Cargando…
Functional results and unfavorable events after treatment of proximal humerus fractures using a new locking plate system
BACKGROUND: Proximal humerus fractures are often treated with a fixed-angle titanium plate osteosynthesis. Recently, plates made of alternative materials such as carbon fibre-reinforced polyetheretherketone (CFR-PEEK) have been introduced. This study presents the postoperative results of patients tr...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9872058/ https://www.ncbi.nlm.nih.gov/pubmed/36694169 http://dx.doi.org/10.1186/s12891-023-06176-5 |
_version_ | 1784877320951037952 |
---|---|
author | Kimmeyer, Michael Schmalzl, Jonas Rentschler, Verena Jessen, Malik Gerhardt, Christian Lehmann, Lars-Johannes |
author_facet | Kimmeyer, Michael Schmalzl, Jonas Rentschler, Verena Jessen, Malik Gerhardt, Christian Lehmann, Lars-Johannes |
author_sort | Kimmeyer, Michael |
collection | PubMed |
description | BACKGROUND: Proximal humerus fractures are often treated with a fixed-angle titanium plate osteosynthesis. Recently, plates made of alternative materials such as carbon fibre-reinforced polyetheretherketone (CFR-PEEK) have been introduced. This study presents the postoperative results of patients treated with a CFR-PEEK plate. METHODS: Patients with proximal humerus fractures treated with a CFR-PEEK plate (PEEKPower™ Humeral Fracture Plate (HFP)) were included. In follow-up examination, age and gender adjusted Constant-Murley Score (ACS), Subjective Shoulder Value (SSV), Quick Disabilities of the Arm, Shoulder and Hand Score (QDASH) and pain score (Visual Analog Scale (VAS)) were analyzed. General condition at follow-up was measured by European Quality of Life 5 Dimensions 3 Level Version (EQ-5D-3L). Range of motion was recorded. In addition, radiographs at follow-up, unfavorable events and revision rate were analyzed. RESULTS: In total, 98 patients (66.0 ± 13.2 years, 74 females, 24 males) were reexamined. Mean follow-up was 27.6 ± 13.2 months. There were 15 2-part, 28 3-part and 55 4-part fractures. The functional scores showed good results: SSV 83.3 ± 15.6%, QDASH 13.1 ± 17.0 and ACS 80.4 ± 16.0. A 4-part-fracture, head split component, nonanatomic head shaft reposition and preoperative radiological signs of osteoarthritis were significant negative predictors for poorer clinical scores. Unfavourable events were observed in 27 patients (27.6%). Revision surgery was performed in 8 (8.2%) patients. Risk factors for an unfavourable event were female gender, age of 50 years and older, diabetes, affected dominant hand, 4-part fracture, head split and preoperative radiological signs of osteoarthritis. CONCLUSION: There are several advantages of the CFR-PEEK plate (PEEKPower™ Humeral Fracture Plate (HFP)) such as the polyaxial screw placement and higher stability of locking screws. In summary, the CFR-PEEK plate osteosynthesis is a good alternative with comparable clinical results and some biomechanical advantages. Proximal humerus fractures show good clinical results after treatment with a CFR-PEEK plate. The revision rate and the risk of unfavorable events are not increased compared to conventional titanium plate osteosynthesis. LEVEL OF EVIDENCE: IV |
format | Online Article Text |
id | pubmed-9872058 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-98720582023-01-25 Functional results and unfavorable events after treatment of proximal humerus fractures using a new locking plate system Kimmeyer, Michael Schmalzl, Jonas Rentschler, Verena Jessen, Malik Gerhardt, Christian Lehmann, Lars-Johannes BMC Musculoskelet Disord Research BACKGROUND: Proximal humerus fractures are often treated with a fixed-angle titanium plate osteosynthesis. Recently, plates made of alternative materials such as carbon fibre-reinforced polyetheretherketone (CFR-PEEK) have been introduced. This study presents the postoperative results of patients treated with a CFR-PEEK plate. METHODS: Patients with proximal humerus fractures treated with a CFR-PEEK plate (PEEKPower™ Humeral Fracture Plate (HFP)) were included. In follow-up examination, age and gender adjusted Constant-Murley Score (ACS), Subjective Shoulder Value (SSV), Quick Disabilities of the Arm, Shoulder and Hand Score (QDASH) and pain score (Visual Analog Scale (VAS)) were analyzed. General condition at follow-up was measured by European Quality of Life 5 Dimensions 3 Level Version (EQ-5D-3L). Range of motion was recorded. In addition, radiographs at follow-up, unfavorable events and revision rate were analyzed. RESULTS: In total, 98 patients (66.0 ± 13.2 years, 74 females, 24 males) were reexamined. Mean follow-up was 27.6 ± 13.2 months. There were 15 2-part, 28 3-part and 55 4-part fractures. The functional scores showed good results: SSV 83.3 ± 15.6%, QDASH 13.1 ± 17.0 and ACS 80.4 ± 16.0. A 4-part-fracture, head split component, nonanatomic head shaft reposition and preoperative radiological signs of osteoarthritis were significant negative predictors for poorer clinical scores. Unfavourable events were observed in 27 patients (27.6%). Revision surgery was performed in 8 (8.2%) patients. Risk factors for an unfavourable event were female gender, age of 50 years and older, diabetes, affected dominant hand, 4-part fracture, head split and preoperative radiological signs of osteoarthritis. CONCLUSION: There are several advantages of the CFR-PEEK plate (PEEKPower™ Humeral Fracture Plate (HFP)) such as the polyaxial screw placement and higher stability of locking screws. In summary, the CFR-PEEK plate osteosynthesis is a good alternative with comparable clinical results and some biomechanical advantages. Proximal humerus fractures show good clinical results after treatment with a CFR-PEEK plate. The revision rate and the risk of unfavorable events are not increased compared to conventional titanium plate osteosynthesis. LEVEL OF EVIDENCE: IV BioMed Central 2023-01-24 /pmc/articles/PMC9872058/ /pubmed/36694169 http://dx.doi.org/10.1186/s12891-023-06176-5 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Kimmeyer, Michael Schmalzl, Jonas Rentschler, Verena Jessen, Malik Gerhardt, Christian Lehmann, Lars-Johannes Functional results and unfavorable events after treatment of proximal humerus fractures using a new locking plate system |
title | Functional results and unfavorable events after treatment of proximal humerus fractures using a new locking plate system |
title_full | Functional results and unfavorable events after treatment of proximal humerus fractures using a new locking plate system |
title_fullStr | Functional results and unfavorable events after treatment of proximal humerus fractures using a new locking plate system |
title_full_unstemmed | Functional results and unfavorable events after treatment of proximal humerus fractures using a new locking plate system |
title_short | Functional results and unfavorable events after treatment of proximal humerus fractures using a new locking plate system |
title_sort | functional results and unfavorable events after treatment of proximal humerus fractures using a new locking plate system |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9872058/ https://www.ncbi.nlm.nih.gov/pubmed/36694169 http://dx.doi.org/10.1186/s12891-023-06176-5 |
work_keys_str_mv | AT kimmeyermichael functionalresultsandunfavorableeventsaftertreatmentofproximalhumerusfracturesusinganewlockingplatesystem AT schmalzljonas functionalresultsandunfavorableeventsaftertreatmentofproximalhumerusfracturesusinganewlockingplatesystem AT rentschlerverena functionalresultsandunfavorableeventsaftertreatmentofproximalhumerusfracturesusinganewlockingplatesystem AT jessenmalik functionalresultsandunfavorableeventsaftertreatmentofproximalhumerusfracturesusinganewlockingplatesystem AT gerhardtchristian functionalresultsandunfavorableeventsaftertreatmentofproximalhumerusfracturesusinganewlockingplatesystem AT lehmannlarsjohannes functionalresultsandunfavorableeventsaftertreatmentofproximalhumerusfracturesusinganewlockingplatesystem |