A Custom Device to Couple Proximal and Distal Femoral Stems: A Case Report and Literature Review

Complex periprosthetic fractures may occur with existing ipsilateral hip and knee implants. These cases are challenging with few options. We report on a custom coupler used to connect a hinged distal femoral replacement to an existing revision hip stem. This option was preferred to a total replaceme...

Descripción completa

Detalles Bibliográficos
Autores principales: Corces, Arturo, Heifner, John, Zavurov, Gabriel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9873500/
https://www.ncbi.nlm.nih.gov/pubmed/36713938
http://dx.doi.org/10.1016/j.artd.2022.101089
_version_ 1784877609794928640
author Corces, Arturo
Heifner, John
Zavurov, Gabriel
author_facet Corces, Arturo
Heifner, John
Zavurov, Gabriel
author_sort Corces, Arturo
collection PubMed
description Complex periprosthetic fractures may occur with existing ipsilateral hip and knee implants. These cases are challenging with few options. We report on a custom coupler used to connect a hinged distal femoral replacement to an existing revision hip stem. This option was preferred to a total replacement of the femur. The custom coupler maintained the anatomic attachments of the proximal femur, preserved abductor strength during ambulation, and mitigated the morbidity which may arise from a total femur replacement. At 15 months postoperatively, the patient reported no pain, did not demonstrate an antalgic gait pattern, and had satisfactory range of motion at the hip and knee. The literature displays clinical and biomechanical efficacy for coupling devices although complications and device failure are quite variable.
format Online
Article
Text
id pubmed-9873500
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-98735002023-01-26 A Custom Device to Couple Proximal and Distal Femoral Stems: A Case Report and Literature Review Corces, Arturo Heifner, John Zavurov, Gabriel Arthroplast Today Case Report Complex periprosthetic fractures may occur with existing ipsilateral hip and knee implants. These cases are challenging with few options. We report on a custom coupler used to connect a hinged distal femoral replacement to an existing revision hip stem. This option was preferred to a total replacement of the femur. The custom coupler maintained the anatomic attachments of the proximal femur, preserved abductor strength during ambulation, and mitigated the morbidity which may arise from a total femur replacement. At 15 months postoperatively, the patient reported no pain, did not demonstrate an antalgic gait pattern, and had satisfactory range of motion at the hip and knee. The literature displays clinical and biomechanical efficacy for coupling devices although complications and device failure are quite variable. Elsevier 2023-01-18 /pmc/articles/PMC9873500/ /pubmed/36713938 http://dx.doi.org/10.1016/j.artd.2022.101089 Text en © 2022 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case Report
Corces, Arturo
Heifner, John
Zavurov, Gabriel
A Custom Device to Couple Proximal and Distal Femoral Stems: A Case Report and Literature Review
title A Custom Device to Couple Proximal and Distal Femoral Stems: A Case Report and Literature Review
title_full A Custom Device to Couple Proximal and Distal Femoral Stems: A Case Report and Literature Review
title_fullStr A Custom Device to Couple Proximal and Distal Femoral Stems: A Case Report and Literature Review
title_full_unstemmed A Custom Device to Couple Proximal and Distal Femoral Stems: A Case Report and Literature Review
title_short A Custom Device to Couple Proximal and Distal Femoral Stems: A Case Report and Literature Review
title_sort custom device to couple proximal and distal femoral stems: a case report and literature review
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9873500/
https://www.ncbi.nlm.nih.gov/pubmed/36713938
http://dx.doi.org/10.1016/j.artd.2022.101089
work_keys_str_mv AT corcesarturo acustomdevicetocoupleproximalanddistalfemoralstemsacasereportandliteraturereview
AT heifnerjohn acustomdevicetocoupleproximalanddistalfemoralstemsacasereportandliteraturereview
AT zavurovgabriel acustomdevicetocoupleproximalanddistalfemoralstemsacasereportandliteraturereview
AT corcesarturo customdevicetocoupleproximalanddistalfemoralstemsacasereportandliteraturereview
AT heifnerjohn customdevicetocoupleproximalanddistalfemoralstemsacasereportandliteraturereview
AT zavurovgabriel customdevicetocoupleproximalanddistalfemoralstemsacasereportandliteraturereview