Fabrication of Mechanically Enhanced, Suturable, Fibrous Hydrogel Membranes
Poly(vinyl-alcohol) hydrogels have already been successfully utilised as drug carrier systems and tissue engineering scaffolds. However, lacking mechanical strength and suturability hinders any prospects for clinical and surgical applications. The objective of this work was to fabricate mechanically...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9867240/ https://www.ncbi.nlm.nih.gov/pubmed/36676923 http://dx.doi.org/10.3390/membranes13010116 |
_version_ | 1784876293109579776 |
---|---|
author | Voniatis, Constantinos Závoti, Olivér Manikion, Kenigen Budavári, Bálint Hajdu, Angela Jedlovszky |
author_facet | Voniatis, Constantinos Závoti, Olivér Manikion, Kenigen Budavári, Bálint Hajdu, Angela Jedlovszky |
author_sort | Voniatis, Constantinos |
collection | PubMed |
description | Poly(vinyl-alcohol) hydrogels have already been successfully utilised as drug carrier systems and tissue engineering scaffolds. However, lacking mechanical strength and suturability hinders any prospects for clinical and surgical applications. The objective of this work was to fabricate mechanically robust PVA membranes, which could also withstand surgical manipulation and suturing. Electrospun membranes and control hydrogels were produced with 61 kDa PVA. Using a high-speed rotating cylindrical collector, we achieved fibre alignment (fibre diameter: 300 ± 50 nm). Subsequently, we created multilayered samples with different orientations to achieve multidirectional reinforcement. Finally, utilising glutaraldehyde as a cross-linker, we created insoluble fibrous-hydrogel membranes. Mechanical studies were performed, confirming a fourfold increase in the specific loading capacities (from 0.21 to 0.84 Nm(2)/g) in the case of the monolayer samples. The multilayered membranes exhibited increased resistance from both horizontal and vertical directions, which varies according to the specific arrangement. Finally, the cross-linked fibrous hydrogel samples not only exhibited specific loading capacities significantly higher than their counterpart bulk hydrogels but successfully withstood suturing. Although cross-linking optimisation and animal experiments are required, these membranes have great prospects as alternatives to current surgical meshes, while the methodology could also be applied in other systems as well. |
format | Online Article Text |
id | pubmed-9867240 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-98672402023-01-22 Fabrication of Mechanically Enhanced, Suturable, Fibrous Hydrogel Membranes Voniatis, Constantinos Závoti, Olivér Manikion, Kenigen Budavári, Bálint Hajdu, Angela Jedlovszky Membranes (Basel) Article Poly(vinyl-alcohol) hydrogels have already been successfully utilised as drug carrier systems and tissue engineering scaffolds. However, lacking mechanical strength and suturability hinders any prospects for clinical and surgical applications. The objective of this work was to fabricate mechanically robust PVA membranes, which could also withstand surgical manipulation and suturing. Electrospun membranes and control hydrogels were produced with 61 kDa PVA. Using a high-speed rotating cylindrical collector, we achieved fibre alignment (fibre diameter: 300 ± 50 nm). Subsequently, we created multilayered samples with different orientations to achieve multidirectional reinforcement. Finally, utilising glutaraldehyde as a cross-linker, we created insoluble fibrous-hydrogel membranes. Mechanical studies were performed, confirming a fourfold increase in the specific loading capacities (from 0.21 to 0.84 Nm(2)/g) in the case of the monolayer samples. The multilayered membranes exhibited increased resistance from both horizontal and vertical directions, which varies according to the specific arrangement. Finally, the cross-linked fibrous hydrogel samples not only exhibited specific loading capacities significantly higher than their counterpart bulk hydrogels but successfully withstood suturing. Although cross-linking optimisation and animal experiments are required, these membranes have great prospects as alternatives to current surgical meshes, while the methodology could also be applied in other systems as well. MDPI 2023-01-16 /pmc/articles/PMC9867240/ /pubmed/36676923 http://dx.doi.org/10.3390/membranes13010116 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Voniatis, Constantinos Závoti, Olivér Manikion, Kenigen Budavári, Bálint Hajdu, Angela Jedlovszky Fabrication of Mechanically Enhanced, Suturable, Fibrous Hydrogel Membranes |
title | Fabrication of Mechanically Enhanced, Suturable, Fibrous Hydrogel Membranes |
title_full | Fabrication of Mechanically Enhanced, Suturable, Fibrous Hydrogel Membranes |
title_fullStr | Fabrication of Mechanically Enhanced, Suturable, Fibrous Hydrogel Membranes |
title_full_unstemmed | Fabrication of Mechanically Enhanced, Suturable, Fibrous Hydrogel Membranes |
title_short | Fabrication of Mechanically Enhanced, Suturable, Fibrous Hydrogel Membranes |
title_sort | fabrication of mechanically enhanced, suturable, fibrous hydrogel membranes |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9867240/ https://www.ncbi.nlm.nih.gov/pubmed/36676923 http://dx.doi.org/10.3390/membranes13010116 |
work_keys_str_mv | AT voniatisconstantinos fabricationofmechanicallyenhancedsuturablefibroushydrogelmembranes AT zavotioliver fabricationofmechanicallyenhancedsuturablefibroushydrogelmembranes AT manikionkenigen fabricationofmechanicallyenhancedsuturablefibroushydrogelmembranes AT budavaribalint fabricationofmechanicallyenhancedsuturablefibroushydrogelmembranes AT hajduangelajedlovszky fabricationofmechanicallyenhancedsuturablefibroushydrogelmembranes |