Cargando…

Trachea repair using an autologous pericardial patch combined with a 3D carbon fiber stent: A case report

This study is the first to use an autologous pericardial patch combined with a 3D carbon fiber stent for the plastic repair of a large trachea defect. Radical surgery is the optimal therapy for primary malignant tracheal tumors. Tracheoplasty or repair is required to guarantee trachea integrity and...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Bin, Zhang, Zhe, Guo, Yuanwei, Yu, Fenglei
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9869265/
https://www.ncbi.nlm.nih.gov/pubmed/36700013
http://dx.doi.org/10.3389/fsurg.2022.1086792
_version_ 1784876733406642176
author Wang, Bin
Zhang, Zhe
Guo, Yuanwei
Yu, Fenglei
author_facet Wang, Bin
Zhang, Zhe
Guo, Yuanwei
Yu, Fenglei
author_sort Wang, Bin
collection PubMed
description This study is the first to use an autologous pericardial patch combined with a 3D carbon fiber stent for the plastic repair of a large trachea defect. Radical surgery is the optimal therapy for primary malignant tracheal tumors. Tracheoplasty or repair is required to guarantee trachea integrity and normal ventilation function after tracheal tumor resection. Here, we present a case of plastic repair of the trachea using an autologous pericardial patch and a 3D custom-made carbon fiber stent. A 4 cm trachea defect was successfully repaired after resecting a malignant schwannoma. The postoperative ventilatory function was normal without obvious symptoms of discomfort. Fiberoptic bronchoscopy showed a smooth mucosal surface of the endotracheal wall and patency of the airway. CT scans performed 3 years after surgery showed no recurrence. Therefore, we can conclude that a 3D carbon fiber stent is feasible for abolishing patch floating and preventing tracheal stenosis.
format Online
Article
Text
id pubmed-9869265
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-98692652023-01-24 Trachea repair using an autologous pericardial patch combined with a 3D carbon fiber stent: A case report Wang, Bin Zhang, Zhe Guo, Yuanwei Yu, Fenglei Front Surg Surgery This study is the first to use an autologous pericardial patch combined with a 3D carbon fiber stent for the plastic repair of a large trachea defect. Radical surgery is the optimal therapy for primary malignant tracheal tumors. Tracheoplasty or repair is required to guarantee trachea integrity and normal ventilation function after tracheal tumor resection. Here, we present a case of plastic repair of the trachea using an autologous pericardial patch and a 3D custom-made carbon fiber stent. A 4 cm trachea defect was successfully repaired after resecting a malignant schwannoma. The postoperative ventilatory function was normal without obvious symptoms of discomfort. Fiberoptic bronchoscopy showed a smooth mucosal surface of the endotracheal wall and patency of the airway. CT scans performed 3 years after surgery showed no recurrence. Therefore, we can conclude that a 3D carbon fiber stent is feasible for abolishing patch floating and preventing tracheal stenosis. Frontiers Media S.A. 2023-01-09 /pmc/articles/PMC9869265/ /pubmed/36700013 http://dx.doi.org/10.3389/fsurg.2022.1086792 Text en © 2023 Wang, Zhang, Guo and Yu. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY) (https://creativecommons.org/licenses/by/4.0/) . The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Surgery
Wang, Bin
Zhang, Zhe
Guo, Yuanwei
Yu, Fenglei
Trachea repair using an autologous pericardial patch combined with a 3D carbon fiber stent: A case report
title Trachea repair using an autologous pericardial patch combined with a 3D carbon fiber stent: A case report
title_full Trachea repair using an autologous pericardial patch combined with a 3D carbon fiber stent: A case report
title_fullStr Trachea repair using an autologous pericardial patch combined with a 3D carbon fiber stent: A case report
title_full_unstemmed Trachea repair using an autologous pericardial patch combined with a 3D carbon fiber stent: A case report
title_short Trachea repair using an autologous pericardial patch combined with a 3D carbon fiber stent: A case report
title_sort trachea repair using an autologous pericardial patch combined with a 3d carbon fiber stent: a case report
topic Surgery
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9869265/
https://www.ncbi.nlm.nih.gov/pubmed/36700013
http://dx.doi.org/10.3389/fsurg.2022.1086792
work_keys_str_mv AT wangbin trachearepairusinganautologouspericardialpatchcombinedwitha3dcarbonfiberstentacasereport
AT zhangzhe trachearepairusinganautologouspericardialpatchcombinedwitha3dcarbonfiberstentacasereport
AT guoyuanwei trachearepairusinganautologouspericardialpatchcombinedwitha3dcarbonfiberstentacasereport
AT yufenglei trachearepairusinganautologouspericardialpatchcombinedwitha3dcarbonfiberstentacasereport