Cargando…

Apnoeic oxygenation in morbid obesity: a randomised controlled trial comparing facemask and high-flow nasal oxygen delivery

BACKGROUND: Obesity is a risk factor for airway-related incidents during anaesthesia. High-flow nasal oxygen has been advocated to improve safety in high-risk groups, but its effectiveness in the obese population is uncertain. This study compared the effect of high-flow nasal oxygen and low-flow fac...

Descripción completa

Detalles Bibliográficos
Autores principales: Schutzer-Weissmann, John, Wojcikiewicz, Thomas, Karmali, Anil, Lukosiute, Asta, Sun, Ruoyi, Kanji, Rafiq, Ahmed, Ahmed R., Purkayastha, Sanjay, Brett, Stephen J., Cousins, Jonathan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9875910/
https://www.ncbi.nlm.nih.gov/pubmed/35027169
http://dx.doi.org/10.1016/j.bja.2021.12.011
Descripción
Sumario:BACKGROUND: Obesity is a risk factor for airway-related incidents during anaesthesia. High-flow nasal oxygen has been advocated to improve safety in high-risk groups, but its effectiveness in the obese population is uncertain. This study compared the effect of high-flow nasal oxygen and low-flow facemask oxygen delivery on duration of apnoea in morbidly obese patients. METHODS: Morbidly obese patients undergoing bariatric surgery were randomly allocated to receive either high-flow nasal (70 L min(−1)) or facemask (15 L min(−1)) oxygen. After induction of anaesthesia, the patients were apnoeic for 18 min or until peripheral oxygen saturation decreased to 92%. RESULTS: Eighty patients were studied (41 High-Flow Nasal Oxygen, 39 Facemask). The median apnoea time was 18 min in both the High-Flow Nasal Oxygen (IQR 18–18 min) and the Facemask (inter-quartile range [IQR], 4.1–18 min) groups. Five patients in the High-Flow Nasal Oxygen group and 14 patients in the Facemask group desaturated to 92% within 18 min. The risk of desaturation was significantly lower in the High-Flow Nasal Oxygen group (hazard ratio=0.27; 95% confidence interval [CI], 0.11–0.65; P=0.007). CONCLUSIONS: In experienced hands, apnoeic oxygenation is possible in morbidly obese patients, and oxygen desaturation did not occur for 18 min in the majority of patients, whether oxygen delivery was high-flow nasal or low-flow facemask. High-flow nasal oxygen may reduce desaturation risk compared with facemask oxygen. Desaturation risk is a more clinically relevant outcome than duration of apnoea. Individual physiological factors are likely to be the primary determinant of risk rather than method of oxygen delivery. CLINICAL TRIAL REGISTRATION: NCT03428256.