Cargando…

QuEChERS-Based Approach to the Extraction of Five Calcium Channel Blockers from Plasma Determined by UPLC-MS/MS

Here, a QuEChERS (quick, easy, cheap, effective, rugged, and safe) pretreatment method was combined with UPLC-MS/MS to facilitate the rapid and reliable simultaneous detection of five calcium channel blockers (CCBs) in human plasma. For this approach, samples were treated with 1 mL of acetonitrile,...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhao, Tingting, Jiang, Wen, Zhen, Xiaolan, Jin, Chengcheng, Zhang, Yifan, Li, Hui
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9866929/
https://www.ncbi.nlm.nih.gov/pubmed/36677729
http://dx.doi.org/10.3390/molecules28020671
_version_ 1784876214367813632
author Zhao, Tingting
Jiang, Wen
Zhen, Xiaolan
Jin, Chengcheng
Zhang, Yifan
Li, Hui
author_facet Zhao, Tingting
Jiang, Wen
Zhen, Xiaolan
Jin, Chengcheng
Zhang, Yifan
Li, Hui
author_sort Zhao, Tingting
collection PubMed
description Here, a QuEChERS (quick, easy, cheap, effective, rugged, and safe) pretreatment method was combined with UPLC-MS/MS to facilitate the rapid and reliable simultaneous detection of five calcium channel blockers (CCBs) in human plasma. For this approach, samples were treated with 1 mL of acetonitrile, 350 mg of magnesium sulfate, and 70 mg of PSA adsorbent prior to centrifugation. Supernatants then underwent gradient elution for 8 min with an Agilent C18 column using an acetonitrile-water solution supplemented with 5 mmol⋅L(−1) of ammonium acetate. This technique exhibited a good linear response in the 1–800 ng⋅mL(−1) range for the analyzed drugs, with an R(2)≥ 0.9921, an accuracy of 87.54–113.05%, a matrix effect (ME) of 91.21–116.39%, a precision of 0.19–11.64%, and stability of no more than 10.05%. This time-saving QuEChERS reagent-based pretreatment technique thus allowed for the simultaneous and accurate detection of five CCBs in human plasma samples, providing a promising new basis for therapeutic drug monitoring in patients with hypertension.
format Online
Article
Text
id pubmed-9866929
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-98669292023-01-22 QuEChERS-Based Approach to the Extraction of Five Calcium Channel Blockers from Plasma Determined by UPLC-MS/MS Zhao, Tingting Jiang, Wen Zhen, Xiaolan Jin, Chengcheng Zhang, Yifan Li, Hui Molecules Article Here, a QuEChERS (quick, easy, cheap, effective, rugged, and safe) pretreatment method was combined with UPLC-MS/MS to facilitate the rapid and reliable simultaneous detection of five calcium channel blockers (CCBs) in human plasma. For this approach, samples were treated with 1 mL of acetonitrile, 350 mg of magnesium sulfate, and 70 mg of PSA adsorbent prior to centrifugation. Supernatants then underwent gradient elution for 8 min with an Agilent C18 column using an acetonitrile-water solution supplemented with 5 mmol⋅L(−1) of ammonium acetate. This technique exhibited a good linear response in the 1–800 ng⋅mL(−1) range for the analyzed drugs, with an R(2)≥ 0.9921, an accuracy of 87.54–113.05%, a matrix effect (ME) of 91.21–116.39%, a precision of 0.19–11.64%, and stability of no more than 10.05%. This time-saving QuEChERS reagent-based pretreatment technique thus allowed for the simultaneous and accurate detection of five CCBs in human plasma samples, providing a promising new basis for therapeutic drug monitoring in patients with hypertension. MDPI 2023-01-09 /pmc/articles/PMC9866929/ /pubmed/36677729 http://dx.doi.org/10.3390/molecules28020671 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Zhao, Tingting
Jiang, Wen
Zhen, Xiaolan
Jin, Chengcheng
Zhang, Yifan
Li, Hui
QuEChERS-Based Approach to the Extraction of Five Calcium Channel Blockers from Plasma Determined by UPLC-MS/MS
title QuEChERS-Based Approach to the Extraction of Five Calcium Channel Blockers from Plasma Determined by UPLC-MS/MS
title_full QuEChERS-Based Approach to the Extraction of Five Calcium Channel Blockers from Plasma Determined by UPLC-MS/MS
title_fullStr QuEChERS-Based Approach to the Extraction of Five Calcium Channel Blockers from Plasma Determined by UPLC-MS/MS
title_full_unstemmed QuEChERS-Based Approach to the Extraction of Five Calcium Channel Blockers from Plasma Determined by UPLC-MS/MS
title_short QuEChERS-Based Approach to the Extraction of Five Calcium Channel Blockers from Plasma Determined by UPLC-MS/MS
title_sort quechers-based approach to the extraction of five calcium channel blockers from plasma determined by uplc-ms/ms
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9866929/
https://www.ncbi.nlm.nih.gov/pubmed/36677729
http://dx.doi.org/10.3390/molecules28020671
work_keys_str_mv AT zhaotingting quechersbasedapproachtotheextractionoffivecalciumchannelblockersfromplasmadeterminedbyuplcmsms
AT jiangwen quechersbasedapproachtotheextractionoffivecalciumchannelblockersfromplasmadeterminedbyuplcmsms
AT zhenxiaolan quechersbasedapproachtotheextractionoffivecalciumchannelblockersfromplasmadeterminedbyuplcmsms
AT jinchengcheng quechersbasedapproachtotheextractionoffivecalciumchannelblockersfromplasmadeterminedbyuplcmsms
AT zhangyifan quechersbasedapproachtotheextractionoffivecalciumchannelblockersfromplasmadeterminedbyuplcmsms
AT lihui quechersbasedapproachtotheextractionoffivecalciumchannelblockersfromplasmadeterminedbyuplcmsms