Cargando…
TiRobot-assisted percutaneous kyphoplasty in the management of multilevel (more than three levels) osteoporotic vertebral compression fracture
PURPOSE: To compare the effectiveness of TiRobot-assisted kyphoplasty with that of the traditional fluoroscopy-assisted approach in treating multilevel osteoporotic vertebral compression fractures. METHODS: In this retrospective study, we collected data from 71 patients (TiRobot-assisted group, n = ...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2022
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9877043/ https://www.ncbi.nlm.nih.gov/pubmed/36102979 http://dx.doi.org/10.1007/s00264-022-05580-1 |
_version_ | 1784878299828191232 |
---|---|
author | Lin, Shu Tang, Liu-yi Wang, Fei Yuan, Xin-wei Hu, Jiang Liang, Wei-min |
author_facet | Lin, Shu Tang, Liu-yi Wang, Fei Yuan, Xin-wei Hu, Jiang Liang, Wei-min |
author_sort | Lin, Shu |
collection | PubMed |
description | PURPOSE: To compare the effectiveness of TiRobot-assisted kyphoplasty with that of the traditional fluoroscopy-assisted approach in treating multilevel osteoporotic vertebral compression fractures. METHODS: In this retrospective study, we collected data from 71 patients (TiRobot-assisted group, n = 39; fluoroscopy-assisted group, n = 32) with multilevel osteoporotic vertebral compression fracture treated with unilateral traditional TiRobot-assisted or fluoroscopy-assisted percutaneous kyphoplasty. The operative time, infusion volume, length of stay (LOS), hospital expenses, visual analog scale (VAS), Oswestry Disability Index (ODI), radiation exposure, puncture deviation, anterior height of diseased vertebrae, local kyphotic angle, bone cement distribution, and bone cement leakage were compared between the TiRobot- and fluoroscopy-assisted groups. RESULTS: Of the 257 treated vertebrae, the average amount of bone cement injected in the TiRobot-assisted (142 vertebrae) and fluoroscopy-assisted (115 vertebrae) groups was 4.6 mL and 4.5 mL, respectively. The VAS score was significantly lower in the TiRobot-assisted group at 24 hours post-operatively (p = 0.006). The X-ray frequency was 34.7 times in the TiRobot-assisted group and 51.7 times in the fluoroscopy-assisted group (p < 0.001). In addition to the operative time, cumulative radiation dose for the surgeon and patient was significantly lower in the TiRobot-assisted group. The hospital expenses of the TiRobot-assisted group were significantly higher (p < 0.001). The puncture deviation and bone cement distribution were better in the TiRobot-assisted group (p < 0.001). Bone cement leakage was found in 18 and 29 cases in the TiRobot- and fluoroscopy-assisted groups, respectively (p = 0.010). One patient in the fluoroscopy-assisted group experienced radiculopathy due to a misplaced puncture but recovered in three months. No radiculopathy was observed in the TiRobot-assisted group. CONCLUSIONS: TiRobot-assisted percutaneous multilevel kyphoplasty is more accurate and has smaller radiometry, a more uniform bone cement distribution, and lower bone cement leakage. This method was therefore accurate and safe. |
format | Online Article Text |
id | pubmed-9877043 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2022 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-98770432023-01-27 TiRobot-assisted percutaneous kyphoplasty in the management of multilevel (more than three levels) osteoporotic vertebral compression fracture Lin, Shu Tang, Liu-yi Wang, Fei Yuan, Xin-wei Hu, Jiang Liang, Wei-min Int Orthop Original Paper PURPOSE: To compare the effectiveness of TiRobot-assisted kyphoplasty with that of the traditional fluoroscopy-assisted approach in treating multilevel osteoporotic vertebral compression fractures. METHODS: In this retrospective study, we collected data from 71 patients (TiRobot-assisted group, n = 39; fluoroscopy-assisted group, n = 32) with multilevel osteoporotic vertebral compression fracture treated with unilateral traditional TiRobot-assisted or fluoroscopy-assisted percutaneous kyphoplasty. The operative time, infusion volume, length of stay (LOS), hospital expenses, visual analog scale (VAS), Oswestry Disability Index (ODI), radiation exposure, puncture deviation, anterior height of diseased vertebrae, local kyphotic angle, bone cement distribution, and bone cement leakage were compared between the TiRobot- and fluoroscopy-assisted groups. RESULTS: Of the 257 treated vertebrae, the average amount of bone cement injected in the TiRobot-assisted (142 vertebrae) and fluoroscopy-assisted (115 vertebrae) groups was 4.6 mL and 4.5 mL, respectively. The VAS score was significantly lower in the TiRobot-assisted group at 24 hours post-operatively (p = 0.006). The X-ray frequency was 34.7 times in the TiRobot-assisted group and 51.7 times in the fluoroscopy-assisted group (p < 0.001). In addition to the operative time, cumulative radiation dose for the surgeon and patient was significantly lower in the TiRobot-assisted group. The hospital expenses of the TiRobot-assisted group were significantly higher (p < 0.001). The puncture deviation and bone cement distribution were better in the TiRobot-assisted group (p < 0.001). Bone cement leakage was found in 18 and 29 cases in the TiRobot- and fluoroscopy-assisted groups, respectively (p = 0.010). One patient in the fluoroscopy-assisted group experienced radiculopathy due to a misplaced puncture but recovered in three months. No radiculopathy was observed in the TiRobot-assisted group. CONCLUSIONS: TiRobot-assisted percutaneous multilevel kyphoplasty is more accurate and has smaller radiometry, a more uniform bone cement distribution, and lower bone cement leakage. This method was therefore accurate and safe. Springer Berlin Heidelberg 2022-09-14 2023-02 /pmc/articles/PMC9877043/ /pubmed/36102979 http://dx.doi.org/10.1007/s00264-022-05580-1 Text en © The Author(s) 2022 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Original Paper Lin, Shu Tang, Liu-yi Wang, Fei Yuan, Xin-wei Hu, Jiang Liang, Wei-min TiRobot-assisted percutaneous kyphoplasty in the management of multilevel (more than three levels) osteoporotic vertebral compression fracture |
title | TiRobot-assisted percutaneous kyphoplasty in the management of multilevel (more than three levels) osteoporotic vertebral compression fracture |
title_full | TiRobot-assisted percutaneous kyphoplasty in the management of multilevel (more than three levels) osteoporotic vertebral compression fracture |
title_fullStr | TiRobot-assisted percutaneous kyphoplasty in the management of multilevel (more than three levels) osteoporotic vertebral compression fracture |
title_full_unstemmed | TiRobot-assisted percutaneous kyphoplasty in the management of multilevel (more than three levels) osteoporotic vertebral compression fracture |
title_short | TiRobot-assisted percutaneous kyphoplasty in the management of multilevel (more than three levels) osteoporotic vertebral compression fracture |
title_sort | tirobot-assisted percutaneous kyphoplasty in the management of multilevel (more than three levels) osteoporotic vertebral compression fracture |
topic | Original Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9877043/ https://www.ncbi.nlm.nih.gov/pubmed/36102979 http://dx.doi.org/10.1007/s00264-022-05580-1 |
work_keys_str_mv | AT linshu tirobotassistedpercutaneouskyphoplastyinthemanagementofmultilevelmorethanthreelevelsosteoporoticvertebralcompressionfracture AT tangliuyi tirobotassistedpercutaneouskyphoplastyinthemanagementofmultilevelmorethanthreelevelsosteoporoticvertebralcompressionfracture AT wangfei tirobotassistedpercutaneouskyphoplastyinthemanagementofmultilevelmorethanthreelevelsosteoporoticvertebralcompressionfracture AT yuanxinwei tirobotassistedpercutaneouskyphoplastyinthemanagementofmultilevelmorethanthreelevelsosteoporoticvertebralcompressionfracture AT hujiang tirobotassistedpercutaneouskyphoplastyinthemanagementofmultilevelmorethanthreelevelsosteoporoticvertebralcompressionfracture AT liangweimin tirobotassistedpercutaneouskyphoplastyinthemanagementofmultilevelmorethanthreelevelsosteoporoticvertebralcompressionfracture |