Innovative C-Arm-Free Navigation Technique for Posterior Spinal Fixation for Atlantoaxial Subluxation: A Technical Note

Study design: Technical note. Objectives: To present a novel C-arm-free technique guided by navigation to insert and place a C1 lateral mass screw. Background and Objectives: Atlantoaxial subluxation (AAS) is a relatively common sequelae in patients with rheumatoid arthritis (RA) and upper cervical...

Descripción completa

Detalles Bibliográficos
Autores principales: Tanaka, Masato, Sake, Naveen, Kim, Dae-Geun, Arataki, Shinya, Desai, Dhvanit, Fujiwara, Yoshihiro, Yamauchi, Taro
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9865610/
https://www.ncbi.nlm.nih.gov/pubmed/36676635
http://dx.doi.org/10.3390/medicina59010011
_version_ 1784875881149235200
author Tanaka, Masato
Sake, Naveen
Kim, Dae-Geun
Arataki, Shinya
Desai, Dhvanit
Fujiwara, Yoshihiro
Yamauchi, Taro
author_facet Tanaka, Masato
Sake, Naveen
Kim, Dae-Geun
Arataki, Shinya
Desai, Dhvanit
Fujiwara, Yoshihiro
Yamauchi, Taro
author_sort Tanaka, Masato
collection PubMed
description Study design: Technical note. Objectives: To present a novel C-arm-free technique guided by navigation to insert and place a C1 lateral mass screw. Background and Objectives: Atlantoaxial subluxation (AAS) is a relatively common sequelae in patients with rheumatoid arthritis (RA) and upper cervical trauma. If they present with severe symptoms, surgical intervention such as posterior fusion is indicated. The established treatment for AAS is fixation with a C1 lateral mass screw and C2 pedicle screw (modified Goel technique) to achieve bony fusion. However, this technique requires fluoroscopy for C1 screw insertion. To avoid exposing the operating team to radiation, we present here a novel C-arm-free C1 lateral mass screw insertion technique for AAS. Materials and Methods: A 67-year-old man was referred to our hospital with neck pain, quadriparesis, and clumsiness and numbness of both upper and lower limbs. He had undergone C3–6 posterior fusion previously in another hospital. In physical examination, he had severe muscle weakness of bilateral upper limbs and hypoesthesia of all four limbs. He had hyper-reflexia of bilateral lower limbs and pollakiuria. His Japanese orthopedic score was 8 points out of 17. Preoperative radiograms showed AAS with an atlantodental interval (ADI) of 7 mm. MRI indicated retro-odontoid pseudotumor and severe spinal cord compression at the C1–2 level. The patient underwent posterior atlantoaxial fixation under navigation guidance. To prevent epidural bleeding during the insertion and placement of a C1 lateral mass screw, we have here defined a novel screw insertion technique. Results: The surgical time was clocked as 127 min and blood loss was 100 mL. There were no complications per-operatively or in the postoperative period. The patient showed almost full recovery (JOA 16/17) at two months follow-up and a solid bony fusion was noticed in the radiograms at one year follow-up. Conclusions: This novel surgical procedure and C1 lateral mas screw placement technique is a practical and safe method in recent advances of AAS treatment. Procedurally, the technique helps prevent epidural bleeding from the screw entry point and also allows for proper C1 screw insertion under navigation guidance without exposing surgeons and staff to the risk of fluoroscopic radiation.
format Online
Article
Text
id pubmed-9865610
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-98656102023-01-22 Innovative C-Arm-Free Navigation Technique for Posterior Spinal Fixation for Atlantoaxial Subluxation: A Technical Note Tanaka, Masato Sake, Naveen Kim, Dae-Geun Arataki, Shinya Desai, Dhvanit Fujiwara, Yoshihiro Yamauchi, Taro Medicina (Kaunas) Technical Note Study design: Technical note. Objectives: To present a novel C-arm-free technique guided by navigation to insert and place a C1 lateral mass screw. Background and Objectives: Atlantoaxial subluxation (AAS) is a relatively common sequelae in patients with rheumatoid arthritis (RA) and upper cervical trauma. If they present with severe symptoms, surgical intervention such as posterior fusion is indicated. The established treatment for AAS is fixation with a C1 lateral mass screw and C2 pedicle screw (modified Goel technique) to achieve bony fusion. However, this technique requires fluoroscopy for C1 screw insertion. To avoid exposing the operating team to radiation, we present here a novel C-arm-free C1 lateral mass screw insertion technique for AAS. Materials and Methods: A 67-year-old man was referred to our hospital with neck pain, quadriparesis, and clumsiness and numbness of both upper and lower limbs. He had undergone C3–6 posterior fusion previously in another hospital. In physical examination, he had severe muscle weakness of bilateral upper limbs and hypoesthesia of all four limbs. He had hyper-reflexia of bilateral lower limbs and pollakiuria. His Japanese orthopedic score was 8 points out of 17. Preoperative radiograms showed AAS with an atlantodental interval (ADI) of 7 mm. MRI indicated retro-odontoid pseudotumor and severe spinal cord compression at the C1–2 level. The patient underwent posterior atlantoaxial fixation under navigation guidance. To prevent epidural bleeding during the insertion and placement of a C1 lateral mass screw, we have here defined a novel screw insertion technique. Results: The surgical time was clocked as 127 min and blood loss was 100 mL. There were no complications per-operatively or in the postoperative period. The patient showed almost full recovery (JOA 16/17) at two months follow-up and a solid bony fusion was noticed in the radiograms at one year follow-up. Conclusions: This novel surgical procedure and C1 lateral mas screw placement technique is a practical and safe method in recent advances of AAS treatment. Procedurally, the technique helps prevent epidural bleeding from the screw entry point and also allows for proper C1 screw insertion under navigation guidance without exposing surgeons and staff to the risk of fluoroscopic radiation. MDPI 2022-12-20 /pmc/articles/PMC9865610/ /pubmed/36676635 http://dx.doi.org/10.3390/medicina59010011 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Technical Note
Tanaka, Masato
Sake, Naveen
Kim, Dae-Geun
Arataki, Shinya
Desai, Dhvanit
Fujiwara, Yoshihiro
Yamauchi, Taro
Innovative C-Arm-Free Navigation Technique for Posterior Spinal Fixation for Atlantoaxial Subluxation: A Technical Note
title Innovative C-Arm-Free Navigation Technique for Posterior Spinal Fixation for Atlantoaxial Subluxation: A Technical Note
title_full Innovative C-Arm-Free Navigation Technique for Posterior Spinal Fixation for Atlantoaxial Subluxation: A Technical Note
title_fullStr Innovative C-Arm-Free Navigation Technique for Posterior Spinal Fixation for Atlantoaxial Subluxation: A Technical Note
title_full_unstemmed Innovative C-Arm-Free Navigation Technique for Posterior Spinal Fixation for Atlantoaxial Subluxation: A Technical Note
title_short Innovative C-Arm-Free Navigation Technique for Posterior Spinal Fixation for Atlantoaxial Subluxation: A Technical Note
title_sort innovative c-arm-free navigation technique for posterior spinal fixation for atlantoaxial subluxation: a technical note
topic Technical Note
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9865610/
https://www.ncbi.nlm.nih.gov/pubmed/36676635
http://dx.doi.org/10.3390/medicina59010011
work_keys_str_mv AT tanakamasato innovativecarmfreenavigationtechniqueforposteriorspinalfixationforatlantoaxialsubluxationatechnicalnote
AT sakenaveen innovativecarmfreenavigationtechniqueforposteriorspinalfixationforatlantoaxialsubluxationatechnicalnote
AT kimdaegeun innovativecarmfreenavigationtechniqueforposteriorspinalfixationforatlantoaxialsubluxationatechnicalnote
AT aratakishinya innovativecarmfreenavigationtechniqueforposteriorspinalfixationforatlantoaxialsubluxationatechnicalnote
AT desaidhvanit innovativecarmfreenavigationtechniqueforposteriorspinalfixationforatlantoaxialsubluxationatechnicalnote
AT fujiwarayoshihiro innovativecarmfreenavigationtechniqueforposteriorspinalfixationforatlantoaxialsubluxationatechnicalnote
AT yamauchitaro innovativecarmfreenavigationtechniqueforposteriorspinalfixationforatlantoaxialsubluxationatechnicalnote