Matching the Optimal Operating Mode of Polydimethylsiloxane Check Valves by Tuning the Resonant Frequency of the Resonator in a Piezoelectric Pump for Improved Output Performance
This paper proposes to improve the output performance of a piezoelectric pump by matching the resonant frequency of the resonator to the optimal operating mode of bridge-type polydimethylsiloxane (PDMS) check valves. Simulation analyses reveal that the side-curling mode of the PDMS valve is conduciv...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9866841/ https://www.ncbi.nlm.nih.gov/pubmed/36677076 http://dx.doi.org/10.3390/mi14010015 |
_version_ | 1784876192062504960 |
---|---|
author | Chen, Jian Meng, Fanci Feng, Zihan Gao, Wenzhi Liu, Changhai Zeng, Yishan |
author_facet | Chen, Jian Meng, Fanci Feng, Zihan Gao, Wenzhi Liu, Changhai Zeng, Yishan |
author_sort | Chen, Jian |
collection | PubMed |
description | This paper proposes to improve the output performance of a piezoelectric pump by matching the resonant frequency of the resonator to the optimal operating mode of bridge-type polydimethylsiloxane (PDMS) check valves. Simulation analyses reveal that the side-curling mode of the PDMS valve is conducive to liquid flow and exhibits a faster frequency response compared with the first bending mode. The first bending resonant frequency of a beam-type piezoelectric resonator was tuned close to the side-curling mode of the PDMS valve by adjusting the weight of two mass blocks installed on both ends of the resonator, so that both the resonator and the valve could work at their best conditions. Experiments were conducted on a detachable prototype piezoelectric pump using PDMS valves with three different lengths. The results confirm that the peak flowrate at the resonant point of the pump reaches its maximum when the resonant frequencies between the resonator and the valve are matched. Maximum peak flowrates of 88 mL/min, 72 mL/min and 70 mL/min were achieved at 722 Hz, 761 Hz and 789 Hz, respectively, for diaphragm pumps using five-, four- and three-inlet-hole PDMS valves, under a driving voltage of 300 V(pp). |
format | Online Article Text |
id | pubmed-9866841 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-98668412023-01-22 Matching the Optimal Operating Mode of Polydimethylsiloxane Check Valves by Tuning the Resonant Frequency of the Resonator in a Piezoelectric Pump for Improved Output Performance Chen, Jian Meng, Fanci Feng, Zihan Gao, Wenzhi Liu, Changhai Zeng, Yishan Micromachines (Basel) Article This paper proposes to improve the output performance of a piezoelectric pump by matching the resonant frequency of the resonator to the optimal operating mode of bridge-type polydimethylsiloxane (PDMS) check valves. Simulation analyses reveal that the side-curling mode of the PDMS valve is conducive to liquid flow and exhibits a faster frequency response compared with the first bending mode. The first bending resonant frequency of a beam-type piezoelectric resonator was tuned close to the side-curling mode of the PDMS valve by adjusting the weight of two mass blocks installed on both ends of the resonator, so that both the resonator and the valve could work at their best conditions. Experiments were conducted on a detachable prototype piezoelectric pump using PDMS valves with three different lengths. The results confirm that the peak flowrate at the resonant point of the pump reaches its maximum when the resonant frequencies between the resonator and the valve are matched. Maximum peak flowrates of 88 mL/min, 72 mL/min and 70 mL/min were achieved at 722 Hz, 761 Hz and 789 Hz, respectively, for diaphragm pumps using five-, four- and three-inlet-hole PDMS valves, under a driving voltage of 300 V(pp). MDPI 2022-12-21 /pmc/articles/PMC9866841/ /pubmed/36677076 http://dx.doi.org/10.3390/mi14010015 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Chen, Jian Meng, Fanci Feng, Zihan Gao, Wenzhi Liu, Changhai Zeng, Yishan Matching the Optimal Operating Mode of Polydimethylsiloxane Check Valves by Tuning the Resonant Frequency of the Resonator in a Piezoelectric Pump for Improved Output Performance |
title | Matching the Optimal Operating Mode of Polydimethylsiloxane Check Valves by Tuning the Resonant Frequency of the Resonator in a Piezoelectric Pump for Improved Output Performance |
title_full | Matching the Optimal Operating Mode of Polydimethylsiloxane Check Valves by Tuning the Resonant Frequency of the Resonator in a Piezoelectric Pump for Improved Output Performance |
title_fullStr | Matching the Optimal Operating Mode of Polydimethylsiloxane Check Valves by Tuning the Resonant Frequency of the Resonator in a Piezoelectric Pump for Improved Output Performance |
title_full_unstemmed | Matching the Optimal Operating Mode of Polydimethylsiloxane Check Valves by Tuning the Resonant Frequency of the Resonator in a Piezoelectric Pump for Improved Output Performance |
title_short | Matching the Optimal Operating Mode of Polydimethylsiloxane Check Valves by Tuning the Resonant Frequency of the Resonator in a Piezoelectric Pump for Improved Output Performance |
title_sort | matching the optimal operating mode of polydimethylsiloxane check valves by tuning the resonant frequency of the resonator in a piezoelectric pump for improved output performance |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9866841/ https://www.ncbi.nlm.nih.gov/pubmed/36677076 http://dx.doi.org/10.3390/mi14010015 |
work_keys_str_mv | AT chenjian matchingtheoptimaloperatingmodeofpolydimethylsiloxanecheckvalvesbytuningtheresonantfrequencyoftheresonatorinapiezoelectricpumpforimprovedoutputperformance AT mengfanci matchingtheoptimaloperatingmodeofpolydimethylsiloxanecheckvalvesbytuningtheresonantfrequencyoftheresonatorinapiezoelectricpumpforimprovedoutputperformance AT fengzihan matchingtheoptimaloperatingmodeofpolydimethylsiloxanecheckvalvesbytuningtheresonantfrequencyoftheresonatorinapiezoelectricpumpforimprovedoutputperformance AT gaowenzhi matchingtheoptimaloperatingmodeofpolydimethylsiloxanecheckvalvesbytuningtheresonantfrequencyoftheresonatorinapiezoelectricpumpforimprovedoutputperformance AT liuchanghai matchingtheoptimaloperatingmodeofpolydimethylsiloxanecheckvalvesbytuningtheresonantfrequencyoftheresonatorinapiezoelectricpumpforimprovedoutputperformance AT zengyishan matchingtheoptimaloperatingmodeofpolydimethylsiloxanecheckvalvesbytuningtheresonantfrequencyoftheresonatorinapiezoelectricpumpforimprovedoutputperformance |