Cargando…
Comparison of five different methodologies for evaluating ankle–foot orthosis stiffness
BACKGROUND: The mechanical properties of an ankle–foot orthosis (AFO) play an important role in the gait mechanics of the end user. However, testing methodologies for evaluating these mechanical properties are not standardized. The purpose of this study was to compare five different evaluation frame...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9867850/ https://www.ncbi.nlm.nih.gov/pubmed/36683044 http://dx.doi.org/10.1186/s12984-023-01126-7 |
_version_ | 1784876428480741376 |
---|---|
author | Shuman, Benjamin R. Totah, Deema Gates, Deanna H. Gao, Fan Ries, Andrew J. Russell Esposito, Elizabeth |
author_facet | Shuman, Benjamin R. Totah, Deema Gates, Deanna H. Gao, Fan Ries, Andrew J. Russell Esposito, Elizabeth |
author_sort | Shuman, Benjamin R. |
collection | PubMed |
description | BACKGROUND: The mechanical properties of an ankle–foot orthosis (AFO) play an important role in the gait mechanics of the end user. However, testing methodologies for evaluating these mechanical properties are not standardized. The purpose of this study was to compare five different evaluation frameworks to assess AFO stiffness. METHOD: The same 13 carbon composite AFOs were tested with five different methods. Four previously reported custom test fixtures (the BRUCE, KST, SMApp, and EMPIRE) rotated an AFO into dorsiflexion about a defined axis in the sagittal plane. The fifth method involved quasi-static deflection of AFOs into dorsiflexion by hanging weights (HW) from the footplate. AFO rotational stiffness was calculated as the linear fit of the AFO resistive torque and angular deflection. Differences between methods were assessed using descriptive statistics and a repeated measures Friedman with post-hoc Bonferroni–Holm adjusted Wilcoxon signed-rank tests. RESULTS: There were significant differences in measured AFO stiffnesses between test methods. Specifically, the BRUCE and HW methods measured lower stiffness than both the EMPIRE and the KST. Stiffnesses measured by the SMApp were not significantly different than any test method. Stiffnesses were lowest in the HW method, where motion was not constrained to a single plane. The median difference in absolute AFO stiffness across methods was 1.03 Nm/deg with a range of [0.40 to 2.35] Nm/deg. The median relative percent difference, measured as the range of measured stiffness from the five methods over the average measured stiffness was 62% [range 13% to 156%]. When the HW method was excluded, the four previously reported test fixtures produced a median difference in absolute AFO stiffness of 0.52 [range 0.38 to 2.17] Nm/deg with a relative percent difference between the methods of 27% [range 13% to 89%]. CONCLUSIONS: This study demonstrates the importance of developing mechanical testing standards, similar to those that exist for lower limb prosthetics. Lacking standardization, differences in methodology can result in large differences in measured stiffness, particularly for different constraints on motion. Non-uniform measurement practices may limit the clinical utility of AFO stiffness as a metric in AFO prescription and future research. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12984-023-01126-7. |
format | Online Article Text |
id | pubmed-9867850 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-98678502023-01-23 Comparison of five different methodologies for evaluating ankle–foot orthosis stiffness Shuman, Benjamin R. Totah, Deema Gates, Deanna H. Gao, Fan Ries, Andrew J. Russell Esposito, Elizabeth J Neuroeng Rehabil Research BACKGROUND: The mechanical properties of an ankle–foot orthosis (AFO) play an important role in the gait mechanics of the end user. However, testing methodologies for evaluating these mechanical properties are not standardized. The purpose of this study was to compare five different evaluation frameworks to assess AFO stiffness. METHOD: The same 13 carbon composite AFOs were tested with five different methods. Four previously reported custom test fixtures (the BRUCE, KST, SMApp, and EMPIRE) rotated an AFO into dorsiflexion about a defined axis in the sagittal plane. The fifth method involved quasi-static deflection of AFOs into dorsiflexion by hanging weights (HW) from the footplate. AFO rotational stiffness was calculated as the linear fit of the AFO resistive torque and angular deflection. Differences between methods were assessed using descriptive statistics and a repeated measures Friedman with post-hoc Bonferroni–Holm adjusted Wilcoxon signed-rank tests. RESULTS: There were significant differences in measured AFO stiffnesses between test methods. Specifically, the BRUCE and HW methods measured lower stiffness than both the EMPIRE and the KST. Stiffnesses measured by the SMApp were not significantly different than any test method. Stiffnesses were lowest in the HW method, where motion was not constrained to a single plane. The median difference in absolute AFO stiffness across methods was 1.03 Nm/deg with a range of [0.40 to 2.35] Nm/deg. The median relative percent difference, measured as the range of measured stiffness from the five methods over the average measured stiffness was 62% [range 13% to 156%]. When the HW method was excluded, the four previously reported test fixtures produced a median difference in absolute AFO stiffness of 0.52 [range 0.38 to 2.17] Nm/deg with a relative percent difference between the methods of 27% [range 13% to 89%]. CONCLUSIONS: This study demonstrates the importance of developing mechanical testing standards, similar to those that exist for lower limb prosthetics. Lacking standardization, differences in methodology can result in large differences in measured stiffness, particularly for different constraints on motion. Non-uniform measurement practices may limit the clinical utility of AFO stiffness as a metric in AFO prescription and future research. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12984-023-01126-7. BioMed Central 2023-01-22 /pmc/articles/PMC9867850/ /pubmed/36683044 http://dx.doi.org/10.1186/s12984-023-01126-7 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Shuman, Benjamin R. Totah, Deema Gates, Deanna H. Gao, Fan Ries, Andrew J. Russell Esposito, Elizabeth Comparison of five different methodologies for evaluating ankle–foot orthosis stiffness |
title | Comparison of five different methodologies for evaluating ankle–foot orthosis stiffness |
title_full | Comparison of five different methodologies for evaluating ankle–foot orthosis stiffness |
title_fullStr | Comparison of five different methodologies for evaluating ankle–foot orthosis stiffness |
title_full_unstemmed | Comparison of five different methodologies for evaluating ankle–foot orthosis stiffness |
title_short | Comparison of five different methodologies for evaluating ankle–foot orthosis stiffness |
title_sort | comparison of five different methodologies for evaluating ankle–foot orthosis stiffness |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9867850/ https://www.ncbi.nlm.nih.gov/pubmed/36683044 http://dx.doi.org/10.1186/s12984-023-01126-7 |
work_keys_str_mv | AT shumanbenjaminr comparisonoffivedifferentmethodologiesforevaluatinganklefootorthosisstiffness AT totahdeema comparisonoffivedifferentmethodologiesforevaluatinganklefootorthosisstiffness AT gatesdeannah comparisonoffivedifferentmethodologiesforevaluatinganklefootorthosisstiffness AT gaofan comparisonoffivedifferentmethodologiesforevaluatinganklefootorthosisstiffness AT riesandrewj comparisonoffivedifferentmethodologiesforevaluatinganklefootorthosisstiffness AT russellespositoelizabeth comparisonoffivedifferentmethodologiesforevaluatinganklefootorthosisstiffness |