Cargando…

Temperature Field and Stress Analysis of the Heavy-Concrete Transfer–Purge Chamber of the Nuclear Power Plant

A transfer–purge chamber (TPC) is a double-steel-plate, heavy-concrete, curved-surface composite structure composed of steel plates, heavy concrete, and shear connectors. It is an important facility in the external refueling system of a nuclear power plant (NPP), providing a safe and reliable biolog...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Xiaohui, Li, Xiaojun, Liu, Xuchen, Wang, Yushi, Liu, Aiwen, He, Qiumei, Hou, Chunlin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9865559/
https://www.ncbi.nlm.nih.gov/pubmed/36676350
http://dx.doi.org/10.3390/ma16020613
_version_ 1784875868326199296
author Wang, Xiaohui
Li, Xiaojun
Liu, Xuchen
Wang, Yushi
Liu, Aiwen
He, Qiumei
Hou, Chunlin
author_facet Wang, Xiaohui
Li, Xiaojun
Liu, Xuchen
Wang, Yushi
Liu, Aiwen
He, Qiumei
Hou, Chunlin
author_sort Wang, Xiaohui
collection PubMed
description A transfer–purge chamber (TPC) is a double-steel-plate, heavy-concrete, curved-surface composite structure composed of steel plates, heavy concrete, and shear connectors. It is an important facility in the external refueling system of a nuclear power plant (NPP), providing a safe and reliable biological shielding space for reactor refueling operations. Temperature load is one of the most important factors that must be considered in the design of NPP structures. The temperature loads experienced by the TPC during its life cycle include those encountered in both normal and abnormal operation, which are distinct. In this study, we investigated the steady state and transient-state temperature fields and stresses of a TPC structure under normal operation and after 48 h of abnormal operation, respectively, which were calculated using Abaqus finite element software and the directly coupled method. During normal operation, the temperature field of the structure shows relatively uniform changes, and the temperature gradient of the internal concrete in the direction of its thickness has a constant value of 0.245 °C/cm. At the junction between the transfer and purge sub-chambers of the TPC, under the influence of wall curvature and deformation constraints, the maximum tensile strain of heavy concrete is 8.84 × 10(−3), the maximum compressive strain is 2.04 × 10(−3), the peak stress of the steel plate is 98.305 MPa, and the peak stress of the stud is 306.725 MPa. After 48 h of abnormal operation, the temperatures of the inner surface of the heavy concrete of the wall, the inner steel plate of the wall, the outer surface of the heavy concrete of the wall, and the inner steel plate of the wall increased by 8.12, 8.11, 0.31, and 0.30 °C, respectively. The tensile strain of the heavy concrete of the wall increased significantly by 52.64%, and the compressive strain of the concrete increased by 67.33%, whereas the stresses of the studs and steel plates increased by only 1.57% and 6.79%, respectively. These results show that the change in the temperature field greatly influences the stress and strain on the TPC structure. As measures for mitigating the development of this unfavorable situation of temperature stress concentration, the temperature operating range should be rationally controlled or the junction structure between the transfer and purge sub-chambers of the TPC optimized accordingly. The results of our study can provide basic data for a dynamic analysis of the TPC under conditions of combined earthquake and temperature loads.
format Online
Article
Text
id pubmed-9865559
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-98655592023-01-22 Temperature Field and Stress Analysis of the Heavy-Concrete Transfer–Purge Chamber of the Nuclear Power Plant Wang, Xiaohui Li, Xiaojun Liu, Xuchen Wang, Yushi Liu, Aiwen He, Qiumei Hou, Chunlin Materials (Basel) Article A transfer–purge chamber (TPC) is a double-steel-plate, heavy-concrete, curved-surface composite structure composed of steel plates, heavy concrete, and shear connectors. It is an important facility in the external refueling system of a nuclear power plant (NPP), providing a safe and reliable biological shielding space for reactor refueling operations. Temperature load is one of the most important factors that must be considered in the design of NPP structures. The temperature loads experienced by the TPC during its life cycle include those encountered in both normal and abnormal operation, which are distinct. In this study, we investigated the steady state and transient-state temperature fields and stresses of a TPC structure under normal operation and after 48 h of abnormal operation, respectively, which were calculated using Abaqus finite element software and the directly coupled method. During normal operation, the temperature field of the structure shows relatively uniform changes, and the temperature gradient of the internal concrete in the direction of its thickness has a constant value of 0.245 °C/cm. At the junction between the transfer and purge sub-chambers of the TPC, under the influence of wall curvature and deformation constraints, the maximum tensile strain of heavy concrete is 8.84 × 10(−3), the maximum compressive strain is 2.04 × 10(−3), the peak stress of the steel plate is 98.305 MPa, and the peak stress of the stud is 306.725 MPa. After 48 h of abnormal operation, the temperatures of the inner surface of the heavy concrete of the wall, the inner steel plate of the wall, the outer surface of the heavy concrete of the wall, and the inner steel plate of the wall increased by 8.12, 8.11, 0.31, and 0.30 °C, respectively. The tensile strain of the heavy concrete of the wall increased significantly by 52.64%, and the compressive strain of the concrete increased by 67.33%, whereas the stresses of the studs and steel plates increased by only 1.57% and 6.79%, respectively. These results show that the change in the temperature field greatly influences the stress and strain on the TPC structure. As measures for mitigating the development of this unfavorable situation of temperature stress concentration, the temperature operating range should be rationally controlled or the junction structure between the transfer and purge sub-chambers of the TPC optimized accordingly. The results of our study can provide basic data for a dynamic analysis of the TPC under conditions of combined earthquake and temperature loads. MDPI 2023-01-09 /pmc/articles/PMC9865559/ /pubmed/36676350 http://dx.doi.org/10.3390/ma16020613 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Wang, Xiaohui
Li, Xiaojun
Liu, Xuchen
Wang, Yushi
Liu, Aiwen
He, Qiumei
Hou, Chunlin
Temperature Field and Stress Analysis of the Heavy-Concrete Transfer–Purge Chamber of the Nuclear Power Plant
title Temperature Field and Stress Analysis of the Heavy-Concrete Transfer–Purge Chamber of the Nuclear Power Plant
title_full Temperature Field and Stress Analysis of the Heavy-Concrete Transfer–Purge Chamber of the Nuclear Power Plant
title_fullStr Temperature Field and Stress Analysis of the Heavy-Concrete Transfer–Purge Chamber of the Nuclear Power Plant
title_full_unstemmed Temperature Field and Stress Analysis of the Heavy-Concrete Transfer–Purge Chamber of the Nuclear Power Plant
title_short Temperature Field and Stress Analysis of the Heavy-Concrete Transfer–Purge Chamber of the Nuclear Power Plant
title_sort temperature field and stress analysis of the heavy-concrete transfer–purge chamber of the nuclear power plant
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9865559/
https://www.ncbi.nlm.nih.gov/pubmed/36676350
http://dx.doi.org/10.3390/ma16020613
work_keys_str_mv AT wangxiaohui temperaturefieldandstressanalysisoftheheavyconcretetransferpurgechamberofthenuclearpowerplant
AT lixiaojun temperaturefieldandstressanalysisoftheheavyconcretetransferpurgechamberofthenuclearpowerplant
AT liuxuchen temperaturefieldandstressanalysisoftheheavyconcretetransferpurgechamberofthenuclearpowerplant
AT wangyushi temperaturefieldandstressanalysisoftheheavyconcretetransferpurgechamberofthenuclearpowerplant
AT liuaiwen temperaturefieldandstressanalysisoftheheavyconcretetransferpurgechamberofthenuclearpowerplant
AT heqiumei temperaturefieldandstressanalysisoftheheavyconcretetransferpurgechamberofthenuclearpowerplant
AT houchunlin temperaturefieldandstressanalysisoftheheavyconcretetransferpurgechamberofthenuclearpowerplant