogenicelectricalsubstitutionradiometer
AT zhenglei comparisonofxrayradiantpowerabsolutemeasurementbetweenafreeairionizationchamberandacryogenicelectricalsubstitutionradiometer