Cargando…
New insight: particle flow rate from the airways as an indicator of cardiac failure in the intensive care unit
AIMS: Exhaled breath particles have been explored for diagnosing different lung diseases. We recently showed in an experimental model that different cardiac output results in different particle flow rate (PFR) from the airways. Given the well‐known close relationship between impaired cardiac functio...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9871686/ https://www.ncbi.nlm.nih.gov/pubmed/36442863 http://dx.doi.org/10.1002/ehf2.14242 |
_version_ | 1784877233736777728 |
---|---|
author | Lindstedt, Sandra Hyllen, Snejana |
author_facet | Lindstedt, Sandra Hyllen, Snejana |
author_sort | Lindstedt, Sandra |
collection | PubMed |
description | AIMS: Exhaled breath particles have been explored for diagnosing different lung diseases. We recently showed in an experimental model that different cardiac output results in different particle flow rate (PFR) from the airways. Given the well‐known close relationship between impaired cardiac function and respiratory failure, we hypothesized that PFR in exhaled air can be used to detect cardiac failure. METHODS: PFR was analysed using a customized PExA device. Particles in the range of 0.41–4.55 μm were measured. The included patients (n = 20) underwent cardiac surgery and received mechanical ventilation as a part of routine post‐operative care. Ten patients with clinical signs of pronounced post‐operative haemodynamic instability and need for inotrope or mechanical support had been selected to the cardiac failure group. The control group consisted of 10 patients without signs of cardiac failure. RESULTS: The patients in cardiac failure group required inotropic support in the form of dobutamine (9/10), epinephrine (2/10), or levosimendan (4/10) or use of an intra‐aortic balloon pump (4/10). There was no use of inotropes or mechanical support devices among the controls. All patients in the cardiac failure group had pre‐operative left ventricular ejection fraction ≤40% compared with the control group, whose pre‐operative ejection fraction was ≥50%, P < 0.001. Patients with cardiac failure had significantly longer median total time in mechanical ventilation compared with the patients in the control group: 53.5 h (IQR 6.8–116101.0 h) and 4.5 h (IQR 4.0–5.5 h), respectively, P < 0.001, and the median length of stay in the ICU, 165 h (IQR 28–192 h) and 22 h (IQR 20–23.5 h), respectively, P = 0.007. Median PFR in patients with cardiac failure was higher than PFR in those with normal cardiac function: 80.9 particles/min (interquartile range (IQR) 25.8–336.6 particles/min), vs. 15.3 particles/min (IQR 8.1–17.7 particles/min), respectively, P < 0.001. Median particle mass was 8.95 ng (IQR 1.68–41.73 ng) in the cardiac failure group and 0.75 ng (IQR 0.18–1.45 ng) in the control group, P = 0.002. CONCLUSIONS: Patients with post‐operative cardiac failure following cardiac surgery exhibited an increase in exhaled particle mass and PFR compared with the control group, indicating a significant difference between those two groups. The increase in particle mass and PFR in the absence of respiratory pathologies may indicate cardiac failure. In comparison with controls, impaired cardiac function was also associated with different composition of the particles regarding their size distribution. |
format | Online Article Text |
id | pubmed-9871686 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-98716862023-01-25 New insight: particle flow rate from the airways as an indicator of cardiac failure in the intensive care unit Lindstedt, Sandra Hyllen, Snejana ESC Heart Fail Original Articles AIMS: Exhaled breath particles have been explored for diagnosing different lung diseases. We recently showed in an experimental model that different cardiac output results in different particle flow rate (PFR) from the airways. Given the well‐known close relationship between impaired cardiac function and respiratory failure, we hypothesized that PFR in exhaled air can be used to detect cardiac failure. METHODS: PFR was analysed using a customized PExA device. Particles in the range of 0.41–4.55 μm were measured. The included patients (n = 20) underwent cardiac surgery and received mechanical ventilation as a part of routine post‐operative care. Ten patients with clinical signs of pronounced post‐operative haemodynamic instability and need for inotrope or mechanical support had been selected to the cardiac failure group. The control group consisted of 10 patients without signs of cardiac failure. RESULTS: The patients in cardiac failure group required inotropic support in the form of dobutamine (9/10), epinephrine (2/10), or levosimendan (4/10) or use of an intra‐aortic balloon pump (4/10). There was no use of inotropes or mechanical support devices among the controls. All patients in the cardiac failure group had pre‐operative left ventricular ejection fraction ≤40% compared with the control group, whose pre‐operative ejection fraction was ≥50%, P < 0.001. Patients with cardiac failure had significantly longer median total time in mechanical ventilation compared with the patients in the control group: 53.5 h (IQR 6.8–116101.0 h) and 4.5 h (IQR 4.0–5.5 h), respectively, P < 0.001, and the median length of stay in the ICU, 165 h (IQR 28–192 h) and 22 h (IQR 20–23.5 h), respectively, P = 0.007. Median PFR in patients with cardiac failure was higher than PFR in those with normal cardiac function: 80.9 particles/min (interquartile range (IQR) 25.8–336.6 particles/min), vs. 15.3 particles/min (IQR 8.1–17.7 particles/min), respectively, P < 0.001. Median particle mass was 8.95 ng (IQR 1.68–41.73 ng) in the cardiac failure group and 0.75 ng (IQR 0.18–1.45 ng) in the control group, P = 0.002. CONCLUSIONS: Patients with post‐operative cardiac failure following cardiac surgery exhibited an increase in exhaled particle mass and PFR compared with the control group, indicating a significant difference between those two groups. The increase in particle mass and PFR in the absence of respiratory pathologies may indicate cardiac failure. In comparison with controls, impaired cardiac function was also associated with different composition of the particles regarding their size distribution. John Wiley and Sons Inc. 2022-11-28 /pmc/articles/PMC9871686/ /pubmed/36442863 http://dx.doi.org/10.1002/ehf2.14242 Text en © 2022 The Authors. ESC Heart Failure published by John Wiley & Sons Ltd on behalf of European Society of Cardiology. https://creativecommons.org/licenses/by-nc/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes. |
spellingShingle | Original Articles Lindstedt, Sandra Hyllen, Snejana New insight: particle flow rate from the airways as an indicator of cardiac failure in the intensive care unit |
title | New insight: particle flow rate from the airways as an indicator of cardiac failure in the intensive care unit |
title_full | New insight: particle flow rate from the airways as an indicator of cardiac failure in the intensive care unit |
title_fullStr | New insight: particle flow rate from the airways as an indicator of cardiac failure in the intensive care unit |
title_full_unstemmed | New insight: particle flow rate from the airways as an indicator of cardiac failure in the intensive care unit |
title_short | New insight: particle flow rate from the airways as an indicator of cardiac failure in the intensive care unit |
title_sort | new insight: particle flow rate from the airways as an indicator of cardiac failure in the intensive care unit |
topic | Original Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9871686/ https://www.ncbi.nlm.nih.gov/pubmed/36442863 http://dx.doi.org/10.1002/ehf2.14242 |
work_keys_str_mv | AT lindstedtsandra newinsightparticleflowratefromtheairwaysasanindicatorofcardiacfailureintheintensivecareunit AT hyllensnejana newinsightparticleflowratefromtheairwaysasanindicatorofcardiacfailureintheintensivecareunit |