A Custom Device to Couple Proximal and Distal Femoral Stems: A Case Report and Literature Review
Complex periprosthetic fractures may occur with existing ipsilateral hip and knee implants. These cases are challenging with few options. We report on a custom coupler used to connect a hinged distal femoral replacement to an existing revision hip stem. This option was preferred to a total replaceme...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9873500/ https://www.ncbi.nlm.nih.gov/pubmed/36713938 http://dx.doi.org/10.1016/j.artd.2022.101089 |
_version_ | 1784877609794928640 |
---|---|
author | Corces, Arturo Heifner, John Zavurov, Gabriel |
author_facet | Corces, Arturo Heifner, John Zavurov, Gabriel |
author_sort | Corces, Arturo |
collection | PubMed |
description | Complex periprosthetic fractures may occur with existing ipsilateral hip and knee implants. These cases are challenging with few options. We report on a custom coupler used to connect a hinged distal femoral replacement to an existing revision hip stem. This option was preferred to a total replacement of the femur. The custom coupler maintained the anatomic attachments of the proximal femur, preserved abductor strength during ambulation, and mitigated the morbidity which may arise from a total femur replacement. At 15 months postoperatively, the patient reported no pain, did not demonstrate an antalgic gait pattern, and had satisfactory range of motion at the hip and knee. The literature displays clinical and biomechanical efficacy for coupling devices although complications and device failure are quite variable. |
format | Online Article Text |
id | pubmed-9873500 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-98735002023-01-26 A Custom Device to Couple Proximal and Distal Femoral Stems: A Case Report and Literature Review Corces, Arturo Heifner, John Zavurov, Gabriel Arthroplast Today Case Report Complex periprosthetic fractures may occur with existing ipsilateral hip and knee implants. These cases are challenging with few options. We report on a custom coupler used to connect a hinged distal femoral replacement to an existing revision hip stem. This option was preferred to a total replacement of the femur. The custom coupler maintained the anatomic attachments of the proximal femur, preserved abductor strength during ambulation, and mitigated the morbidity which may arise from a total femur replacement. At 15 months postoperatively, the patient reported no pain, did not demonstrate an antalgic gait pattern, and had satisfactory range of motion at the hip and knee. The literature displays clinical and biomechanical efficacy for coupling devices although complications and device failure are quite variable. Elsevier 2023-01-18 /pmc/articles/PMC9873500/ /pubmed/36713938 http://dx.doi.org/10.1016/j.artd.2022.101089 Text en © 2022 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Case Report Corces, Arturo Heifner, John Zavurov, Gabriel A Custom Device to Couple Proximal and Distal Femoral Stems: A Case Report and Literature Review |
title | A Custom Device to Couple Proximal and Distal Femoral Stems: A Case Report and Literature Review |
title_full | A Custom Device to Couple Proximal and Distal Femoral Stems: A Case Report and Literature Review |
title_fullStr | A Custom Device to Couple Proximal and Distal Femoral Stems: A Case Report and Literature Review |
title_full_unstemmed | A Custom Device to Couple Proximal and Distal Femoral Stems: A Case Report and Literature Review |
title_short | A Custom Device to Couple Proximal and Distal Femoral Stems: A Case Report and Literature Review |
title_sort | custom device to couple proximal and distal femoral stems: a case report and literature review |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9873500/ https://www.ncbi.nlm.nih.gov/pubmed/36713938 http://dx.doi.org/10.1016/j.artd.2022.101089 |
work_keys_str_mv | AT corcesarturo acustomdevicetocoupleproximalanddistalfemoralstemsacasereportandliteraturereview AT heifnerjohn acustomdevicetocoupleproximalanddistalfemoralstemsacasereportandliteraturereview AT zavurovgabriel acustomdevicetocoupleproximalanddistalfemoralstemsacasereportandliteraturereview AT corcesarturo customdevicetocoupleproximalanddistalfemoralstemsacasereportandliteraturereview AT heifnerjohn customdevicetocoupleproximalanddistalfemoralstemsacasereportandliteraturereview AT zavurovgabriel customdevicetocoupleproximalanddistalfemoralstemsacasereportandliteraturereview |