Cargando…

The role of atria in ventricular fibrillation after continuous-flow left ventricular assist device implantation in ovine model

OBJECTIVES: This study attempted to explore the hemodynamics and potential mechanisms driving pulmonary circulation in status of ventricular fibrillation (VF) following continuous-flow left ventricular assist device (CF-LVAD) implantation. METHODS: An ovine CF-LVAD model was built in small-tailed Ha...

Descripción completa

Detalles Bibliográficos
Autores principales: Yu, Xin-Yi, Shi, Jian-Wei, Rong, Yan-Sheng, Chen, Yuan-Lu, Liu, Tian-Wen, Zang, Yi-Rui, Fu, Ze-An, Zhang, Jie-Min, Han, Zhi-Fu, Liu, Zhi-Gang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9868250/
https://www.ncbi.nlm.nih.gov/pubmed/36698959
http://dx.doi.org/10.3389/fcvm.2022.1000352
_version_ 1784876490686464000
author Yu, Xin-Yi
Shi, Jian-Wei
Rong, Yan-Sheng
Chen, Yuan-Lu
Liu, Tian-Wen
Zang, Yi-Rui
Fu, Ze-An
Zhang, Jie-Min
Han, Zhi-Fu
Liu, Zhi-Gang
author_facet Yu, Xin-Yi
Shi, Jian-Wei
Rong, Yan-Sheng
Chen, Yuan-Lu
Liu, Tian-Wen
Zang, Yi-Rui
Fu, Ze-An
Zhang, Jie-Min
Han, Zhi-Fu
Liu, Zhi-Gang
author_sort Yu, Xin-Yi
collection PubMed
description OBJECTIVES: This study attempted to explore the hemodynamics and potential mechanisms driving pulmonary circulation in status of ventricular fibrillation (VF) following continuous-flow left ventricular assist device (CF-LVAD) implantation. METHODS: An ovine CF-LVAD model was built in small-tailed Han sheep, with the pump speed set as 2,400 rpm. VF was induced following ventricular tachycardia using a temporary pacemaker probe to stimulate the right and left ventricular free walls. The central venous pressure (CVP), pump flow (PF), pulmonary artery flow (PAF) and other major indicators were observed and recorded after VF. RESULTS: Low-flow systemic and pulmonary circulation could be sustained for 60 min under VF with sinus atrial rhythm after CF-LVAD implantation. The CVP gradually increased. The mean PF declined from 1.80 to 1.20 L/min, and the mean PAF decreased from 1.62 L/min to 0.87 L/min. Under VF with atrial fibrillation, the systemic and pulmonary circulation couldn’t be sustained. The CVP jumped from the 5 mmHg baseline to 12 mmHg, the mean PF rapidly decreased from 3.45 L/min to 0.79 L/min, and the PAF declined from 3.94 L/min to 0.77 L/min. CONCLUSION: The atrial rhythm and function might be essential for the circulation maintenance in patients with VF after CF-LVAD implantation.
format Online
Article
Text
id pubmed-9868250
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-98682502023-01-24 The role of atria in ventricular fibrillation after continuous-flow left ventricular assist device implantation in ovine model Yu, Xin-Yi Shi, Jian-Wei Rong, Yan-Sheng Chen, Yuan-Lu Liu, Tian-Wen Zang, Yi-Rui Fu, Ze-An Zhang, Jie-Min Han, Zhi-Fu Liu, Zhi-Gang Front Cardiovasc Med Cardiovascular Medicine OBJECTIVES: This study attempted to explore the hemodynamics and potential mechanisms driving pulmonary circulation in status of ventricular fibrillation (VF) following continuous-flow left ventricular assist device (CF-LVAD) implantation. METHODS: An ovine CF-LVAD model was built in small-tailed Han sheep, with the pump speed set as 2,400 rpm. VF was induced following ventricular tachycardia using a temporary pacemaker probe to stimulate the right and left ventricular free walls. The central venous pressure (CVP), pump flow (PF), pulmonary artery flow (PAF) and other major indicators were observed and recorded after VF. RESULTS: Low-flow systemic and pulmonary circulation could be sustained for 60 min under VF with sinus atrial rhythm after CF-LVAD implantation. The CVP gradually increased. The mean PF declined from 1.80 to 1.20 L/min, and the mean PAF decreased from 1.62 L/min to 0.87 L/min. Under VF with atrial fibrillation, the systemic and pulmonary circulation couldn’t be sustained. The CVP jumped from the 5 mmHg baseline to 12 mmHg, the mean PF rapidly decreased from 3.45 L/min to 0.79 L/min, and the PAF declined from 3.94 L/min to 0.77 L/min. CONCLUSION: The atrial rhythm and function might be essential for the circulation maintenance in patients with VF after CF-LVAD implantation. Frontiers Media S.A. 2023-01-09 /pmc/articles/PMC9868250/ /pubmed/36698959 http://dx.doi.org/10.3389/fcvm.2022.1000352 Text en Copyright © 2023 Yu, Shi, Rong, Chen, Liu, Zang, Fu, Zhang, Han and Liu. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Cardiovascular Medicine
Yu, Xin-Yi
Shi, Jian-Wei
Rong, Yan-Sheng
Chen, Yuan-Lu
Liu, Tian-Wen
Zang, Yi-Rui
Fu, Ze-An
Zhang, Jie-Min
Han, Zhi-Fu
Liu, Zhi-Gang
The role of atria in ventricular fibrillation after continuous-flow left ventricular assist device implantation in ovine model
title The role of atria in ventricular fibrillation after continuous-flow left ventricular assist device implantation in ovine model
title_full The role of atria in ventricular fibrillation after continuous-flow left ventricular assist device implantation in ovine model
title_fullStr The role of atria in ventricular fibrillation after continuous-flow left ventricular assist device implantation in ovine model
title_full_unstemmed The role of atria in ventricular fibrillation after continuous-flow left ventricular assist device implantation in ovine model
title_short The role of atria in ventricular fibrillation after continuous-flow left ventricular assist device implantation in ovine model
title_sort role of atria in ventricular fibrillation after continuous-flow left ventricular assist device implantation in ovine model
topic Cardiovascular Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9868250/
https://www.ncbi.nlm.nih.gov/pubmed/36698959
http://dx.doi.org/10.3389/fcvm.2022.1000352
work_keys_str_mv AT yuxinyi theroleofatriainventricularfibrillationaftercontinuousflowleftventricularassistdeviceimplantationinovinemodel
AT shijianwei theroleofatriainventricularfibrillationaftercontinuousflowleftventricularassistdeviceimplantationinovinemodel
AT rongyansheng theroleofatriainventricularfibrillationaftercontinuousflowleftventricularassistdeviceimplantationinovinemodel
AT chenyuanlu theroleofatriainventricularfibrillationaftercontinuousflowleftventricularassistdeviceimplantationinovinemodel
AT liutianwen theroleofatriainventricularfibrillationaftercontinuousflowleftventricularassistdeviceimplantationinovinemodel
AT zangyirui theroleofatriainventricularfibrillationaftercontinuousflowleftventricularassistdeviceimplantationinovinemodel
AT fuzean theroleofatriainventricularfibrillationaftercontinuousflowleftventricularassistdeviceimplantationinovinemodel
AT zhangjiemin theroleofatriainventricularfibrillationaftercontinuousflowleftventricularassistdeviceimplantationinovinemodel
AT hanzhifu theroleofatriainventricularfibrillationaftercontinuousflowleftventricularassistdeviceimplantationinovinemodel
AT liuzhigang theroleofatriainventricularfibrillationaftercontinuousflowleftventricularassistdeviceimplantationinovinemodel
AT yuxinyi roleofatriainventricularfibrillationaftercontinuousflowleftventricularassistdeviceimplantationinovinemodel
AT shijianwei roleofatriainventricularfibrillationaftercontinuousflowleftventricularassistdeviceimplantationinovinemodel
AT rongyansheng roleofatriainventricularfibrillationaftercontinuousflowleftventricularassistdeviceimplantationinovinemodel
AT chenyuanlu roleofatriainventricularfibrillationaftercontinuousflowleftventricularassistdeviceimplantationinovinemodel
AT liutianwen roleofatriainventricularfibrillationaftercontinuousflowleftventricularassistdeviceimplantationinovinemodel
AT zangyirui roleofatriainventricularfibrillationaftercontinuousflowleftventricularassistdeviceimplantationinovinemodel
AT fuzean roleofatriainventricularfibrillationaftercontinuousflowleftventricularassistdeviceimplantationinovinemodel
AT zhangjiemin roleofatriainventricularfibrillationaftercontinuousflowleftventricularassistdeviceimplantationinovinemodel
AT hanzhifu roleofatriainventricularfibrillationaftercontinuousflowleftventricularassistdeviceimplantationinovinemodel
AT liuzhigang roleofatriainventricularfibrillationaftercontinuousflowleftventricularassistdeviceimplantationinovinemodel