Cargando…
The application of three-dimensional printed patient-specific drilling templates for expansive open-door laminoplasty: A single-center, prospective randomized controlled study
BACKGROUND: The choice of trough position in Expansive open-door laminoplasty (EOLP) mostly relied on bony landmarks and surgeons’ experience. The present study was to validate the efficacy of the three-dimensional (3D) printed patient-specific drilling templates with the function of locating and de...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9869670/ https://www.ncbi.nlm.nih.gov/pubmed/36700026 http://dx.doi.org/10.3389/fsurg.2022.1084804 |
_version_ | 1784876815990390784 |
---|---|
author | Huang, Kangkang Pan, Xuelin Wen, Yuting Wang, Beiyu Ding, Chen Wu, Tingkui Rong, Xin Liu, Hao |
author_facet | Huang, Kangkang Pan, Xuelin Wen, Yuting Wang, Beiyu Ding, Chen Wu, Tingkui Rong, Xin Liu, Hao |
author_sort | Huang, Kangkang |
collection | PubMed |
description | BACKGROUND: The choice of trough position in Expansive open-door laminoplasty (EOLP) mostly relied on bony landmarks and surgeons’ experience. The present study was to validate the efficacy of the three-dimensional (3D) printed patient-specific drilling templates with the function of locating and depth control for EOLP. MATERIALS AND METHODS: A single-center, prospective randomized controlled study was conducted on the patients who underwent unilateral EOLP from August 2019 to December 2020. The 3D printed patient-specific drilling template was fabricated and used in the template group. All the EOLP were performed by a senior surgeon and a junior surgeon. The clinical outcomes and radiographic results were evaluated. RESULTS: A total of 37 patients who completed the 12-month follow-up were analyzed. The clinical outcomes were significantly improved after surgery in both groups (P < 0.05). The visual analogue scale (VAS) scores were significantly lower in the template group at 12 months postoperatively (P < 0.05). The anteroposterior diameter, Pavlov's ratio and Open angle were all higher in the template group than those in the control group at 3 days and 12 months postoperatively (P < 0.05). The satisfaction of the trough position on both sides and incomplete fracture rate on the hinge side were higher in the template group based on the CT scans taken 3 days after surgery (P < 0.05). To the junior surgeon, the satisfaction and the incomplete fracture rate were significantly higher in the template group compared with those in the control group (P < 0.05). CONCLUSION: The application of 3D printed patient-specific drilling templates with the function of locating and depth control for EOLP could improve the outcome of neck pain relief and expand the decompression. It can also improve the satisfaction of the trough position on the open-door side and the hinge side and decrease the complete fracture rate on the hinge side, especially for the junior surgeon. |
format | Online Article Text |
id | pubmed-9869670 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-98696702023-01-24 The application of three-dimensional printed patient-specific drilling templates for expansive open-door laminoplasty: A single-center, prospective randomized controlled study Huang, Kangkang Pan, Xuelin Wen, Yuting Wang, Beiyu Ding, Chen Wu, Tingkui Rong, Xin Liu, Hao Front Surg Surgery BACKGROUND: The choice of trough position in Expansive open-door laminoplasty (EOLP) mostly relied on bony landmarks and surgeons’ experience. The present study was to validate the efficacy of the three-dimensional (3D) printed patient-specific drilling templates with the function of locating and depth control for EOLP. MATERIALS AND METHODS: A single-center, prospective randomized controlled study was conducted on the patients who underwent unilateral EOLP from August 2019 to December 2020. The 3D printed patient-specific drilling template was fabricated and used in the template group. All the EOLP were performed by a senior surgeon and a junior surgeon. The clinical outcomes and radiographic results were evaluated. RESULTS: A total of 37 patients who completed the 12-month follow-up were analyzed. The clinical outcomes were significantly improved after surgery in both groups (P < 0.05). The visual analogue scale (VAS) scores were significantly lower in the template group at 12 months postoperatively (P < 0.05). The anteroposterior diameter, Pavlov's ratio and Open angle were all higher in the template group than those in the control group at 3 days and 12 months postoperatively (P < 0.05). The satisfaction of the trough position on both sides and incomplete fracture rate on the hinge side were higher in the template group based on the CT scans taken 3 days after surgery (P < 0.05). To the junior surgeon, the satisfaction and the incomplete fracture rate were significantly higher in the template group compared with those in the control group (P < 0.05). CONCLUSION: The application of 3D printed patient-specific drilling templates with the function of locating and depth control for EOLP could improve the outcome of neck pain relief and expand the decompression. It can also improve the satisfaction of the trough position on the open-door side and the hinge side and decrease the complete fracture rate on the hinge side, especially for the junior surgeon. Frontiers Media S.A. 2023-01-09 /pmc/articles/PMC9869670/ /pubmed/36700026 http://dx.doi.org/10.3389/fsurg.2022.1084804 Text en © 2023 Huang, Pan, Wen, Wang, Ding, Wu, Rong and Liu. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY) (https://creativecommons.org/licenses/by/4.0/) . The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Surgery Huang, Kangkang Pan, Xuelin Wen, Yuting Wang, Beiyu Ding, Chen Wu, Tingkui Rong, Xin Liu, Hao The application of three-dimensional printed patient-specific drilling templates for expansive open-door laminoplasty: A single-center, prospective randomized controlled study |
title | The application of three-dimensional printed patient-specific drilling templates for expansive open-door laminoplasty: A single-center, prospective randomized controlled study |
title_full | The application of three-dimensional printed patient-specific drilling templates for expansive open-door laminoplasty: A single-center, prospective randomized controlled study |
title_fullStr | The application of three-dimensional printed patient-specific drilling templates for expansive open-door laminoplasty: A single-center, prospective randomized controlled study |
title_full_unstemmed | The application of three-dimensional printed patient-specific drilling templates for expansive open-door laminoplasty: A single-center, prospective randomized controlled study |
title_short | The application of three-dimensional printed patient-specific drilling templates for expansive open-door laminoplasty: A single-center, prospective randomized controlled study |
title_sort | application of three-dimensional printed patient-specific drilling templates for expansive open-door laminoplasty: a single-center, prospective randomized controlled study |
topic | Surgery |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9869670/ https://www.ncbi.nlm.nih.gov/pubmed/36700026 http://dx.doi.org/10.3389/fsurg.2022.1084804 |
work_keys_str_mv | AT huangkangkang theapplicationofthreedimensionalprintedpatientspecificdrillingtemplatesforexpansiveopendoorlaminoplastyasinglecenterprospectiverandomizedcontrolledstudy AT panxuelin theapplicationofthreedimensionalprintedpatientspecificdrillingtemplatesforexpansiveopendoorlaminoplastyasinglecenterprospectiverandomizedcontrolledstudy AT wenyuting theapplicationofthreedimensionalprintedpatientspecificdrillingtemplatesforexpansiveopendoorlaminoplastyasinglecenterprospectiverandomizedcontrolledstudy AT wangbeiyu theapplicationofthreedimensionalprintedpatientspecificdrillingtemplatesforexpansiveopendoorlaminoplastyasinglecenterprospectiverandomizedcontrolledstudy AT dingchen theapplicationofthreedimensionalprintedpatientspecificdrillingtemplatesforexpansiveopendoorlaminoplastyasinglecenterprospectiverandomizedcontrolledstudy AT wutingkui theapplicationofthreedimensionalprintedpatientspecificdrillingtemplatesforexpansiveopendoorlaminoplastyasinglecenterprospectiverandomizedcontrolledstudy AT rongxin theapplicationofthreedimensionalprintedpatientspecificdrillingtemplatesforexpansiveopendoorlaminoplastyasinglecenterprospectiverandomizedcontrolledstudy AT liuhao theapplicationofthreedimensionalprintedpatientspecificdrillingtemplatesforexpansiveopendoorlaminoplastyasinglecenterprospectiverandomizedcontrolledstudy AT huangkangkang applicationofthreedimensionalprintedpatientspecificdrillingtemplatesforexpansiveopendoorlaminoplastyasinglecenterprospectiverandomizedcontrolledstudy AT panxuelin applicationofthreedimensionalprintedpatientspecificdrillingtemplatesforexpansiveopendoorlaminoplastyasinglecenterprospectiverandomizedcontrolledstudy AT wenyuting applicationofthreedimensionalprintedpatientspecificdrillingtemplatesforexpansiveopendoorlaminoplastyasinglecenterprospectiverandomizedcontrolledstudy AT wangbeiyu applicationofthreedimensionalprintedpatientspecificdrillingtemplatesforexpansiveopendoorlaminoplastyasinglecenterprospectiverandomizedcontrolledstudy AT dingchen applicationofthreedimensionalprintedpatientspecificdrillingtemplatesforexpansiveopendoorlaminoplastyasinglecenterprospectiverandomizedcontrolledstudy AT wutingkui applicationofthreedimensionalprintedpatientspecificdrillingtemplatesforexpansiveopendoorlaminoplastyasinglecenterprospectiverandomizedcontrolledstudy AT rongxin applicationofthreedimensionalprintedpatientspecificdrillingtemplatesforexpansiveopendoorlaminoplastyasinglecenterprospectiverandomizedcontrolledstudy AT liuhao applicationofthreedimensionalprintedpatientspecificdrillingtemplatesforexpansiveopendoorlaminoplastyasinglecenterprospectiverandomizedcontrolledstudy |