Cargando…
Magnetic Energy Losses and Temperature Control System for Giant Magnetostrictive Transducer
The giant magnetostrictive transducer (GMT) can be widely used in ultra-precision machining in precision-fluid-control fields. The temperature stability of GMT is critical for the reliable generation of output characteristics. This study presents a magnetic-energy-losses method for the GMT working a...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9864965/ https://www.ncbi.nlm.nih.gov/pubmed/36677238 http://dx.doi.org/10.3390/mi14010177 |
Sumario: | The giant magnetostrictive transducer (GMT) can be widely used in ultra-precision machining in precision-fluid-control fields. The temperature stability of GMT is critical for the reliable generation of output characteristics. This study presents a magnetic-energy-losses method for the GMT working at high frequency, and designs a temperature-stable control system to improve energy transmission and heat dissipation. Based on the loss-separation theory and experimental data, the temperature-rise characteristics of the transducer are analyzed. The temperature rise considers the effects of hysteresis loss, the eddy-current loss, the anomalous loss and the Joule heat. A constitutive relation among losses, frequency and magnetic-flux density is given. The temperature distribution of the transducer can be quickly and accurately calculated, using the constitutive equation. According to the convective heat-transfer and the thermal-compensation method, a temperature-control system is designed. A prototype of the system is then fabricated and tested to verify the feasibility and efficacy of the proposed design methods. The results demonstrate that the output- displacement deviation can be controlled at less than 0.65 μm, and the temperature difference is less than 3 °C. |
---|