Cargando…

Dosimetric Study of Heat-Treated Calcium–Aluminum–Silicon Borate Dosimeter for Diagnostic Radiology Applications

The production of thermoluminescence (TL) dosimeters fabricated from B(2)O(3)-CaF(2)-Al(2)O(3)-SiO(2) doped with Cu and Pr for use in diagnostic radiology is the main goal of this research. The TL samples were synthesized via the melt-quench technique processed by melting the mixture at 1200 °C for...

Descripción completa

Detalles Bibliográficos
Autores principales: Algain, Ibrahim, Arib, Mehenna, Al-Said, Said A. Farha, Donya, Hossam
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9865755/
https://www.ncbi.nlm.nih.gov/pubmed/36679808
http://dx.doi.org/10.3390/s23021011
_version_ 1784875917733003264
author Algain, Ibrahim
Arib, Mehenna
Al-Said, Said A. Farha
Donya, Hossam
author_facet Algain, Ibrahim
Arib, Mehenna
Al-Said, Said A. Farha
Donya, Hossam
author_sort Algain, Ibrahim
collection PubMed
description The production of thermoluminescence (TL) dosimeters fabricated from B(2)O(3)-CaF(2)-Al(2)O(3)-SiO(2) doped with Cu and Pr for use in diagnostic radiology is the main goal of this research. The TL samples were synthesized via the melt-quench technique processed by melting the mixture at 1200 °C for 1 h, and, after cooling, the sample thus created was divided into two samples and retreated by heating for 2 h (referred to as TLV30) and for 15 h (referred to as TLV17). SEM and EDS analyses were performed on the TL samples to confirm the preparation process and to investigate the effects of irradiation dosimetry on the TL samples. Furthermore, the TL samples were irradiated with γ-rays using a 450 Ci (137)Cs irradiator and variable X-ray beams (5–70 mGy). Two important diagnostic radiology applications were considered: CT (6–24 mGy) and mammography (2.72–10.8 mGy). Important dosimetric properties, such as the glow curves, reproducibility, dose–response linearity, energy dependence, minimum dose detectability and fading, were investigated for the synthetized samples (TLV17 and TLV30), the results of which were compared with the Harshaw TLD-100. The TLV17 dosimeter showed higher sensitivity than TLV30 in all applied irradiation procedures. The dose–response linearity coefficients of determination R(2) for TLV17 were higher than TLD-100 and TLV30 in some applications and were almost equal in others. The reproducibility results of TLV17, TLV30 and TLD-100 were less than 5%, which is acceptable. On the other hand, the results of the fading investigations showed that, in general, TLV17 showed less fading than TLV30. Both samples showed a significant decrease in this regard after the first day, and then the signal variation became essentially stable though with a slight decrease until the eighth day. Therefore, it is recommended to read the TL dosimeters after 24 h, as with TLD-100. The SEM images confirmed the existence of crystallization, whilst the EDS spectra confirmed the presence of the elements used for preparation. Furthermore, we noticed that TLV17 had grown dense crystals that were larger in size compared to those of TLV30, which explains the higher sensitivity in TLV17. Overall, despite the fading, TLV17 showed greater radiation sensitivity and dose–response linearity compared with TLD-100. The synthetized TL samples showed their suitability for use as dosimeters in diagnostic radiology radiation dosimetry.
format Online
Article
Text
id pubmed-9865755
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-98657552023-01-22 Dosimetric Study of Heat-Treated Calcium–Aluminum–Silicon Borate Dosimeter for Diagnostic Radiology Applications Algain, Ibrahim Arib, Mehenna Al-Said, Said A. Farha Donya, Hossam Sensors (Basel) Article The production of thermoluminescence (TL) dosimeters fabricated from B(2)O(3)-CaF(2)-Al(2)O(3)-SiO(2) doped with Cu and Pr for use in diagnostic radiology is the main goal of this research. The TL samples were synthesized via the melt-quench technique processed by melting the mixture at 1200 °C for 1 h, and, after cooling, the sample thus created was divided into two samples and retreated by heating for 2 h (referred to as TLV30) and for 15 h (referred to as TLV17). SEM and EDS analyses were performed on the TL samples to confirm the preparation process and to investigate the effects of irradiation dosimetry on the TL samples. Furthermore, the TL samples were irradiated with γ-rays using a 450 Ci (137)Cs irradiator and variable X-ray beams (5–70 mGy). Two important diagnostic radiology applications were considered: CT (6–24 mGy) and mammography (2.72–10.8 mGy). Important dosimetric properties, such as the glow curves, reproducibility, dose–response linearity, energy dependence, minimum dose detectability and fading, were investigated for the synthetized samples (TLV17 and TLV30), the results of which were compared with the Harshaw TLD-100. The TLV17 dosimeter showed higher sensitivity than TLV30 in all applied irradiation procedures. The dose–response linearity coefficients of determination R(2) for TLV17 were higher than TLD-100 and TLV30 in some applications and were almost equal in others. The reproducibility results of TLV17, TLV30 and TLD-100 were less than 5%, which is acceptable. On the other hand, the results of the fading investigations showed that, in general, TLV17 showed less fading than TLV30. Both samples showed a significant decrease in this regard after the first day, and then the signal variation became essentially stable though with a slight decrease until the eighth day. Therefore, it is recommended to read the TL dosimeters after 24 h, as with TLD-100. The SEM images confirmed the existence of crystallization, whilst the EDS spectra confirmed the presence of the elements used for preparation. Furthermore, we noticed that TLV17 had grown dense crystals that were larger in size compared to those of TLV30, which explains the higher sensitivity in TLV17. Overall, despite the fading, TLV17 showed greater radiation sensitivity and dose–response linearity compared with TLD-100. The synthetized TL samples showed their suitability for use as dosimeters in diagnostic radiology radiation dosimetry. MDPI 2023-01-16 /pmc/articles/PMC9865755/ /pubmed/36679808 http://dx.doi.org/10.3390/s23021011 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Algain, Ibrahim
Arib, Mehenna
Al-Said, Said A. Farha
Donya, Hossam
Dosimetric Study of Heat-Treated Calcium–Aluminum–Silicon Borate Dosimeter for Diagnostic Radiology Applications
title Dosimetric Study of Heat-Treated Calcium–Aluminum–Silicon Borate Dosimeter for Diagnostic Radiology Applications
title_full Dosimetric Study of Heat-Treated Calcium–Aluminum–Silicon Borate Dosimeter for Diagnostic Radiology Applications
title_fullStr Dosimetric Study of Heat-Treated Calcium–Aluminum–Silicon Borate Dosimeter for Diagnostic Radiology Applications
title_full_unstemmed Dosimetric Study of Heat-Treated Calcium–Aluminum–Silicon Borate Dosimeter for Diagnostic Radiology Applications
title_short Dosimetric Study of Heat-Treated Calcium–Aluminum–Silicon Borate Dosimeter for Diagnostic Radiology Applications
title_sort dosimetric study of heat-treated calcium–aluminum–silicon borate dosimeter for diagnostic radiology applications
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9865755/
https://www.ncbi.nlm.nih.gov/pubmed/36679808
http://dx.doi.org/10.3390/s23021011
work_keys_str_mv AT algainibrahim dosimetricstudyofheattreatedcalciumaluminumsiliconboratedosimeterfordiagnosticradiologyapplications
AT aribmehenna dosimetricstudyofheattreatedcalciumaluminumsiliconboratedosimeterfordiagnosticradiologyapplications
AT alsaidsaidafarha dosimetricstudyofheattreatedcalciumaluminumsiliconboratedosimeterfordiagnosticradiologyapplications
AT donyahossam dosimetricstudyofheattreatedcalciumaluminumsiliconboratedosimeterfordiagnosticradiologyapplications