Cargando…

Consideration of Commercially Available Hepatocytes as Cell Sources for Liver-Microphysiological Systems by Comparing Liver Characteristics

In recent years, microphysiological systems (MPS) have been developed to shorten the test period and reduce animal experiments for drug development. We examined cell sources for the liver-MPS, i.e., MPS mimicking liver function. For liver-MPS, liver-like cells with high liver functions are required....

Descripción completa

Detalles Bibliográficos
Autores principales: Horiuchi, Shinichiro, Kuroda, Yukie, Komizu, Yuji, Ishida, Seiichi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9867117/
https://www.ncbi.nlm.nih.gov/pubmed/36678684
http://dx.doi.org/10.3390/pharmaceutics15010055
_version_ 1784876262794199040
author Horiuchi, Shinichiro
Kuroda, Yukie
Komizu, Yuji
Ishida, Seiichi
author_facet Horiuchi, Shinichiro
Kuroda, Yukie
Komizu, Yuji
Ishida, Seiichi
author_sort Horiuchi, Shinichiro
collection PubMed
description In recent years, microphysiological systems (MPS) have been developed to shorten the test period and reduce animal experiments for drug development. We examined cell sources for the liver-MPS, i.e., MPS mimicking liver function. For liver-MPS, liver-like cells with high liver functions are required. Cryo-preserved hepatocytes (cryoheps), the gold standard hepatocytes for in vitro drug development, present several disadvantages, including differences between lots due to individual donor variations or a limited cell supply from the same donor. As such, alternatives for cryoheps are sought. Hepatocyte-like cells derived from human induced pluripotent stem cells (hiPSC-Heps), hepatocytes derived from liver-humanized mice (PXB-cells), and human liver cancer cells (HepG2 cells) were examined as source candidates for liver-MPS. Gene expression levels of the major cytochrome P450 of hiPSC-Heps, PXB cells, and HepG2 cells were compared with 22 lots of cryoheps, and the activities of hiPSC-Heps were compared with 8 lots of cryopreserved hepatocytes. A focused DNA microarray was used for the global gene analysis of the liver-like characteristics of hiPSC-Heps, PXB-cells, cryoheps, and HepG2 cells. Gene expression data from the focused microarray were analyzed by principal component analysis, hierarchical clustering, and enrichment analysis. The results indicated the characteristics of individual hepatocyte cell source and raised their consideration points as an alternative cell source candidate for liver-MPS. The study contributes to the repetitive utilization of a robust in vitro hepatic assay system over long periods with stable functionality.
format Online
Article
Text
id pubmed-9867117
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-98671172023-01-22 Consideration of Commercially Available Hepatocytes as Cell Sources for Liver-Microphysiological Systems by Comparing Liver Characteristics Horiuchi, Shinichiro Kuroda, Yukie Komizu, Yuji Ishida, Seiichi Pharmaceutics Article In recent years, microphysiological systems (MPS) have been developed to shorten the test period and reduce animal experiments for drug development. We examined cell sources for the liver-MPS, i.e., MPS mimicking liver function. For liver-MPS, liver-like cells with high liver functions are required. Cryo-preserved hepatocytes (cryoheps), the gold standard hepatocytes for in vitro drug development, present several disadvantages, including differences between lots due to individual donor variations or a limited cell supply from the same donor. As such, alternatives for cryoheps are sought. Hepatocyte-like cells derived from human induced pluripotent stem cells (hiPSC-Heps), hepatocytes derived from liver-humanized mice (PXB-cells), and human liver cancer cells (HepG2 cells) were examined as source candidates for liver-MPS. Gene expression levels of the major cytochrome P450 of hiPSC-Heps, PXB cells, and HepG2 cells were compared with 22 lots of cryoheps, and the activities of hiPSC-Heps were compared with 8 lots of cryopreserved hepatocytes. A focused DNA microarray was used for the global gene analysis of the liver-like characteristics of hiPSC-Heps, PXB-cells, cryoheps, and HepG2 cells. Gene expression data from the focused microarray were analyzed by principal component analysis, hierarchical clustering, and enrichment analysis. The results indicated the characteristics of individual hepatocyte cell source and raised their consideration points as an alternative cell source candidate for liver-MPS. The study contributes to the repetitive utilization of a robust in vitro hepatic assay system over long periods with stable functionality. MDPI 2022-12-24 /pmc/articles/PMC9867117/ /pubmed/36678684 http://dx.doi.org/10.3390/pharmaceutics15010055 Text en © 2022 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Horiuchi, Shinichiro
Kuroda, Yukie
Komizu, Yuji
Ishida, Seiichi
Consideration of Commercially Available Hepatocytes as Cell Sources for Liver-Microphysiological Systems by Comparing Liver Characteristics
title Consideration of Commercially Available Hepatocytes as Cell Sources for Liver-Microphysiological Systems by Comparing Liver Characteristics
title_full Consideration of Commercially Available Hepatocytes as Cell Sources for Liver-Microphysiological Systems by Comparing Liver Characteristics
title_fullStr Consideration of Commercially Available Hepatocytes as Cell Sources for Liver-Microphysiological Systems by Comparing Liver Characteristics
title_full_unstemmed Consideration of Commercially Available Hepatocytes as Cell Sources for Liver-Microphysiological Systems by Comparing Liver Characteristics
title_short Consideration of Commercially Available Hepatocytes as Cell Sources for Liver-Microphysiological Systems by Comparing Liver Characteristics
title_sort consideration of commercially available hepatocytes as cell sources for liver-microphysiological systems by comparing liver characteristics
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9867117/
https://www.ncbi.nlm.nih.gov/pubmed/36678684
http://dx.doi.org/10.3390/pharmaceutics15010055
work_keys_str_mv AT horiuchishinichiro considerationofcommerciallyavailablehepatocytesascellsourcesforlivermicrophysiologicalsystemsbycomparinglivercharacteristics
AT kurodayukie considerationofcommerciallyavailablehepatocytesascellsourcesforlivermicrophysiologicalsystemsbycomparinglivercharacteristics
AT komizuyuji considerationofcommerciallyavailablehepatocytesascellsourcesforlivermicrophysiologicalsystemsbycomparinglivercharacteristics
AT ishidaseiichi considerationofcommerciallyavailablehepatocytesascellsourcesforlivermicrophysiologicalsystemsbycomparinglivercharacteristics