Case report: Individualized pulsed electromagnetic field therapy in a Long COVID patient using the Adaptive Force as biomarker

The increasing prevalence of Long COVID is an imminent public health disaster, and established approaches have not provided adequate diagnostics or treatments. Recently, anesthetic blockade of the stellate ganglion was reported to improve Long COVID symptoms in a small case series, purportedly by “r...

Descripción completa

Detalles Bibliográficos
Autores principales: Schaefer, Laura V., Bittmann, Frank N.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9874300/
https://www.ncbi.nlm.nih.gov/pubmed/36714125
http://dx.doi.org/10.3389/fmed.2022.879971
_version_ 1784877779236421632
author Schaefer, Laura V.
Bittmann, Frank N.
author_facet Schaefer, Laura V.
Bittmann, Frank N.
author_sort Schaefer, Laura V.
collection PubMed
description The increasing prevalence of Long COVID is an imminent public health disaster, and established approaches have not provided adequate diagnostics or treatments. Recently, anesthetic blockade of the stellate ganglion was reported to improve Long COVID symptoms in a small case series, purportedly by “rebooting” the autonomic nervous system. Here, we present a novel diagnostic approach based on the Adaptive Force (AF), and report sustained positive outcome for one severely affected Long COVID patient using individualized pulsed electromagnetic field (PEMF) at the area C7/T1. AF reflects the capacity of the neuromuscular system to adapt adequately to external forces in an isometric holding manner. In case, maximal isometric AF (AFiso(max)) is exceeded, the muscle merges into eccentric muscle action. Thereby, the force usually increases further until maximal AF (AFmax) is reached. In case adaptation is optimal, AFiso(max) is ~99–100% of AFmax. This holding capacity (AFiso(max)) was found to be vulnerable to disruption by unpleasant stimulus and, hence, was regarded as functional parameter. AF was assessed by an objectified manual muscle test using a handheld device. Prior to treatment, AFiso(max) was considerably lower than AFmax for hip flexors (62 N = ~28% AFmax) and elbow flexors (71 N = ~44% AFmax); i.e., maximal holding capacity was significantly reduced, indicating dysfunctional motor control. We tested PEMF at C7/T1, identified a frequency that improved neuromuscular function, and applied it for ~15 min. Immediately post-treatment, AFiso(max) increased to ~210 N (~100% AFmax) at hip and 184 N (~100% AFmax) at elbow. Subjective Long COVID symptoms resolved the following day. At 4 weeks post-treatment, maximal holding capacity was still on a similarly high level as for immediately post-treatment (~100% AFmax) and patient was symptom-free. At 6 months the patient's Long COVID symptoms have not returned. This case report suggests (1) AF could be a promising diagnostic for post-infectious illness, (2) AF can be used to test effective treatments for post-infectious illness, and (3) individualized PEMF may resolve post-infectious symptoms.
format Online
Article
Text
id pubmed-9874300
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-98743002023-01-26 Case report: Individualized pulsed electromagnetic field therapy in a Long COVID patient using the Adaptive Force as biomarker Schaefer, Laura V. Bittmann, Frank N. Front Med (Lausanne) Medicine The increasing prevalence of Long COVID is an imminent public health disaster, and established approaches have not provided adequate diagnostics or treatments. Recently, anesthetic blockade of the stellate ganglion was reported to improve Long COVID symptoms in a small case series, purportedly by “rebooting” the autonomic nervous system. Here, we present a novel diagnostic approach based on the Adaptive Force (AF), and report sustained positive outcome for one severely affected Long COVID patient using individualized pulsed electromagnetic field (PEMF) at the area C7/T1. AF reflects the capacity of the neuromuscular system to adapt adequately to external forces in an isometric holding manner. In case, maximal isometric AF (AFiso(max)) is exceeded, the muscle merges into eccentric muscle action. Thereby, the force usually increases further until maximal AF (AFmax) is reached. In case adaptation is optimal, AFiso(max) is ~99–100% of AFmax. This holding capacity (AFiso(max)) was found to be vulnerable to disruption by unpleasant stimulus and, hence, was regarded as functional parameter. AF was assessed by an objectified manual muscle test using a handheld device. Prior to treatment, AFiso(max) was considerably lower than AFmax for hip flexors (62 N = ~28% AFmax) and elbow flexors (71 N = ~44% AFmax); i.e., maximal holding capacity was significantly reduced, indicating dysfunctional motor control. We tested PEMF at C7/T1, identified a frequency that improved neuromuscular function, and applied it for ~15 min. Immediately post-treatment, AFiso(max) increased to ~210 N (~100% AFmax) at hip and 184 N (~100% AFmax) at elbow. Subjective Long COVID symptoms resolved the following day. At 4 weeks post-treatment, maximal holding capacity was still on a similarly high level as for immediately post-treatment (~100% AFmax) and patient was symptom-free. At 6 months the patient's Long COVID symptoms have not returned. This case report suggests (1) AF could be a promising diagnostic for post-infectious illness, (2) AF can be used to test effective treatments for post-infectious illness, and (3) individualized PEMF may resolve post-infectious symptoms. Frontiers Media S.A. 2023-01-11 /pmc/articles/PMC9874300/ /pubmed/36714125 http://dx.doi.org/10.3389/fmed.2022.879971 Text en Copyright © 2023 Schaefer and Bittmann. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Medicine
Schaefer, Laura V.
Bittmann, Frank N.
Case report: Individualized pulsed electromagnetic field therapy in a Long COVID patient using the Adaptive Force as biomarker
title Case report: Individualized pulsed electromagnetic field therapy in a Long COVID patient using the Adaptive Force as biomarker
title_full Case report: Individualized pulsed electromagnetic field therapy in a Long COVID patient using the Adaptive Force as biomarker
title_fullStr Case report: Individualized pulsed electromagnetic field therapy in a Long COVID patient using the Adaptive Force as biomarker
title_full_unstemmed Case report: Individualized pulsed electromagnetic field therapy in a Long COVID patient using the Adaptive Force as biomarker
title_short Case report: Individualized pulsed electromagnetic field therapy in a Long COVID patient using the Adaptive Force as biomarker
title_sort case report: individualized pulsed electromagnetic field therapy in a long covid patient using the adaptive force as biomarker
topic Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9874300/
https://www.ncbi.nlm.nih.gov/pubmed/36714125
http://dx.doi.org/10.3389/fmed.2022.879971
work_keys_str_mv AT schaeferlaurav casereportindividualizedpulsedelectromagneticfieldtherapyinalongcovidpatientusingtheadaptiveforceasbiomarker
AT bittmannfrankn casereportindividualizedpulsedelectromagneticfieldtherapyinalongcovidpatientusingtheadaptiveforceasbiomarker